Slice-to-Volume Nonrigid Registration of Histological Sections to MR Images of the Human Brain
Open accessThe DOI matches its Crossref record.
Abstract
Registration of histological images to three-dimensional imaging modalities is an important step in quantitative analysis of brain structure, in architectonic mapping of the brain, and in investigation of the pathology of a brain disease. Reconstruction of histology volume from serial sections is a well-established procedure, but it does not address registration of individual slices from sparse sections, which is the aim of the slice-to-volume approach. This study presents a flexible framework for intensity-based slice-to-volume nonrigid registration algorithms with a geometric transformation deformation field parametrized by various classes of spline functions: thin-plate splines (TPS), Gaussian elastic body splines (GEBS), or cubic B-splines. Algorithms are applied to cross-modality registration of histological and magnetic resonance images of the human brain. Registration performance is evaluated across a range of optimization algorithms and intensity-based cost functions. For a particular case of histological data, best results are obtained with a TPS three-dimensional (3D) warp, a new unconstrained optimization algorithm (NEWUOA), and a correlation-coefficient-based cost function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
“…from a single histological slice is used alone and its content may be hard to handle by itself (see § 2 and 3) in a multi-modal registration problem: the performance of slice-to-volume registration shows greater dependence on the input images than 3D-3D registration (Osechinskiy and Kruggel, 2010).”
BackgroundMethodInfluentialSlice-to-volume medical image registration: A survey
Ferrante, E., & Paragios, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.04.010 · Cited by 182
“(Elen et al., 2010; Osechinskiy and Kruggel, 2011b) have applied this strategy to estimate rigid and non-rigid slice-to-volume mapping functions, respectively.”
BackgroundMethodInfluential3D reconstruction of medical images from slices automatically landmarked with growing neural models
Angelopoulou, A., Psarrou, A., Garcia-Rodriguez, J., Orts-Escolano, S., Azorin-Lopez, J., & Revett, K. (2015) · Neurocomputing · doi:10.1016/j.neucom.2014.03.078 · Cited by 31
Huszar, I. N., Pallebage-Gamarallage, M., Foxley, S., Tendler, B. C., Leonte, A., Hiemstra, M., Mollink, J., Smart, A., Bangerter-Christensen, S., Brooks, H., et al. (2019) · doi:10.1101/849570 · Cited by 11
Metadata
- Authors
- Osechinskiy, S., & Kruggel, F.
- Venue
- Anatomy Research International
- Publisher
- Hindawi Limited
- Published
- 2011-12-12
- Volume
- 2011
- Pages
- 1-17
- ISSN
- 2090-2743 (ISSN-L)
- 2090-2751
- OpenAlex
- W2163751498
- Cited by
- 39
- References
- 0
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.