Applying an Open-Source Segmentation Algorithm to Different OCT Devices in Multiple Sclerosis Patients and Healthy Controls: Implications for Clinical Trials
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background. The lack of segmentation algorithms operative across optical coherence tomography (OCT) platforms hinders utility of retinal layer measures in MS trials.Objective. To determine cross-sectional and longitudinal agreement of retinal layer thicknesses derived from an open-source, fully-automated, segmentation algorithm, applied to two spectral-domain OCT devices.Methods. Cirrus HD-OCT and Spectralis OCT macular scans from 68 MS patients and 22 healthy controls were segmented. A longitudinal cohort comprising 51 subjects (mean follow-up: 1.4 ± 0.9 years) was also examined. Bland-Altman analyses and interscanner agreement indices were utilized to assess agreement between scanners.Results. Low mean differences (−2.16 to 0.26 μ m) and narrow limits of agreement (LOA) were noted for ganglion cell and inner and outer nuclear layer thicknesses cross-sectionally. Longitudinally we found low mean differences (−0.195 to 0.21 μ m) for changes in all layers, with wider LOA. Comparisons of rate of change in layer thicknesses over time revealed consistent results between the platforms.Conclusions. Retinal thickness measures for the majority of the retinal layers agree well cross-sectionally and longitudinally between the two scanners at the cohort level, with greater variability at the individual level. This open-source segmentation algorithm enables combining data from different OCT platforms, broadening utilization of OCT as an outcome measure in MS trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065 · cited 1×
“For the longitudinal cohort we performed modified Bland-Altman analysis to adjust for repeated measures, utilizing the change in various retinal layers between serial scans [32].”
Method
Cited by
Nolan‐Kenney, R. C., Liu, M., Akhand, O., Calabresi, P. A., Paul, F., Petzold, A., Balk, L., Brandt, A. U., Martínez‐Lapiscina, E. H., Saidha, S., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25462 · Cited by 164
Self-citationStructured layer surface segmentation for retina OCT using fully convolutional regression networks
He, Y., Carass, A., Liu, Y., Jedynak, B. M., Solomon, S. D., Saidha, S., Calabresi, P. A., & Prince, J. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101856 · Cited by 104
“The AURA toolkit (Lang et al., 2013) is a graph based method and it is the state-of-the-art compared to other publicly available tools, as shown in Bhargava et al. (2015); Tian et al. (2016).”
MethodSelf-citationHe, Y., Carass, A., Solomon, S. D., Saidha, S., Calabresi, P. A., & Prince, J. L. (2019) · Data in Brief · doi:10.1016/j.dib.2018.12.073 · Cited by 90
Self-citation
Metadata
- Authors
- Bhargava, P., Lang, A., Al-Louzi, O., Carass, A., Prince, J., Calabresi, P. A., & Saidha, S.
- Venue
- Multiple Sclerosis International
- Publisher
- Wiley
- Published
- 2015
- Volume
- 2015
- Pages
- 1-10
- ISSN
- 2090-2654 (ISSN-L)
- 2090-2662
- OpenAlex
- W1585505746
- Cited by
- 45
- References
- 3
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.