Optimal Dosing for Targeted Therapies in Oncology: Drug Development Cases Leading by Example
Published version of a preprint
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
One of the key objectives of oncology first-in-human trials has often been to establish the maximum tolerated dose (MTD). However, targeted therapies might not exhibit dose-limiting toxicities (DLT) at doses significantly higher than sufficiently active doses, and there is frequently a limited ability to objectively quantify adverse events. Thus, while MTD-based determination of recommended phase II dose may have yielded appropriate dosing for some cytotoxics, targeted therapeutics (including monoclonal antibodies and/or immunotherapies) sometimes need alternative or complementary strategies to help identify dose ranges for a randomized dose-ranging study. One complementary strategy is to define a biologically efficacious dose (BED) using an “effect marker.” An effect marker could be a target engagement, pharmacodynamic, or disease progression marker (change in tumor size for solid tumors or bone marrow blast count for some hematologic tumors). Although the concept of BED has been discussed extensively, we review specific examples in which the approach influenced oncology clinical development. Data extracted from the literature and the examples support improving dose selection strategies to benefit patients, providers, and the biopharmaceutical industry. Although the examples illustrate key contributions of effect markers in dose selection, no one-size-fits-all approach to dosing can be justified. Higher-than-optimal dosing can increase toxicity in later trials (and in clinical use), which can have a negative impact on efficacy (via lower adherence or direct sequelae of toxicities). Proper dose selection in oncology should follow a multifactorial decision process leading to a randomized, dose-ranging study instead of a single phase II dose. Clin Cancer Res; 22(6); 1318–24. ©2015 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“An alternative strategy focuses on identifying a biologically effective dose based on an array of efficacy markers, such as target engagement, pharmacodynamic markers, and, for bispecific therapeutics, trimer formation. 7 , 11 , 12”
From Semimechanistic Physiologically‐Based Pharmacokinetic/Pharmacodynamic Model Informing Epcoritamab Dose Selection for Patients With B‐Cell Lymphomas (2022) · cites this paper as [7]
In the citing paper
“However, for targeted therapeutics (e.g., mAbs, bsAbs), dose‐limiting toxicities may not occur until doses are considerably higher than effective doses, thereby complicating the decision criteria for stopping dose escalation. 7”
From Semimechanistic Physiologically‐Based Pharmacokinetic/Pharmacodynamic Model Informing Epcoritamab Dose Selection for Patients With B‐Cell Lymphomas (2022) · cites this paper as [7]
In the citing paper
“Therefore, employing MTD‐based strategies to identify the RP2D can sometimes lead to selection of a dose that is much higher than a sufficiently effective dose. 7”
From Semimechanistic Physiologically‐Based Pharmacokinetic/Pharmacodynamic Model Informing Epcoritamab Dose Selection for Patients With B‐Cell Lymphomas (2022) · cites this paper as [7]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anaplastic Lymphoma Kinase Inhibition in Non–Small-Cell Lung Cancer
Kwak, E. L., Bang, Y.-J., Camidge, D. R., Shaw, A. T., Solomon, B., Maki, R. G., Ou, S.-H. I., Dezube, B. J., Jänne, P. A., Costa, D. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1006448 · Cited by 4,446 · cited 2×
“An overall response rate of 57% and an estimated probability of 6month PFS of 72% were reported (33).”
BackgroundCombining immunotherapy and targeted therapies in cancer treatment
Vanneman, M., & Dranoff, G. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3237 · Cited by 1,586 · cited 1×
“, crizotinib) and, possibly, combination therapies (39).”
Cabozantinib in Progressive Medullary Thyroid Cancer
Elisei, R., Schlumberger, M. J., Müller, S. P., Schöffski, P., Brose, M. S., Shah, M. H., Licitra, L., Jarzab, B., Medvedev, V., Kreissl, M. C., et al. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2012.48.4659 · Cited by 1,217 · cited 1×
“Although lower exposure did not reduce progression-free survival (PFS), higher exposure was associated with earlier dose reduction; at the 140-mg dose 69% of patients had dose holds and 79% of subjects reduced their doses (7, 8).”
BackgroundDose Escalation Methods in Phase I Cancer Clinical Trials
Le Tourneau, C., Lee, J. J., & Siu, L. L. (2009) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djp079 · Cited by 867
Issa, J.-P. J., Garcia-Manero, G., Giles, F. J., Mannari, R., Thomas, D., Faderl, S., Bayar, E., Lyons, J., Rosenfeld, C. S., Cortes, J., et al. (2004) · Blood · doi:10.1182/blood-2003-03-0687 · Cited by 809 · cited 3×
“This time, the focus of clinical trials for acute myelogenous leukemia (AML) was on identifying a dose based on pharmacodynamics rather than an MTD (29).”
