Contemporary Concepts in Osseointegration of Dental Implants: A Review
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In a society highly conscious of esthetics, prosthetic rehabilitation of lost teeth with tissue‐integrated implants has gained wide acceptance and demand by patients and clinicians. The backbone of these tissue‐integrated implants is the biotechnical process of osseointegration. Although the concept has been introduced and discussed for ages, the deepening knowledge about its cellular and molecular mechanisms has led the researchers to borrow further into the factors influencing the process of osseointegration. This has aided in the hastening and improving the process of osseointegration by exploiting several, even the minutest, details and events taking place in this natural process. Recently, due to the high esthetic expectations of the patients, the implants are being loaded immediately, which demands a high degree of implant stability. Implant stability, especially secondary stability, largely depends on bone formation and integration of implants to the osseous tissues. Various factors that influence the rate and success of osseointegration can either be categorized as those related to implant characteristics like the physical and chemical macro‐ and microdesign of implants or the bone characteristics like the amount and quality of bone and the local and systemic host conditions, or the time or protocol followed for the functional loading of the dental implant. To address the shortcomings in osseointegration due to any of the factors, it is mandatory that continuous and reliable monitoring of the status of osseointegration is done. This review attempts to encompass the mechanisms, factors affecting, and methods to assess osseointegration, followed by a discussion on the recent advances and future perspectives in dental implantology to enhance the process of osseointegration. The review was aimed at igniting the inquisitive minds to usher further the development of technology that enhances osseointegration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The long-term efficacy of currently used dental implants: a review and proposed criteria of success.
Albrektsson, T. O., Zarb, G. A., Worthington, P., & Eriksson, A. R. (1986) · PubMed · Cited by 4,710
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690 · cited 1×
“Furthermore, due to varying threshold limits among patients, implant material, and bone quality and quantity, the test cannot quantify the degree of osseointegration [25].”
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719 · cited 1×
“Sandblasting and acid-etching Sandblasting and acid-etching increases microroughness and surface area Superior bone-to-implant contact (50-60%) at 3 and 6 months as compared to plasmaspraying (30-40%) and electropolished (2025%) implants [54].”
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696 · cited 1×
“Via this protein layer, cell adhesion, migration, and differentiation are initiated, helping an interaction of the cells with the implant surface for several hours or days [10].”
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507 · cited 1×
“Further adjustments are introduced by the extracellular matrix proteins (ECM), cytoskeletal proteins, the cell surface-binding proteins and the binding topography, and the chemical characteristics and ion release [11].”
Contemporary Implant Dentistry
Misch, C. E. (1999) · Implant Dentistry · doi:10.1097/00008505-199901000-00012 · Cited by 1,368
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342 · cited 4×
“(ii) Distant osteogenesis: from the margin of bone to the surface of the implant; de nova formed bone is of woven type [9, 19]”
InfluentialThe Glossary of Prosthodontic Terms
(2005) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2005.03.013 · Cited by 1,323
Understanding Peri‐Implant Endosseous Healing
Davies, J. E. (2003) · Journal of Dental Education · doi:10.1002/j.0022-0337.2003.67.8.tb03681.x · Cited by 1,063 · cited 3×
“(ii) Distant osteogenesis: from the margin of bone to the surface of the implant; de nova formed bone is of woven type [9, 19]”
High surface energy enhances cell response to titanium substrate microstructure
Zhao, G., Schwartz, Z., Wieland, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Boyan, B. D. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30320 · Cited by 922 · cited 1×
“This also accelerates osseointegration by promoting the differentiation and maturation of osteoblasts [69].”
Verborgt, O., Gibson, G. J., & Schaffler, M. B. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.1.60 · Cited by 731
Impact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701 · cited 1×
“Furthermore, the surfaces are being coated with drugs like bisphosphonates to combat any limiting local or systemic host conditions [71].”
