Comparison of Machine-Learning Classification Models for Glaucoma Management
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study develops an objective machine-learning classification model for classifying glaucomatous optic discs and reveals the classificatory criteria to assist in clinical glaucoma management. In this study, 163 glaucoma eyes were labelled with four optic disc types by three glaucoma specialists and then randomly separated into training and test data. All the images of these eyes were captured using optical coherence tomography and laser speckle flowgraphy to quantify the ocular structure and blood-flow-related parameters. A total of 91 parameters were extracted from each eye along with the patients’ background information. Machine-learning classifiers, including the neural network (NN), naïve Bayes (NB), support vector machine (SVM), and gradient boosted decision trees (GBDT), were trained to build the classification models, and a hybrid feature selection method that combines minimum redundancy maximum relevance and genetic-algorithm-based feature selection was applied to find the most valid and relevant features for NN, NB, and SVM. A comparison of the performance of the three machine-learning classification models showed that the NN had the best classification performance with a validated accuracy of 87.8% using only nine ocular parameters. These selected quantified parameters enabled the trained NN to classify glaucomatous optic discs with relatively high performance without requiring color fundus images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Ocular Blood Flow and Influencing Factors for Glaucoma
Nakazawa, T. (2016) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000183 · Cited by 129 · cited 1×
“Besides intraocular pressure, which is an evidenced and treatable influencing factor, glaucoma is considered to be a multifactorial disease; some of these factors are myopia, ocular blood flow, and oxidative stress [1].”
BackgroundSelf-citation
Research works printed but not linked: 16
- 10.1016/s0161-6420(96)30640-4 · doi:10.1016/s0161-6420(96)30640-4
- 10.1007/s10384-015-0379-z · doi:10.1007/s10384-015-0379-z
- 10.1097/ijg.0b013e3182182897 · doi:10.1097/ijg.0b013e3182182897
- 10.2147/opth.s22097 · doi:10.2147/opth.s22097
- 10.1371/journal.pone.0177726 · DOI · Paper page
- 10.1109/tbme.2002.802012 · DOI · Paper page
- 10.1111/j.1755-3768.2009.01784.x · doi:10.1111/j.1755-3768.2009.01784.x
- 10.1167/iovs.04-1107 · doi:10.1167/iovs.04-1107
- 10.1371/journal.pone.0160226 · DOI
- 10.1371/journal.pone.0190012 · DOI
- 10.1364/OE.18.021293 · DOI · Paper page
- 10.1109/tpami.2005.159 · DOI · Paper page
- 10.1109/5254.671091 · DOI · Paper page
- 10.1007/s10115-010-0288-x · DOI · Paper page
- 10.1364/boe.8.003440 · DOI · Paper page
- 10.1097/icu.0000000000000470 · DOI · Paper page
Cited by
Huang, S.-C., Pareek, A., Seyyedi, S., Banerjee, I., & Lungren, M. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00341-z · Cited by 934
Integrated multimodal artificial intelligence framework for healthcare applications
Soenksen, L. R., Ma, Y., Zeng, C., Boussioux, L., Villalobos Carballo, K., Na, L., Wiberg, H. M., Li, M. L., Fuentes, I., & Bertsimas, D. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00689-4 · Cited by 380
“…10 , gastroenterology 11 , gynecology 12 , hematology 13 , immunology 14 , nephrology 15 , neurology 16,17 , oncology 18 – 20 , ophthalmology 21 , psychiatry 22 , radiology 23 – 25 , public health 26 and healthcare operational analytics (i.e., mortality, length-of-stay, and discharge…”
Huang, S.-C., Pareek, A., Zamanian, R., Banerjee, I., & Lungren, M. P. (2020) · Scientific Reports · doi:10.1038/s41598-020-78888-w · Cited by 246
Metadata
- Authors
- An, G., Omodaka, K., Tsuda, S., Shiga, Y., Takada, N., Kikawa, T., Nakazawa, T., Yokota, H., & Akiba, M.
- Venue
- Journal of Healthcare Engineering
- Publisher
- Wiley
- Published
- 2018-06-19
- Volume
- 2018
- Pages
- 1-8
- ISSN
- 2040-2295 (ISSN-L)
- 2040-2309
- OpenAlex
- W2809387697
- Cited by
- 72
- References
- 2
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Machine-Learning Classification Models for Glaucoma Management. https://app.cochat.ai/papers/10.1155/2018/6874765
- The paper
- An, G., Omodaka, K., Tsuda, S., Shiga, Y., Takada, N., Kikawa, T., Nakazawa, T., Yokota, H., & Akiba, M. (2018). Comparison of Machine-Learning Classification Models for Glaucoma Management. Journal of Healthcare Engineering. https://doi.org/10.1155/2018/6874765
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.