The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nonintrusive Load Monitoring Based on Advanced Deep Learning and Novel Signature
Open accessAbstract
Monitoring electricity consumption in the home is an important way to help reduce energy usage. Nonintrusive Load Monitoring (NILM) is existing technique which helps us monitor electricity consumption effectively and costly. NILM is a promising approach to obtain estimates of the electrical power consumption of individual appliances from aggregate measurements of voltage and/or current in the distribution system. Among the previous studies, Hidden Markov Model (HMM) based models have been studied very much. However, increasing appliances, multistate of appliances, and similar power consumption of appliances are three big issues in NILM recently. In this paper, we address these problems through providing our contributions as follows. First, we proposed state-of-the-art energy disaggregation based on Long Short-Term Memory Recurrent Neural Network (LSTM-RNN) model and additional advanced deep learning. Second, we proposed a novel signature to improve classification performance of the proposed model in multistate appliance case. We applied the proposed model on two datasets such as UK-DALE and REDD. Via our experimental results, we have confirmed that our model outperforms the advanced model. Thus, we show that our combination between advanced deep learning and novel signature can be a robust solution to overcome NILM’s issues and improve the performance of load identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Cyber-Physical Systems architecture for Industry 4.0-based manufacturing systems
Lee, J., Bagheri, B., & Kao, H.-A. (2015) · Manufacturing Letters · doi:10.1016/j.mfglet.2014.12.001 · Cited by 5,113
Cited by
State of the Art of Machine Learning Models in Energy Systems, a Systematic Review
Mosavi, A., Salimi, M., Faizollahzadeh Ardabili, S., Rabczuk, T., Shamshirband, S., & Varkonyi-Koczy, A. R. (2019) · Energies · doi:10.3390/en12071301 · Cited by 578
Transfer Learning for Non-Intrusive Load Monitoring
D'Incecco, M., Squartini, S., & Zhong, M. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2938068 · Cited by 330
NILM Techniques for Intelligent Home Energy Management and Ambient Assisted Living: A Review
Ruano, A., Hernandez, A., Ureña, J., Ruano, M., & Garcia, J. (2019) · Energies · doi:10.3390/en12112203 · Cited by 271
Metadata
- Authors
- Kim, J., Le, T.-T.-H., & Kim, H.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Wiley
- Published
- 2017
- Volume
- 2017
- Pages
- 1-22
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W2761004327
- Cited by
- 160
- References
- 1
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonintrusive Load Monitoring Based on Advanced Deep Learning and Novel Signature. https://app.cochat.ai/papers/10.1155/2017/4216281
- The paper
- Kim, J., Le, T.-T.-H., & Kim, H. (2017). Nonintrusive Load Monitoring Based on Advanced Deep Learning and Novel Signature. Computational Intelligence and Neuroscience. https://doi.org/10.1155/2017/4216281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.