Experimental and clinical performance of porous tantalum in orthopedic surgery
Levine, B. R., Sporer, S. M., Poggie, R. A., Valle, C. J. D., & Jacobs, J. J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.041 · Cited by 690 · cited 1×
“Porous tantalum has greater resistance against corrosion and has been used with success as implant material in orthopedic surgeries for improving angiogenesis and wound healing [75].”
A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia
Osman, R. B., & Swain, M. V. (2015) · Materials · doi:10.3390/ma8030932 · Cited by 664 · cited 1×
“Additionally, the zirconia implants have better osseointegration and esthetic properties compared to titanium implants [74].”
Buser, D., Janner, S. F. M., Wittneben, J., Brägger, U., Ramseier, C. A., & Salvi, G. E. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2012.00456.x · Cited by 642 · cited 1×
“Implant survival rate: 95.1%-98.8% [56, 57] Grit-blasted, acid-etched,and Macroroughness by grit-blasting; hydrophobic surface is changed to hydrophilic, increasing the wettability (water contact angle 0 o ) [58] Even the immediately loaded implants showed a higher degree of bone formation and…”
InfluentialDamsky, C. H., & Werb, Z. (1992) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(92)90100-q · Cited by 518
Oral implant surfaces: Part 2--review focusing on clinical knowledge of different surfaces.
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 443
The interface zone of inorganic implantsIn vivo: Titanium implants in bone
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Kasemo, B., Larsson, K., Lundström, I., McQueen, D. H., & Skalak, R. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363944 · Cited by 436 · cited 1×
“However, the layer also in fl uences bio-mineralization by letting the Ca 2+ and PO 43-adsorb on the surface [22, 23].”
Roughness induced dynamic changes of wettability of acid etched titanium implant modifications
Rupp, F., Scheideler, L., Rehbein, D., Axmann, D., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.015 · Cited by 355 · cited 1×
“Grit-blasted, acid-etched, and neutralized implants Macroroughness by grit-blasting; hydrophobic surface is changed to hydrophilic, increasing the wettability (water contact angle 0) [58] Even the immediately loaded implants showed a higher degree of bone formation and satisfactory bone-to-implant contact [59, 60] Suc…”
Fibronectin regulates calvarial osteoblast differentiation
Moursi, A. M., Damsky, C. H., Lull, J., Zimmerman, D., Doty, S. B., Aota, S.-I., & Globus, R. K. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.6.1369 · Cited by 301
Huwais, S., & Meyer, E. (2017) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.4817 · Cited by 294 · cited 1×
“As a result, a compact layer of autogenous bone is created around the implant surface after insertion [85].”
Validity and clinical significance of biomechanical testing of implant/bone interface
Aparicio, C., Lang, N. P., & Rangert, B. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01365.x · Cited by 276 · cited 1×
“The Osstell (electronic technology resonance frequency analysis) and Osstell mentor are advanced versions of this technique (magnetic technology resonance frequency analysis) [50].”
Fibronectin is a survival factor for differentiated osteoblasts
Globus, R. K., Doty, S. B., Lull, J. C., Holmuhamedov, E., Humphries, M. J., & Damsky, C. H. (1998) · Journal of Cell Science · doi:10.1242/jcs.111.10.1385 · Cited by 260
Titanium oral implants: surface characteristics, interface biology and clinical outcome
Palmquist, A., Omar, O. M., Esposito, M., Lausmaa, J., & Thomsen, P. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0118.focus · Cited by 258 · cited 1×
“Moreover, the surface properties of the implant and the novel surface treatments further incite an osteogenic cell response [24].”
Li, D., Ferguson, S. J., Beutler, T., Cochran, D. L., Sittig, C., Hirt, H. P., & Buser, D. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10063 · Cited by 250 · cited 1×
“Superior bone anchorage with higher removal torque values in minipig models [55].”
Nkenke, E., Hahn, M., Weinzierl, K., Radespiel‐Tröger, M., Neukam, F. W., & Engelke, K. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.00937.x · Cited by 238 · cited 1×
“However, due to the invasiveness of the analysis, it is reserved for nonclinical studies or experiments [40, 41].”
