Pilot Ex Vivo and In Vitro Evaluation of a Novel Foley Catheter with Antimicrobial Periurethral Irrigation for Prevention of Extraluminal Biofilm Colonization Leading to Catheter-Associated Urinary Tract Infections (CAUTIs)
The DOI matches its Crossref record.
Abstract
CAUTI remains a serious healthcare issue for incontinent patients whose urine drainage is managed by catheters. A novel double-balloon Foley catheter was developed which was capable of irrigating the extraluminal catheter surfaces within the periurethral space between the urethral-bladder junction and meatus. The catheter has a retention cuff that is inflated to secure the catheter in the bladder and a novel irrigation cuff proximal to the urethral-bladder junction capable of providing periurethral irrigation from the urethral-bladder junction to the meatus. Uniform periurethral irrigation was demonstrated in an ex vivo porcine model by adding a dye to the antimicrobial urethral irrigation solution. An in vitro biofilm colonization model was adapted to study the ability of periurethral irrigation with a newly developed antimicrobial combination consisting of polygalacturonic acid + caprylic acid (PG + CAP) to prevent axial colonization of the extraluminal urethral indwelling catheter shaft by common uropathogens. The extraluminal surface of control catheters that were not irrigated formed biofilms along the entire axial urethral tract after 24 hours. Significant (p<0.001) inhibition of colonization was seen against multidrug-resistant Pseudomonas aeruginosa (PA), carbapenem-resistant Escherichia coli (EC), and carbapenem-resistant Klebsiella pneumoniae (KB). For other common uropathogens including Candida albicans (CA), Proteus mirabilis (PR), and Enterococcus faecalis (EF), a first irrigation treatment completely inhibited colonization of half of the indwelling catheter closest to the bladder and a second treatment largely disinfected the remaining intraurethral portion of the catheter towards the meatus. The novel Foley catheter and PG + CAP antimicrobial irrigant prevented biofilm colonization in an in vitro CAUTI model and merits further testing in an in vivo CAUTI prevention model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Likewise, E. coli biofilms on urethral catheters achieve maturity within 24 h, underscoring the fast formation of biofilms in clinical environments [80,81].”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [81]
In the citing paper
“Biofilm maturation often occurs over hours to days, depending upon the organism and ecological circumstances.”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [81]
In the citing paper
“The maturity period of biofilms varies across bacterial species and is affected by environmental conditions, including nutrition supply, temperature, and pH.”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [81]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 29
- 10.1128/cmr.00019-07 · DOI · Paper page
- 10.1016/0002-9343(91)90345-x · DOI · Paper page
- 10.1001/archinte.160.5.678 · DOI · Paper page
- 10.1086/651091 · DOI · Paper page
- 10.4065/74.2.131 · DOI · Paper page
- 10.1086/502241 · DOI
- 10.7860/jcdr/2016/20486.7939 · doi:10.7860/jcdr/2016/20486.7939
- 10.1097/ju.0000000000000492 · DOI
- 10.3389/fmicb.2017.01999 · DOI
- 10.1177/0954411918774348 · doi:10.1177/0954411918774348
- 10.1089/end.2005.19.1016 · doi:10.1089/end.2005.19.1016
- 10.1016/0090-4295(92)90380-f · doi:10.1016/0090-4295(92)90380-f
- 2003, European Radiology, 13, 536, 10.1007/s00330-002-1539-3 · doi:10.1007/s00330-002-1539-3
- 10.1177/1757177408098265 · DOI
- 10.1016/j.ajic.2010.08.003 · doi:10.1016/j.ajic.2010.08.003
- 2013, Silpakorn University Journal, 3, 22
- 10.1016/j.ajic.2017.05.009 · DOI
- 10.1017/s0899823x00193845 · DOI
- 10.2340/16501977-2298 · DOI
- 10.4103/ijciis.ijciis_24_17 · doi:10.4103/ijciis.ijciis_24_17
- 10.1080/17434440.2019.1661774 · DOI
- 10.1016/j.actbio.2016.11.070 · DOI · Paper page
- 10.1002/14651858.cd004013.pub4 · DOI
- 10.1016/s1473-3099(18)30736-9 · DOI
- 10.1111/j.1464-410x.2011.10753.x · DOI
- 10.12968/bjnn.2011.7.sup5.s8 · doi:10.12968/bjnn.2011.7.sup5.s8
- 2004, The Professional Nurse, 19, 515
- 10.1007/s00240-009-0196-2 · DOI
- 10.1111/jam.14439 · DOI
Cited by
Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts
Almatroudi, A. (2025) · Biology · doi:10.3390/biology14020165 · Cited by 303
“Similarly, a study found that Salmonella enterica serotype Kentucky forms more biofilms at higher pH levels (7.0 and 8.0) than lower ones (4.0 to 6.0) [93].”
Influential
Metadata
- Authors
- Vargas-Cruz, N., Rosenblatt, J., Reitzel, R. A., Chaftari, A.-M., Hachem, R., & Raad, I.
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2019-12-24
- Volume
- 2019
- Pages
- 1-10
- ISSN
- 2314-6133
- 2314-6141
- Cited by
- 12
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.