Physical Activity Recognition Utilizing the Built-In Kinematic Sensors of a Smartphone
Open accessThe DOI matches its Crossref record.
Abstract
Physical activity (PA) recognition has recently become important in activity monitoring for the public healthcare. Although body-worn sensors are well suited to collect data on activity patterns for long periods of time, users may forget to wear special microsensors. On the contrary, more and more people take smartphone with them almost anytime. At present, most popular smartphones have three built-in kinematic sensors (triaccelerometer, gyroscope, and magnetic sensor) which could be utilized to recognize PA. This study utilized three built-in kinematic sensors in a smartphone to recognize PA and found out which features derived from the three sensors were significant to different PA. We used a combined algorithm of Fisher's discriminant ratio criterion and [Formula: see text] criterion for feature selection. A hierarchical classifiers system including fourteen classifiers was proposed and employed to recognize fifteen activities. The optimal features derived from the built-in kinematic sensors of the smartphone were selected from 140 features. The results indicated that the accelerometer was significant to PA recognition, while gyroscope and orientation sensor were effective to recognize the change of body posture and detect falls, respectively. The total classification accuracy of 95.03% demonstrated the feasibility of utilizing the built-in kinematic sensors of the smartphone to recognize PA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measuring and Influencing Physical Activity with Smartphone Technology: A Systematic Review
Bort-Roig, J., Gilson, N. D., Puig-Ribera, A., Contreras, R. S., & Trost, S. G. (2014) · Sports Medicine · doi:10.1007/s40279-014-0142-5 · Cited by 557
Nweke, H. F., Teh, Y. W., Mujtaba, G., & Al-garadi, M. A. (2019) · Information Fusion · doi:10.1016/j.inffus.2018.06.002 · Cited by 394
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Ponzo, S., Morelli, D., Kawadler, J. M., Hemmings, N. R., Bird, G., & Plans, D. (2020) · JMIR mHealth and uHealth · doi:10.2196/17767 · Cited by 100
Online human activity recognition using low-power wearable devices
Bhat, G., Deb, R., Chaurasia, V. V., Shill, H., & Ogras, U. Y. (2018) · Proceedings of the International Conference on Computer-Aided Design · doi:10.1145/3240765.3240833 · Cited by 82
“Therefore, recent work on HAR has focused on implementation on smartphones [3, 8, 17, 31].”
Background
Metadata
- Authors
- He, Y., & Li, Y.
- Venue
- International Journal of Distributed Sensor Networks
- Publisher
- SAGE Publications
- Published
- 2013-04-01
- Volume
- 9
- Issue
- 4
- Pages
- 481580
- ISSN
- 1550-1329 (ISSN-L)
- 1550-1477
- OpenAlex
- W2060663350
- Cited by
- 103
- References
- 0
- FWCI
- 17.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical Activity Recognition Utilizing the Built-In Kinematic Sensors of a Smartphone. https://app.cochat.ai/papers/10.1155/2013/481580
- The paper
- He, Y., & Li, Y. (2013). Physical Activity Recognition Utilizing the Built-In Kinematic Sensors of a Smartphone. International Journal of Distributed Sensor Networks. https://doi.org/10.1155/2013/481580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.