Canadian Prediction Equations of Spirometric Lung Function for Caucasian Adults 20 to 90 Years of Age: Results from the Canadian Obstructive Lung Disease (COLD) Study and the Lung Health Canadian Environment (LHCE) Study
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Currently, no reference or normative values for spirometry based on a randomly selected Canadian population exist. OBJECTIVE: The aim of the present analysis was to construct spirometric reference values for Canadian adults 20 to 90 years of age by combining data collected from healthy lifelong nonsmokers in two population‐based studies. METHOD: Both studies similarly used random population sampling, conducted using validated epidemiological protocols in the Canadian Obstructive Lung Disease study, and the Lung Health Canadian Environment study. Spirometric lung function data were available from 3042 subjects in the COLD study, which was completed in 2009, and from 2571 subjects in the LHCE study completed in 1995. A total of 844 subjects 40 to 90 years of age, and 812 subjects 20 to 44 years of age, were identified as healthy, asymptomatic, lifelong nonsmokers, and provided normative reference values for spirometry. Multiple regression models were constructed separately for Caucasian men and women for the following spirometric parameters: forced expiratory volume in 1 s (FEV 1), forced vital capacity (FVC) and FEV 1/FVC ratio, with covariates of height, sex and age. Comparison with published regression equations showed that the best agreement was obtained from data derived from random populations. RESULTS: The best‐fitting regression models for healthy, never‐smoking, asymptomatic European‐Canadian men and women 20 to 90 years of age were constructed. When age‐ and height‐corrected FEV 1, FVC and FEV 1/FVC ratio were compared with other spirometry reference studies, mean values were similar, with the closest being derived from population‐based studies. CONCLUSION: These spirometry reference equations, derived from randomly selected population‐based cohorts with stringently monitored lung function measurements, provide data currently lacking in Canada.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Changes in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907
Cited by
Sex differences in large conducting airway anatomy
Dominelli, P. B., Ripoll, J. G., Cross, T. J., Baker, S. E., Wiggins, C. C., Welch, B. T., & Joyner, M. J. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00440.2018 · Cited by 158
Ramsook, A. H., Molgat-Seon, Y., Schaeffer, M. R., Wilkie, S. S., Camp, P. G., Reid, W. D., Romer, L. M., & Guenette, J. A. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00046.2017 · Cited by 70
Metadata
- Authors
- Tan, W., Bourbeau, J., Hernandez, P., Chapman, K., Cowie, R., FitzGerald, M., Aaron, S., Marciniuk, D., Maltais, F., O’Donnell, D., Goldstein, R., Sin, D., Chan-Yeung, M., Manfreda, J., Anthonisen, N., Tate, R., Sears, M., Siersted, H., Becklake, M., Ernst, P., Bowie, D., Sweet, L., & Van Til, L.
- Venue
- Canadian Respiratory Journal
- Publisher
- Wiley
- Published
- 2011-01
- Volume
- 18
- Issue
- 6
- Pages
- 321-326
- ISSN
- 1198-2241 (ISSN-L)
- 1916-7245
- OpenAlex
- W2293513381
- Cited by
- 62
- References
- 2
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.