BackgroundInfluentialPatnaik, A., Kang, S. P., Rasco, D., Papadopoulos, K. P., Elassaiss-Schaap, J., Beeram, M., Drengler, R., Chen, C., Smith, L., Espino, G., et al. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-2607 · Cited by 807
Self-citationBaselga, J., Pfister, D., Cooper, M. R., Cohen, R., Burtness, B., Bos, M., D’Andrea, G., Seidman, A., Norton, L., Gunnett, K., et al. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.4.904 · Cited by 741 · cited 1×
“For some targeted agents, mechanism-based AEs, such as skin rash can also be used (24).”
BackgroundBrown, J. R., Byrd, J. C., Coutre, S. E., Benson, D. M., Flinn, I. W., Wagner-Johnston, N. D., Spurgeon, S. E., Kahl, B. S., Bello, C., Webb, H. K., et al. (2014) · Blood · doi:10.1182/blood-2013-11-535047 · Cited by 590 · cited 2×
“Furthermore, tumor response, assessed by changes in tumor size, approached plateau in CLL and NHL patients at exposures obtained with a dose of 150mg twice a day (5, 27, 28), adding strong evidence to justify dose selection.”
BackgroundKurzrock, R., Sherman, S. I., Ball, D. W., Forastiere, A. A., Cohen, R. B., Mehra, R., Pfister, D. G., Cohen, E. E. W., Janisch, L., Nauling, F., et al. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2010.32.4145 · Cited by 550 · cited 6×
“org Clin Cancer Res; 22(6) March 15, 2016 1321”
BackgroundInfluentialLoRusso, P. M., Rudin, C. M., Reddy, J. C., Tibes, R., Weiss, G. J., Borad, M. J., Hann, C. L., Brahmer, J. R., Chang, I., Darbonne, W. C., et al. (2011) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-10-2745 · Cited by 544 · cited 1×
“In phase I, three dose levelswere administered (31): 150, 270, and540mg/d.”
Method
Research works printed but not linked: 3
- Dose selection for small molecule oncology drugs: present state and future considerations. N Mehrotra, Proceedings of the FDA-AACR Meeting (Dose-finding of small molecule oncology drugs). the FDA-AACR Meeting (Dose-finding of small molecule oncology drugs)2015 May 18-19abstract
- Model informed drug development: is there a need to repaint the canvas?. V Sinha, Proceedings of the 23rd Annual Meeting of the Population Approach Group in Europe. the 23rd Annual Meeting of the Population Approach Group in Europe2014 Jun 10-13abstract
- Proceedings of the FDA-AACR Meeting (Dose-finding of small molecule oncology drugs). the FDA-AACR Meeting (Dose-finding of small molecule oncology drugs)American Association for Cancer Research2015 May 18-19
Cited by
Items 101–159 of 159
Noronha, V., Shah, M. J., Kapoor, A., Menon, N. S., Patil, V., Rajendra, A., Dhar, A., Goud, S., More, S. B., Yadav, A., et al. (2026) · JCO Global Oncology · doi:10.1200/go-25-00505 · Cited by 5
Michelet, R., Petersson, K., Huisman, M. C., van Oordt, C. W. M. D. H., Miedema, I. H. C., Thiele, A., Montaseri, G., Pérez‐Pitarch, A., & Busse, D. (2024) · CPT Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.13285 · Cited by 5
Li, M., Guo, Z., & Qiu, Y. (2025) · Statistics in Medicine · doi:10.1002/sim.70098 · Cited by 5
Okubo, T., & Ono, S. (2017) · Clinical and Translational Science · doi:10.1111/cts.12462 · Cited by 5
New strategies in esophageal carcinoma: promises and problems
Xiong, Z., He, J., & Chen, X. L. (2016) · Journal of Thoracic Disease · doi:10.21037/jtd.2016.11.22 · Cited by 5
Liu, W. A., Yu, L. J., Morcos, P. N., Mercier, F., & Brennan, B. J. (2020) · Cancer Chemotherapy and Pharmacology · doi:10.1007/s00280-020-04076-2 · Cited by 5
Qiu, Y., & Li, M. (2025) · Statistical Methods in Medical Research · doi:10.1177/09622802251374290 · Cited by 4
Korula, A., Kulkarni, U., Arunachalam, A. K., Datari, P. V. R., Pai, A. A., Mathew, S., Aboobacker, F. N., Selvarajan, S., Lionel, S. A., Lakshmi, K., et al. (2025) · Blood Immunology & Cellular Therapy · doi:10.1016/j.bict.2025.100011 · Cited by 4
Jessen, B. A., Cornwell, P. D., Redmond, S., Visalli, T., Lemper, M., Bunch, R. T., & Hart, T. K. (2023) · Cancer Chemotherapy and Pharmacology · doi:10.1007/s00280-023-04570-3 · Cited by 4
“Molecularly targeted agents (MTA) are based on different mechanisms of action, and these targeted therapies may sometimes require alternative approaches to identify appropriate dose ranges [6].”