Rajpurohit, R., Koch, C. J., Tao, Z., Teixeira, C. M., & Shapiro, I. M. (1996) · Journal of Cellular Physiology · doi:10.1002/(sici)1097-4652(199608)168:2<424::aid-jcp21>3.0.co;2-1 · Cited by 227 · cited 1×
“…dependent on the local oxygen tension and regulatory growth factors, which are further dependent on the position of implant and angiogenesis [17, 18] 2 nd day (i) Local ischemia and necrosis toward the center of the implant site due to the capillary breakdown [19] (ii) Neutrophils become…”
Coelho, P. G., Jimbo, R., Tovar, N., & Bonfante, E. A. (2015) · Dental Materials · doi:10.1016/j.dental.2014.10.007 · Cited by 222 · cited 1×
“Additionally, the instrumentation should be between the inner and outer threads, aiding bone remodeling induced by compression and healing chambers required for the migration of osteogenic cells [51 – 53].”
Tabassum, A., Meijer, G. J., Wolke, J. G. C., & Jansen, J. A. (2010) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01823.x · Cited by 184 · cited 1×
“[80] and in a systematic review by Stocchero et al.”
Chen, J., Cai, M., Yang, J., Aldhohrah, T., & Wang, Y. (2019) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.05.013 · Cited by 166 · cited 1×
“[38] comparing the efficacy of immediate versus conventional implant loading, the authors concluded that immediate loading could achieve comparable implant survival rates compared to early loading, but not when compared to conventional loading.”
Nevins, M., Kim, D. M., Jun, S.-H., Guze, K. A., Schüpbach, P., & Nevins, M. L. (2010) · PubMed · Cited by 162
Biologic determinants of bone formation for osseointegration: Clues for future clinical improvements
Cooper, L. F. (1998) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70009-5 · Cited by 157 · cited 1×
“1 day (i) Secretion of growth factors by water molecules and platelet absorption at the site of implant placed [15] (ii) Nondifferentiated osteoblasts stick to the implant surface through the aid of fibronectin [16] (iii) Migration of pluripotent mesenchymal cells along the implant surface, with their function depende…”
Fischer, K., & Stenberg, T. (2011) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2011.00389.x · Cited by 151 · cited 1×
“Implant survival rate: 95.1%-98.8% [56, 57] Grit-blasted, acid-etched,and Macroroughness by grit-blasting; hydrophobic surface is changed to hydrophilic, increasing the wettability (water contact angle 0 o ) [58] Even the immediately loaded implants showed a higher degree of bone formation and…”
InfluentialEarly detachment of titanium particles from various different surfaces of endosseous dental implants
Franchi, M., Bacchelli, B., Martini, D., Pasquale, V. D., Orsini, E., Ottani, V., Fini, M., Giavaresi, G., Giardino, R., & Ruggeri, A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.017 · Cited by 142 · cited 1×
“deposition CaP particles (20-100 nm) deposited on a double acidetched surface by a sol-gel process exert a high adhesive force on the implant surface; bacterial adhesion is reduced [62, 63] Disruption force required at the bone-implant interface is high;”
Kitsugi, T., Nakamura, T., Oka, M., Senaha, Y., Goto, T., & Shibuya, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199602)30:2<261::aid-jbm17>3.0.co;2-p · Cited by 141 · cited 1×
“…on a double acid-etched surface by a sol-gel process exert a high adhesive force on the implant surface; bacterial adhesion is reduced [62, 63] Disruption force required at the bone-implant interface is high; high osteoconduction [64] One year survival rate 94.9%- 99.4% [65, 66] Generates…”
InfluentialMendes, V. C., Moineddin, R., & Davies, J. E. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32126 · Cited by 137 · cited 1×
“high osteoconduction [64] One year survival rate 94.”
