High Biofidelity 3D Biomodel Reconstruction from Soft and Hard Tissues (Knee), FEM, and 3D Printing: A Three‐Dimensional Methodological Proposal
Open accessThe DOI matches its Crossref record; 22 of the 24 references it cites were found in a registry or an index.
Abstract
The modelling of biological structures has allowed great advances in Engineering, Biology, and Medicine. In turn, these advances are seen from the design of footwear and sports accessories, to the design of prostheses, accessories and rehabilitation treatments. The reproduction of the various tissues has gone through an important evolution thanks to the development of computer systems and programs. However, knowledge of the medical‐biological and engineering areas continues to be required, and it involves a considerable investment of time and resources. The resulting biomodels still require great precision. The present work shows a methodology that allows to optimize computational resources and reduce elaboration time of biomodels. Through this methodology, it is possible to generate a biomodel of high biofidelity of a human knee. This biomodel is constituted by hard tissues (cortical and trabecular bones) and soft tissues (ligaments and meniscus) resulting in the modelling of the lower third of the femur, the tibial plateaus, the anterior cruciate ligament, posterior cruciate ligament, external lateral ligament, interior lateral ligaments, and the meniscus. With this model and methodology, it is possible to perform numerical analyses that will provide results very similar to those of real life. As, the methodology allows to assign the mechanical properties to each tissue and the anatomical structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures












Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The detailed development of these biomodels and their validation are widely described in [38].”
From Numerical Analysis of the ACL, with Sprains of Different Degrees after Trauma (2021) · cites this paper as [38]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
A New Method to Analyse the Mechanical Behaviour of Skeletal Parts
Brekelmans, W. A. M., Poort, H. W., & Slooff, T. J. J. H. (1972) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677208998949 · Cited by 291
Digital Imaging and Communications in Medicine (DICOM): A Practical Introduction and Survival Guide
Peck, D. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.064592 · Cited by 168
Three-Dimensional Finite Element Simulation of Total Knee Joint in Gait Cycle
Guo, Y., Zhang, X., & Chen, W. (2009) · Acta Mechanica Solida Sinica · doi:10.1016/s0894-9166(09)60283-4 · Cited by 58
Cardiac cone‐beam CT volume reconstruction using ART
Nielsen, T., Manzke, R., Proksa, R., & Graß, M. (2005) · Medical Physics · doi:10.1118/1.1869052 · Cited by 31
Hernández-Vázquez, R. A., Romero-Ángeles, B., Urriolagoitia-Sosa, G., Vázquez-Feijoo, J. A., Vázquez-López, Á. J., & Urriolagoitia-Calderón, G. (2018) · Applied Bionics and Biomechanics · doi:10.1155/2018/4196343 · Cited by 28
Self-citationComputational Intelligence in Medical Informatics
Abraham, A., Liang, Y., & Kelemen, Á. (2008) · Studies in computational intelligence · doi:10.1007/978-3-540-75767-2 · Cited by 18
Beeler, S., Vlachopoulos, L., Jud, L., Sutter, R., Fürnstahl, P., & Fucentese, S. F. (2019) · The Knee · doi:10.1016/j.knee.2019.06.017 · Cited by 16
Chi-Kay, L., Chui, K. H., Lee, K.-B., & Li, W. (2017) · Journal of Orthopaedics Trauma and Rehabilitation · doi:10.1016/j.jotr.2016.11.002 · Cited by 14
Wang, Y., Li, S., Xu, D., Qian, L., Jiang, C., Fu, M., Sun, P., & Ouyang, J. (2019) · The Knee · doi:10.1016/j.knee.2019.01.001 · Cited by 14
Research works printed but not linked: 10
- Mastache-Miranda O. A. Modelado mediante tomografías de volúmenes de estructuras óseas para la simulación numérica bajo la acción de cargas y/o agentes externos, [Master Thesis] 2016 Mexico Instituto Politécnico Nacional
- Giraldo J. C. R. Clavijo C. A. McCollough C. H. Tomografía computarizada por rayos X; Fundamentos y actualidad - X ray cumputed tomography; fundamentals and current status Revista Ingeniería Biomédica 2008 2 4 54 72
- Merchán-Morales S. Estudio densitométrico en maxilar y mandíbula con tomografía computarizada cuantitativa, [Doctoral Thesis] 2013 España Universidad Complutense de Madrid, Facultad de Odontología, Departamento de Medicina y Cirugía Bucofacial
