The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
Open accessAbstract
Characterizing fetal wellbeing with a Doppler ultrasound device requires computation of a score based on fetal parameters. In order to analyze the parameters derived from the fetal heart rate correctly, an accuracy of 0.25 beats per minute is needed. Simultaneously with the lowest false negative rate and the highest sensitivity, we investigated whether various Doppler techniques ensure this accuracy. We found that the accuracy was ensured if directional Doppler signals and autocorrelation estimation were used. Our best estimator provided sensitivity of 95.5%, corresponding to an improvement of 14% compared to the standard estimator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
Cited by
A deep learning approach for Parkinson’s disease diagnosis from EEG signals
Oh, S. L., Hagiwara, Y., Raghavendra, U., Yuvaraj, R., Arunkumar, N., Murugappan, M., & Acharya, U. R. (2020) · Neural Computing and Applications · doi:10.1007/s00521-018-3689-5 · Cited by 627
Behavioural change models for infectious disease transmission: a systematic review (2010–2015)
Verelst, F., Willem, L., & Beutels, P. (2016) · Journal of The Royal Society Interface · doi:10.1098/rsif.2016.0820 · Cited by 382
Increasing trend of wearables and multimodal interface for human activity monitoring: A review
Kumari, P., Mathew, L., & Syal, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.001 · Cited by 298
Assessing the complexity of short-term heartbeat interval series by distribution entropy
Li, P., Liu, C., Li, K., Zheng, D., Liu, C., & Hou, Y. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1216-0 · Cited by 260
Marucci, M., Di Flumeri, G., Borghini, G., Sciaraffa, N., Scandola, M., Pavone, E. F., Babiloni, F., Betti, V., & Aricò, P. (2021) · Scientific Reports · doi:10.1038/s41598-021-84196-8 · Cited by 170
Metadata
- Authors
- Voicu, I., Ménigot, S., Kouamé, D., & Girault, J.-M.
- Venue
- Computational and Mathematical Methods in Medicine
- Publisher
- Wiley
- Published
- 2014
- Volume
- 2014
- Pages
- 1-10
- ISSN
- 1748-670X (ISSN-L)
- 1748-6718
- OpenAlex
- W2020108261
- Cited by
- 187
- References
- 1
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices. https://app.cochat.ai/papers/10.1155/2014/784862
- The paper
- Voicu, I., Ménigot, S., Kouamé, D., & Girault, J.-M. (2014). New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices. Computational and Mathematical Methods in Medicine. https://doi.org/10.1155/2014/784862
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.