Inchingolo, A. D., Inchingolo, A. M., Bordea, I. R., Xhajanka, E., Romeo, D. M., Romeo, M., Zappone, C. M. F., Malcangi, G., Scarano, A., Lorusso, F., et al. (2021) · Materials · doi:10.3390/ma14051147 · Cited by 127 · cited 1×
“All of the parameters measured were higher for osseodensification compared to the conventional drilling, which suggests that osseodensification is a superior technique to achieve better osseointegration especially in areas of low bone density [86].”
Surface modifications of a titanium implant by a picosecond Nd:YAG laser operating at 1064 and 532nm
Trtica, M. S., Gaković, B. M., Batani, D., Desai, T., Panjan, P., & Radak, B. B. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.05.024 · Cited by 115
Abhay, S. S., Ganapathy, D. M., Veeraiyan, D. N., Ariga, P., Heboyan, A. G., Amornvit, P., Rokaya, D., & Srimaneepong, V. (2021) · Polymers · doi:10.3390/polym13213761 · Cited by 95 · cited 1×
“Moreover, PEEK also possesses superior color stability and higher abrasion resistance than zirconia [78].”
Self-citationUse of bovine osteogenic protein to promote rapid osseointegration of endosseous dental implants.
Rutherford, R. B., Tk, S., Rueger, D. C., & Td, T. (1992) · PubMed · Cited by 93
Photofunctionalization increases the bioactivity and osteoconductivity of the titanium alloy Ti6Al4V
Minamikawa, H., Ikeda, T., Att, W., Hagiwara, Y., Hirota, M., Tabuchi, M., Aita, H., Park, W., & Ogawa, T. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35030 · Cited by 90 · cited 1×
“Also, it reduces surface hydrocarbon, improves wettability, increases protein adsorption and cellular attachment to titanium surfaces, and restores bioactivity that gets diminished due to age-related degradations [70].”
Neugebauer, J., Traini, T., Thams, U., Piattelli, A., & Zöller, J. E. (2006) · Journal of Periodontology · doi:10.1902/jop.2006.040360 · Cited by 85 · cited 1×
“Grit-blasted, acid-etched, and neutralized implants Macroroughness by grit-blasting; hydrophobic surface is changed to hydrophilic, increasing the wettability (water contact angle 0) [58] Even the immediately loaded implants showed a higher degree of bone formation and satisfactory bone-to-implant contact [59, 60] Suc…”
Novaes, A. B., Papalexiou, V., Grisi, M. F. M., Souza, S. S. L. S., Taba, M., & Kajiwara, J. K. (2004) · Clinical Oral Implants Research · doi:10.1046/j.1600-0501.2003.00968.x · Cited by 83 · cited 1×
“Grit-blasted, acid-etched, and neutralized implants Macroroughness by grit-blasting; hydrophobic surface is changed to hydrophilic, increasing the wettability (water contact angle 0) [58] Even the immediately loaded implants showed a higher degree of bone formation and satisfactory bone-to-implant contact [59, 60] Suc…”
Marin, C., Granato, R., Suzuki, M., Gil, J. N., Janal, M. N., & Coelho, P. G. (2010) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01853.x · Cited by 83
Degidi, M., Piattelli, A., Gehrke, P., & Carinci, F. (2006) · PubMed · Cited by 75
Stocchero, M., Toia, M., Cecchinato, D., Becktor, J. P., Coelho, P. G., & Jimbo, R. (2016) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.5340 · Cited by 72 · cited 1×
“The e ff ectiveness of the undersized drill to achieve higher primary stability has been shown in an experimental study by Tobassum et al. [80] and in a systematic review by Stocchero et al. [81].”
Irinakis, T., & Wiebe, C. (2009) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-09-00020.1 · Cited by 72 · cited 1×
“Similarly, insertion torque values can be used to assess the quality of bone in various parts of the jaw during implant placement, but they cannot evaluate the secondary stability provided by the new peri-implant bone formation and remodeling [47].”
