CoChat

Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy

Open access
Voska, Michal, Zavoral, Miroslav, Grega, Tomas, Majek, Ondrej, Martinek, Jan, Tacheci, Ilja, Benes, Marek, Vojtechova, Gabriela, Drastich, Pavel, Bures, Jan, Spicak, Julius, Buckova, Barbora, Ngo, Ondrej, Suchanek, Stepan · 2019 · Gastroenterology Research and Practice
Cited by 36

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Backround. Capsule colonoscopy might present an alternative to colonoscopy for colorectal neoplasia screening. Aim. To assess the accuracy of second-generation capsule colonoscopy (CCE2) for colorectal neoplasia detection compared with conventional colonoscopy (CC). Methods. From 2011–2015, we performed a multicenter, prospective, cross-over study evaluating the use of CCE2 as a possible colorectal cancer (CRC) screening test based on the assessment of the method’s characteristics (accuracy) and safety and patient acceptance of the routine. Enrolled participants fulfilled the CRC screening population criteria if they were asymptomatic, were older than 50, and had no personal or familial history of colorectal neoplasia. The primary outcome was accuracy for the detection of polyps≥6 mm. Secondary outcomes were accuracy for all polyps, polyps≥10 mm, adenomas≥10 mm, and cancers, the quality of bowel cleansing, safety, and CCE2 acceptability by the screening population. Results. A total of 236 individuals were examined; 11 patients (5%) were excluded. Therefore, 225 subjects (95%) were considered in the intention-to-screen (ITS) group. A total of 201 patients (89%) completed both examinations successfully (per protocol group). In the ITS group, polyps were diagnosed during CC in 114 subjects (51%); polyps≥6 mm, polyps≥10 mm, and adenomas≥10 mm were diagnosed in 34 (15%), 16 (7%), and 11 (5%) patients, respectively. The sensitivity of CCE2 for polyps≥6 mm, polyps≥10 mm, and adenomas≥10 mm was 79% (95% confidence interval (CI): 62–91%), 88% (95% CI: 62–98%), and 100% (95% CI: 72–100%), respectively. Conclusion. Second-generation capsule colonoscopy is a safe, noninvasive, and sensitive method for colorectal neoplasia detection although CC remains the preferred method for considerable proportion of subjects. CCE2 may therefore be accepted as the primary screening test for colorectal cancer screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2019/5975438

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 36

Metadata

Authors
Voska, M., Zavoral, M., Grega, T., Majek, O., Martinek, J., Tacheci, I., Benes, M., Vojtechova, G., Drastich, P., Bures, J., Spicak, J., Buckova, B., Ngo, O., & Suchanek, S.
Venue
Gastroenterology Research and Practice
Publisher
Wiley
Published
2019-09-03
Volume
2019
Pages
1-8
ISSN
  • 1687-6121 (ISSN-L)
  • 1687-630X
OpenAlex
W2971594391
Cited by
36
References
2
FWCI
2.09
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy. https://app.cochat.ai/papers/10.1155/2019/5975438
The paper
Voska, M., Zavoral, M., Grega, T., Majek, O., Martinek, J., Tacheci, I., Benes, M., Vojtechova, G., Drastich, P., Bures, J., Spicak, J., Buckova, B., Ngo, O., & Suchanek, S. (2019). Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy. Gastroenterology Research and Practice. https://doi.org/10.1155/2019/5975438

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.