CoChat

Higher Effective Oronasal versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: Effect of Mandibular Stabilization

Open access
Kaminska, M, Montpetit, A, Mathieu, A, Jobin, V, Morisson, F, Mayer, P · 2014 · Canadian Respiratory Journal
Cited by 41

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: In some individuals with obstructive sleep apnea (OSA), oronasal continuous positive airway pressure (CPAP) leads to poorer OSA correction than nasal CPAP. The authors hypothesized that this results from posterior mandibular displacement caused by the oronasal mask. OBJECTIVE: To test this hypothesis using a mandibular advancement device (MAD) for mandibular stabilization. METHODS: Subjects whose OSA was not adequately corrected by oronasal CPAP at pressures for which nasal CPAP was effective were identified. These subjects underwent polysomnography (PSG) CPAP titration with each nasal and oronasal mask consecutively, with esophageal pressure and leak monitoring, to obtain the effective pressure (Peff) of CPAP for correcting obstructive events with each mask (maximum 20 cmH 2 O). PSG titration was repeated using a MAD in the neutral position. Cephalometry was performed. RESULTS: Six subjects with mean (± SD) nasal Peff 10.4±3.0 cmH 2 O were studied. Oronasal Peff was greater than nasal Peff in all subjects, with obstructive events persisting at 20 cmH 2 O by oronasal mask in four cases. This was not due to excessive leak. With the MAD, oronasal Peff was reduced in three subjects, and Peff <20 cmH 2 O could be obtained in two of the four subjects with Peff >20 cmH 2 O by oronasal mask alone. Subjects’ cephalometric variables were similar to published norms. CONCLUSION: In subjects with OSA with higher oronasal than nasal Peff, this is partially explained by posterior mandibular displacement caused by the oronasal mask. Combination treatment with oronasal mask and MAD may be useful in some individuals if a nasal mask is not tolerated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2014/408073

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 41

Metadata

Authors
Kaminska, M., Montpetit, A., Mathieu, A., Jobin, V, Morisson, F., & Mayer, P.
Venue
Canadian Respiratory Journal
Publisher
Wiley
Published
2014-01
Volume
21
Issue
4
Pages
234-238
ISSN
  • 1198-2241 (ISSN-L)
  • 1916-7245
OpenAlex
W2255125876
Cited by
41
References
8
FWCI
3.30
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Higher Effective Oronasal versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: Effect of Mandibular Stabilization. https://app.cochat.ai/papers/10.1155/2014/408073
The paper
Kaminska, M., Montpetit, A., Mathieu, A., Jobin, V, Morisson, F., & Mayer, P. (2014). Higher Effective Oronasal versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: Effect of Mandibular Stabilization. Canadian Respiratory Journal. https://doi.org/10.1155/2014/408073

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.