BackgroundImmuno-PET to Optimize the Dose of Monoclonal Antibodies for Cancer Therapy: How Much Is Enough?
Reilly, R. M. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.225854 · Cited by 4
“a dose that is mechanistically optimal have been proposed as a more rational approach for dosing mAbs for cancer treatment (5).”
Background2D (2 Dimensional) TEQR design for Determining the optimal Dose for safety and efficacy
Ananthakrishnan, R., Green, S., Li, D., & LaValley, M. P. (2019) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2019.100461 · Cited by 4
Fan, S. K., Lee, B. L., & Lü, Y. (2020) · Statistics in Biosciences · doi:10.1007/s12561-020-09272-5 · Cited by 4
Botrugno, O. A., Bianchi, E., Bruno, J. M., Gallo, G. F. M., Felici, C., Sommella, E., Stefano, P. D., Giansanti, V., Rossella, V., Merciai, F., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.12.28.630600 · Cited by 5
Porter, S., Eaton, A. A., & Murray, T. A. (2025) · Statistical Methods in Medical Research · doi:10.1177/09622802251327691 · Cited by 3
Mittal, A., Green, A., Fitzgerald, X., Spain, L., Phillips, C., Wirth, A., Haghighi, N., Plumridge, N. M., Li, M. P., & Sia, J. (2025) · Neuro-Oncology Advances · doi:10.1093/noajnl/vdaf130 · Cited by 3
“19 25 It is therefore complex to speculate on the pharmacokinetics of ICB within BrM tumors and their differential effects on any interaction with SRS. 28 Noting that the brain has a distinctly regulated immunosurveillance program that was long assumed silent, 21 recent studies on BrM treated with…”
Phillips, A., & Mondal, S. (2023) · Pharmaceutical Statistics · doi:10.1002/pst.2291 · Cited by 3
“Further, some of the therapies demonstrate minimal toxicity even in high doses, making the MTD unlikely to be reached.(3,4) As a result, designs aimed at finding the MTD are inappropriate for such therapies generally and, when used in that context, are likely to lead to finding inappropriate doses for future research.”
BackgroundEvolving or immutable - phase I solid tumor trials in the era of precision oncology
Stockton, S. S., Ayers, G. D., Lee, C. S., Laferriere, H. E., Das, S., & Berlin, J. D. (2024) · Investigational New Drugs · doi:10.1007/s10637-024-01445-z · Cited by 3
“Novel therapeutics such as TT and IO possess different intrinsic relationships between dose, toxic - ity and efficacy; the RP2D of an agent may be the biologi - cally effective dose (BED) rather than MTD [ 6].”
BackgroundPorter, S., Murray, T. A., & Eaton, A. A. (2024) · Statistics in Medicine · doi:10.1002/sim.10256 · Cited by 4
Sofi, H. S., Lora, A. J., Donow, H. M., Dickinson, S. E., Wondrak, G. T., Chow, H. ‐. S., Curiel‐Lewandrowski, C. N., & Mansour, H. M. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16111409 · Cited by 3
“However, this approach has limitations regarding targeted therapies, where an alternative approach called the biologically efficacious dose (BED), which balances safety and efficacy, is used [61].”
Integrating Biomarkers in Early-Phase Trials
Parchment, R. E., Ferry‐Galow, K. V., & Doroshow, J. H. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812512-0.00008-7 · Cited by 4
Iida, H., Fujikawa, R., Kozaki, R., Harada, R., Hosokawa, Y., Ogawara, K., & Ohno, T. (2020) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.119.264499 · Cited by 3
“Determination of recommended doses in recent early-stage oncologic clinical development of molecu-larlytargetedagentshasbeenshiftingfromtraditionalmaximumtolerateddose(MTD)-basedstrategiestofindingbiologically effectivedose-basedstrategiesusingeffectmarkers(Sachs etal.,2016).”
