Optimizing Radiolabeled Engineered Anti-p185HER2 Antibody Fragments for In vivo Imaging
Open accessThe DOI matches its Crossref record.
Abstract
We have recently described the in vivo properties of an iodinated anti-p185HER2 engineered antibody fragment [minibody (scFv-CH3)2; 80 kDa], made from the internalizing 10H8 monoclonal antibody. Although the 10H8 minibody showed excellent binding to the target in vitro, only modest tumor uptake [5.6 ± 1.7% injected dose per gram (ID/g) of tissue] was achieved in nude mice bearing MCF7/HER2 breast cancer tumors. Here, in an attempt to improve targeting, the 10H8 minibody was conjugated to 1,4,7,10-tetraazacyclododecane-N, N′, N′′, N′′′-tetraacetic acid (DOTA), radiometal labeled, and evaluated in vivo. The tumor uptake of 111In-DOTA 10H8 minibody was 5.7 ± 0.1% ID/g, similar to the radioiodinated 10H8 minibody. However, in addition to the expected liver clearance, the kidneys had unexpectedly high activity (34.0 ± 4.0% ID/g). A minibody derived from a second anti-p185HER2 antibody (trastuzumab; hu4D5v8) was also made. Tumor uptakes, evaluated by quantitative microPET using 64Cu-DOTA hu4D5v8 minibody, were 4.2 ± 0.5% ID/g. Furthermore, in non-tumor-bearing mice, 111In-DOTA hu4D5v8 minibody exhibited similar elevated uptake in the kidneys (28.4 ± 6.5% ID/g). Immunohistochemical staining of kidneys from non-tumor-bearing mice showed strong specific staining of the proximal tubules, and Western blot analysis of kidney lysate confirmed the presence of cross-reactive antigen. To further improve tumor uptake and normal tissue distribution, a larger hu4D5v8 fragment [(scFv-CH2-CH3)2; 105 kDa] was made, engineered to exhibit rapid clearance kinetics. This fragment, when evaluated by microPET, exhibited improved tumor targeting (12.2 ± 2.4% ID/g) and reduced kidney uptake (13.1 ± 1.5% ID/g). Thus, by manipulating the size and format of anti-p185HER2 antibody fragments, the kidney activity was reduced and high or low expression of p185HER2 in xenografts could be distinguished by microPET imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engineered antibody fragments and the rise of single domains
Holliger, P., & Hudson, P. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1142 · Cited by 1,931
Arming antibodies: prospects and challenges for immunoconjugates
Wu, A. M., & Senter, P. D. (2005) · Nature Biotechnology · doi:10.1038/nbt1141 · Cited by 1,052
Self-citationTumor Imaging Using a Picomolar Affinity HER2 Binding Affibody Molecule
Orlova, A., Magnusson, M., Eriksson, T. L. J., Nilsson, M., Larsson, B., Höidén-Guthenberg, I., Widström, C., Carlsson, J., Tolmachev, V., Ståhl, S., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-3521 · Cited by 568
Nanoparticles for combination drug therapy
Ma, L., Kohli, M., & Smith, A. (2013) · ACS Nano · doi:10.1021/nn405674m · Cited by 367
Inorganic nanoparticle-based contrast agents for molecular imaging
Cho, E. C., Glaus, C., Chen, J., Welch, M. J., & Xia, Y. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.09.004 · Cited by 247
Metadata
- Authors
- Olafsen, T., Kenanova, V. E., Sundaresan, G., Anderson, A.-L., Crow, D., Yazaki, P. J., Li, L., Press, M. F., Gambhir, S. S., Williams, L. E., Wong, J. Y. C., Raubitschek, A. A., Shively, J. E., & Wu, A. M.
- Venue
- Cancer Research
- Published
- 2005-07-01
- Volume
- 65
- Issue
- 13
- Pages
- 5907-5916
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2162375550
- Cited by
- 155
- References
- 0
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimizing Radiolabeled Engineered Anti-p185HER2 Antibody Fragments for In vivo Imaging. https://app.cochat.ai/papers/10.1158/0008-5472.can-04-4472
- The paper
- Olafsen, T., Kenanova, V. E., Sundaresan, G., Anderson, A.-L., Crow, D., Yazaki, P. J., Li, L., Press, M. F., Gambhir, S. S., Williams, L. E., Wong, J. Y. C., Raubitschek, A. A., Shively, J. E., & Wu, A. M. (2005). Optimizing Radiolabeled Engineered Anti-p185HER2 Antibody Fragments for In vivo Imaging. Cancer Research. https://doi.org/10.1158/0008-5472.can-04-4472
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.