Effect of W/C Ratio on Durability and Porosity in Cement Mortar with Constant Cement Amount
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Water is often added to concrete placing for easy workability and finishability in construction site. The additional mixing water can help easy mixing and workability but causes increased porosity, which yields degradation of durability and structural performances. In this paper, cement mortar samples with 0.45 of W/C (water to cement) ratio are prepared for control case and durability performances are evaluated with additional water from 0.45 to 0.60 of W/C. Several durability tests including strength, chloride diffusion, air permeability, saturation, and moisture diffusion are performed, and they are analyzed with changed porosity. The changing ratios and patterns of durability performance are evaluated considering pore size distribution, total porosity, and additional water content.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neville, A. M. (1968) · Virtual Defense Library (Ministerio de Defensa) · Cited by 5,444
Concrete: Structure, properties and materials
(1986) · International Journal of Cement Composites and Lightweight Concrete · doi:10.1016/0262-5075(86)90055-2 · Cited by 1,350
Chloride binding capacity and binding isotherms of OPC pastes and mortars
Luping, T., & Nilsson, L.-O. (1993) · Cement and Concrete Research · doi:10.1016/0008-8846(93)90089-r · Cited by 781 · cited 1×
“samples with the same porosities, they may have different chloride diffusion coefficients due to the enhanced binding capacity in concrete with mineral admixture [17, 21].”
BackgroundFundamental Modeling and Experimental Investigation of Concrete Carbonation
(1991) · ACI Materials Journal · doi:10.14359/1863 · Cited by 598 · cited 2×
“For carbonation, the porosity is altered with carbonation process due to the formation of CaCO 3 [14, 15, 22, 23].”
BackgroundMethodEFFECTS OF CARBONATION ON PORE STRUCTURE AND DIFFUSIONAL PROPERTIES OF HYDRATED CEMENT PASTES
Ngala, V. T., & Page, C. L. (1997) · Cement and Concrete Research · doi:10.1016/s0008-8846(97)00102-6 · Cited by 557 · cited 1×
“Many researches have been performed on the effects of curing condition, type of mix proportions, and mineral admixtures on the related porosity [5–8]; however, they have shown a qualitative evaluation for porosity without reliable explanation for the relationship between porosity and durability performance.”
BackgroundPermeability characteristics of carbonated concrete considering capillary pore structure
Song, H.-W., & Kwon, S.-J. (2007) · Cement and Concrete Research · doi:10.1016/j.cemconres.2007.03.011 · Cited by 301 · cited 1×
“Porosity changes and its relationship with air/water permeability are also investigated [16–19].”
BackgroundSelf-citationIshida, T., Maekawa, K., & Kishi, T. (2006) · Cement and Concrete Research · doi:10.1016/j.cemconres.2006.11.015 · Cited by 256
Study on some factors affecting the results in the use of MIP method in concrete research
Kumar, R., & Bhattacharjee, B. (2003) · Cement and Concrete Research · doi:10.1016/s0008-8846(02)00974-2 · Cited by 237 · cited 1×
“MIP test is conventionally performed for its convenience and reliable results for capillary pores [26, 27].”
BackgroundPredicting carbonation in early-aged cracked concrete
Song, H.-W., Kwon, S.-J., Byun, K.-J., & Park, C.-K. (2006) · Cement and Concrete Research · doi:10.1016/j.cemconres.2005.12.019 · Cited by 197 · cited 1×
“For carbonation, the porosity is altered with carbonation process due to the formation of CaCO 3 [14, 15, 22, 23].”
BackgroundSelf-citationAnalysis of carbonation behavior in concrete using neural network algorithm and carbonation modeling
Kwon, S.-J., & Song, H.-W. (2009) · Cement and Concrete Research · doi:10.1016/j.cemconres.2009.08.022 · Cited by 127
Self-citationMODELING OF PH PROFILE IN PORE WATER BASED ON MASS TRANSPORT AND CHEMICAL EQUILIBRIUM THEORY
Ishida, T., & Maekawa, K. (2000) · Doboku Gakkai Ronbunshu · doi:10.2208/jscej.2000.648_203 · Cited by 83 · cited 1×
“For deterioration analysis considering porosity changes, many researches have been carried out for chloride diffusion mechanism [1, 12, 13] and carbonation behavior [2, 4, 14, 15].”
MethodAnalysis of Moisture Transport in Mortars and Concrete Using Sorption-Diffusion Approach
Neithalath, N. (2006) · ACI Materials Journal · doi:10.14359/15855 · Cited by 77 · cited 2×
“diffusion is proposed considering mass of diffusion and sorption like the following [36]:”
Background
Cited by
Lyngdoh, G. A., Zaki, M., Krishnan, N. M. A., & Das, S. (2022) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2022.104414 · Cited by 218
“This can be explained by the fact that the high water to cement ratio is often connected to high porosity due to the high volume of voids that are not filled by hydration products [81,82].”
Background
Metadata
- Authors
- Kim, Y.-Y., Lee, K.-M., Bang, J.-W., & Kwon, S.-J.
- Venue
- Advances in Materials Science and Engineering
- Publisher
- Wiley
- Published
- 2014
- Volume
- 2014
- Pages
- 1-11
- ISSN
- 1687-8434 (ISSN-L)
- 1687-8442
- OpenAlex
- W2015537685
- Cited by
- 225
- References
- 12
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.