BackgroundKitabayashi, R., Takeda, K., Sato, H., & Hirakawa, A. (2025) · Pharmaceutical Statistics · doi:10.1002/pst.70045 · Cited by 2
Optimizing Dosing Strategies in Cell Therapy With Machine Learning and Exposure‐Response Integration
Wang, S., Zhao, Y., Li, J., Liu, R., & Mugundu, G. M. (2025) · Pharmaceutical Statistics · doi:10.1002/pst.70048 · Cited by 2
Trivedi, C. R., John, J., Karumathil, S., Selvarajan, S., Lionel, S. A., Hephzibah, J., Sunny, S. S., Chandramohan, A., Kulkarni, U. P., Lakshmi, K. M., et al. (2026) · JCO Global Oncology · doi:10.1200/go-25-00424 · Cited by 2
Zhou, X., Mould, D. R., Gore, L., Bai, X., & Gupta, N. (2025) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.3629 · Cited by 2
Complexity in Clinical Trials: Blind Spots, Misleading Criteria, Winners and Losers
Yuan, G., Wang, L., Li, J., Feng, H., Ji, J., Gu, W., & Shan, B. (2019) · Clinical Cancer Drugs · doi:10.2174/2212697x06666191021125423 · Cited by 2
Dose Finding in Oncology: What is Impeding Coming of Age?
Mayawala, K., & de Alwis, D. P. (2022) · Pharmaceutical Research · doi:10.1007/s11095-022-03263-5 · Cited by 2
Self-citationBalancing speed, science and regulatory requirements in oncology drug development
Snyder, A., de Alwis, D. P., Goonewardene, A., & Hegde, P. S. (2022) · Nature Medicine · doi:10.1038/s41591-022-01975-0 · Cited by 2
The Role of Early-Phase Design—Letter
Ratain, M. J. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-0350 · Cited by 2
“In this context, I would encourage biostatisticians and others interested in the design of early clinical trials to focus their efforts on a different paradigm, one in which the optimal dose can only be determined by randomized dose-ranging phase II and III trials (4, 5).”
BackgroundCharlab, R., Leong, R., Shord, S. S., & Reaman, G. H. (2024) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a041656 · Cited by 2
Chi, X., Lin, R., & Yuan, Y. (2025) · Biometrics · doi:10.1093/biomtc/ujaf077 · Cited by 1
Modelling and optimizing combination therapeutic strategies for KRAS- and EGFR-mutant lung cancer
Wu, L.-H., Yu, R., Yao, M., Rahaman, M. M., & Fang, Z. (2025) · Journal of Bioinformatics and Computational Biology · doi:10.1142/s0219720025500179 · Cited by 1
Optimizing chemoradiotherapy for malignant gliomas: A validated mathematical approach
Perales-Patón, M., Italia, M., Castelló-Pons, M., Gómez-Soria, I., Belmonte-Beitia, J., Gómez, P. S., & Pérez‐García, V. M. (2026) · Applied Mathematical Modelling · doi:10.1016/j.apm.2026.117093 · Cited by 1
“Emerging evidence suggests that aggressive treatment regimens, like the Stupp protocol, may not be universally effective across all cancer types or patient populations [8,9].”
Park, S., Lee, S. M., Pak, K. C., Byun, M.-S., Choi, D., & Lim, H. (2025) · Drug Design Development and Therapy · doi:10.2147/dddt.s564085 · Cited by 1
The Locally Active‐Controlled Optimal Design: Applications in Oncology Clinical Studies
Zhang, X., & Shen, G. (2025) · Biometrical Journal · doi:10.1002/bimj.70097 · Cited by 1
Dose Optimization Design for Randomized Phase II Trials With Toxicity and Efficacy Endpoints
Tabata, R., Ohigashi, T., & Sozu, T. (2026) · Pharmaceutical Statistics · doi:10.1002/pst.70112 · Cited by 1
Overview of model-assisted design for phase I dose-finding trials in oncology
Hashizume, K., Takeda, K., Sato, H., Hirakawa, A., & Sozu, T. (2022) · Japanese Journal of Biometrics · doi:10.5691/jjb.43.3 · Cited by 1
How to Design Phase I Trials in Oncology
Carter, L., O’Brien, C., Dean, E. J., & Cook, N. (2018) · Springer eBooks · doi:10.1007/978-3-319-71324-3_10
Paradigms in Cancer Drug Development: A Universe with Many Galaxies
Hierro, C., & Rodon, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-47682-3_2
Caquelin, L., Badra, P., Poulain, L., Laviolle, B., Ursino, M., & Locher, C. (2024) · Research Synthesis Methods · doi:10.1002/jrsm.1747
“Indeed, some studies showed that the approved dose for targeted therapy, including PKIs, are generally below the MTD estimates in phase I. 23,24 There is also sometimes the need for a post-marketing dose reduction, with the suggestion that ‘ a lower dose might be effective with improved…”
Marzano, L., Dan, A., Darwich, A. S., Petris, L. D., Tendler, S., Lewensohn, R., Raghothama, J., & Meijer, S. (2024) · medRxiv · doi:10.1101/2024.12.04.24318490
Towards Efficient Time‐to‐Event Dose‐Escalation Guidance of Multi‐Cycle Cancer Therapies
Widmer, L. A., Weber, S., Xu, Y., & Weber, H. (2025) · Statistics in Medicine · doi:10.1002/sim.70229
“A meta-analysis conducted in 2015 revealed that the suggested dose from drug labels of 62% FDA-approved compounds were lower than their MTD [6].”