Östman, P., Wennerberg, A., & Albrektsson, T. O. (2008) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2008.00128.x · Cited by 67
Kuroshima, S., Nakano, T., Ishimoto, T., Sasaki, M., Inoue, M., Yasutake, M., & Sawase, T. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.021 · Cited by 61 · cited 1×
“Studies have shown that implant design with grooves oriented +60 (downwards) to the long axis of the implant attracts higher densities of osteocytes in the peri-implant area [30].”
Farronato, D., Mangano, F. G., Briguglio, F., Iorio‐Siciliano, V., Riccitiello, F., & Guarnieri, R. (2014) · The International Journal of Periodontics & Restorative Dentistry · doi:10.11607/prd.1747 · Cited by 59 · cited 1×
“long-term comparative results not yet available [68] 7 BioMed Research International”
Östman, P., Wennerberg, A., Ekestubbe, A., & Albrektsson, T. O. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2011.00437.x · Cited by 50
Biocompatibility and the Efficacy of Medical Implants
Shard, A. G., & Tomlins, P. E. (2006) · Regenerative Medicine · doi:10.2217/17460751.1.6.789 · Cited by 49 · cited 1×
“First, the implant is placed in the bone, and water forms a layer in the surrounding within nanoseconds, facilitating the absorption of protein and other essential molecules [8].”
Piglionico, S. S., Bousquet, J., Fatima, N., Renaud, M., Collart-Dutilleul, P.-Y., & Bousquet, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113657 · Cited by 48 · cited 1×
“concluded that porous tantalum has greater osseointegration capacity than the currently available smooth or roughened titanium implants [76].”
Metallic Biomaterials for Medical and Dental Prosthetic Applications
Rokaya, D., Bohara, S., Srimaneepong, V., Kongkiatkamon, S., Khurshid, Z., Heboyan, A. G., Zafar, M. S., & Sapkota, J. (2022) · Springer eBooks · doi:10.1007/978-981-16-7152-4_18 · Cited by 43
Self-citationÖstman, P., Hupalo, M., del Castillo, R., Emery, R. W., Cocchetto, R., Vincenzi, G., Wagenberg, B. D., Vanassche, B. J. E., Valentin, A., Clausen, G., et al. (2009) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2009.00166.x · Cited by 34 · cited 1×
“…is reduced [62, 63] Disruption force required at the bone-implant interface is high; high osteoconduction [64] One year survival rate 94.9%- 99.4% [65, 66] Generates a pattern of nanoscale microchannels that act as a biological seal by eliciting the connective tissue and bone attachment,…”
InfluentialShah, F. A., Stenlund, P., Martinelli, A., Thomsen, P., & Palmquist, A. (2016) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-016-5779-1 · Cited by 33 · cited 1×
“However, due to the invasiveness of the analysis, it is reserved for nonclinical studies or experiments [40, 41].”
Tsolaki, I. N., Tonsekar, P., Najafi, B., Drew, H. J., Sullivan, A. J., & Petrov, S. D. (2016) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-15-00176 · Cited by 33 · cited 1×
“The technique is believed to reduce the microdeformations and maximize the preservation of remaining bone [82].”
Biological Responses to New Advanced Surface Modifications of Endosseous Medical Implants
Singhatanadgit, W. (2009) · Bone and Tissue Regeneration Insights · doi:10.4137/btri.s3150 · Cited by 32 · cited 1×
“…of implant, the macro-and microscopic topography of implant surface, design of the implant, bone morphology and quality at the implant site, the surgical technique employed, stability of local and systemic health during the healing phase, and the loading conditions and protocol followed [25 – 28].”
Metadata
- Authors
- Pandey, C., Rokaya, D., & Bhattarai, B. P.
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2022-01
- Volume
- 2022
- Issue
- 1
- Pages
- 6170452-6170452
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- OpenAlex
- W4282921236
- Cited by
- 197
- References
- 58
- FWCI
- 29.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.