- Mastache-Miranda O. A. Marquet-Rivera R. A. Hernández-Vázquez R. A. Romero-Ángeles B. Urriolagoitia-Calderón G. Importancia de una adecuada reconstrucción tridimensional para su uso en la Medicina y la Biomecánica, procede del 2017 México XVI Congreso Nacional de Ingeniería Electromecánica y de Sistemas
- Martínez-Rodríguez R. Análisis biomecánico para el diseño personalizado de endoprótesis total de rodilla, [Doctoral Thesis] 2012 Mexico Instituto Politécnico Nacional
- Marquet-Rivera R. A. Hernández-Vázquez R. A. Hernández-Cerón A. Egure-Hidalgo M. Romero-Ángeles B. Nuevos alcances de la aplicación del método del elemento finito en la predicción de lesiones y tratamientos, procede del 2017 México XVI Congreso Nacional de Ingeniería Electromecánica y de Sistemas
- Urriolagoitia-Sosa G. Analysis of prior strain history effect on mechanical properties and residual stresses in beams, [ PhD Thesis ] 2005 UK Oxford Brookes University
- Trujillo-Hernández B., 2010, The frequency of risk factors associated with obesity and being overweight in university students from Colima, Mexico, Revista de salud pública, 12, 197
- Cisneros Hidalgo Y. A. González Carbonell R. A. Puente Alvarez A. Camue Corona E. Oropesa Rodríguez Y. Generación de imágenes tridimensionales: integración de tomografía computarizada y método de los elementos finitos Revista Cubana de Investigaciones Biomédicas 2014 33 3 313 321
- Castro-López J. Cordova-Fraga T. Guzmán-Cabrera R. Obtención de la onda dícrota mediante simulación numérica utilizando el modelo de Ogden Computación y Sistemas 2017 21 1 129 136
Cited by
Maya-Anaya, D., Urriolagoitia-Sosa, G., Romero-Ángeles, B., Martinez-Mondragon, M., Germán-Carcaño, J. M., Correa-Corona, M. I., Trejo-Enríquez, A., Sánchez-Cervantes, A., Urriolagoitia-Luna, A., & Urriolagoitia-Calderón, G. (2023) · Applied Sciences · doi:10.3390/app13158903 · Cited by 18
Self-citationSerrato-Pedrosa, J. A., Urriolagoitia-Sosa, G., Romero-Ángeles, B., Urriolagoitia-Calderón, G., Cruz-López, S., Urriolagoitia-Luna, A., Carbajal-López, D. E., Guereca-Ibarra, J. R., & Murillo-Aleman, G. (2024) · Applied Sciences · doi:10.3390/app14041650 · Cited by 14
Self-citationNumerical Analysis of Zirconium and Titanium Implants under the Effect of Critical Masticatory Load
Martinez-Mondragon, M., Urriolagoitia-Sosa, G., Romero-Ángeles, B., Maya-Anaya, D., Martínez-Reyes, J., Gallegos-Funes, F. J., & Urriolagoitia-Calderón, G. (2022) · Materials · doi:10.3390/ma15217843 · Cited by 15
“Biomodeling allows the visualization of bone structures to evaluate anatomy and biological functions by obtaining images with cross-sections of the human body [19].”
BackgroundSelf-citationChen, X., Xue, C., Li, K., Mu, K., Yao, C., Wang, Z., Chen, H., & Zhang, J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1438839 · Cited by 8
Biological dispersion in the time domain using finite element method software
Guedert, R., Andrade, D. L. L. S., Pintarelli, G. B., & Suzuki, D. O. H. (2023) · Scientific Reports · doi:10.1038/s41598-023-49828-1 · Cited by 8
Metadata
- Authors
- Marquet-Rivera, R. A., Urriolagoitia-Sosa, G., Hernández-Vázquez, R. A., Romero-Ángeles, B., Mastache-Miranda, O. A., & Urriolagoitia-Calderón, G.
- Affiliations
- Instituto Politécnico Nacional (MX)
- Polytechnic University of the Valley of Mexico (MX)
- Corresponding author
- Hernández-Vázquez, Rosa Alicia
- ORCID
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2021-01
- Volume
- 2021
- Issue
- 1
- Pages
- 6688164-6688164
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- PMC
- PMC8046528
- OpenAlex
- W3146420953
- Cited by
- 14
- References
- 24
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 4 · 2022: 1 · 2021: 1
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- BioMed Research International (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Consejo Nacional de Ciencia y Tecnología
- Instituto Politécnico Nacional
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- 3D reconstruction, finite element model, 3D printing, biofidelity, soft tissue, hard tissue, meniscus, ligaments, tibial plateau, femur, trabecular bone, cortical bone, tissue mechanical properties, computational resource optimization
- MeSH terms
- Humans, Knee, Ligaments, Magnetic Resonance Imaging, Finite Element Analysis, Imaging, Three-Dimensional, Printing, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.