Nonami, A., Matsuda, K., Funakoshi, K., Kato, R., Takahashi, H. W., & Edahiro, Y. (2025) · Clinical and Translational Science · doi:10.1111/cts.70367
Luo, X., Du, X., Chen, Q., Wang, C., Li, L., He, X., Gong, Y., Chen, J., Zhong, X., Liu, Y., et al. (2026) · iScience · doi:10.1016/j.isci.2025.114613
“37,38 Additionally, since targeted therapies are administered over prolonged periods, excessively high doses may significantly impair the patients’ adherence and quality of life.”
Marzano, L., Dan, A., Darwich, A. S., Petris, L. D., Tendler, S., Lewensohn, R., Raghothama, J., & Meijer, S. (2026) · JMIR Cancer · doi:10.2196/84042
“This could suggest the need to identify key covariates and clinically relevant subgroups that might inform a more tailored dosing, or in some cases, guide decisions against treatment altogether, in order to improve survival while avoiding AEs in patients unlikely to benefit from therapy [11,12,45].”
Nouveaux biomarqueurs en imagerie du myélome multiple
Bailly, C. (2019) · theses.fr (ABES) · doi:10.70675/4fa20aafz6f24z4930zb9e0zfd5873d01dba
Enabling Practical Response-Adaptive Randomisation Designs New Insights, Theory and Applications
Pin, L. (2026) · Apollo (University of Cambridge) · doi:10.17863/cam.129095 · Cited by 1
Caquelin, L. (2023) · theses.fr (ABES) · doi:10.70675/13ebb540z3938z4806z9ac3z3fac95f76f1e
Extraction et prédiction des réponses aux chimiothérapies à partir des données hospitalières
Rogier, A. (2024) · theses.fr (ABES) · doi:10.70675/34ed30a2z6f57z4a39z966az6727b12bb89d
Chakraborty, S., Dubey, A., Kumar, A., & Chan, I. (2026) · Statistics in Biopharmaceutical Research · doi:10.1080/19466315.2026.2668381
Qiu, Y., & Li, M. (2026) · Statistics in Biopharmaceutical Research · doi:10.1080/19466315.2026.2703535
Zheng, X., Yu, Z., Kaplan, M., Gkasiamis, A., Sudhindra, A., Zhu, L., Lamba, M., & Wu, F. (2026) · British Journal of Clinical Pharmacology · doi:10.1002/bcp.70728
Yamaguchi, D. T., Nogami, W., Sonoda, Y., Morihara, H., & Katsube, T. (2026) · CPT Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.70332
Jin, X., Ma, J., Hou, H., Zhang, X., Zhang, X., Zhang, S., Wang, H., Zhao, X., & Zhang, G. (2026) · Biochemical Pharmacology · doi:10.1016/j.bcp.2026.118460
Liu, L., Lin, R., & Wages, N. A. (2026) · Pharmaceutical Statistics · doi:10.1002/pst.70120
Deng, A., Zhu, X., Sheng, H., Li, Y., Chen, T., & Huang, S. (2026) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.70522
Swain, S. K., Panda, S. S., Moharana, L., Samantaray, L., Patnaik, A., Mohanty, S. S., Inimerla, B., Dubey, A., Singhal, R., & Biswas, G. (2026) · Research Square · doi:10.21203/rs.3.rs-11034854/v1
Metadata
- Authors
- Sachs, J. R., Mayawala, K., Gadamsetty, S., Kang, S. P., & de Alwis, D. P.
- Affiliations
- Merck & Co., Inc., Rahway, NJ, USA (United States) (US)
- 2Department of PPDM-Quantitative Pharmacology and Pharmacometrics, Merck & Co., Inc., Rahway, New Jersey.
- Venue
- Clinical Cancer Research
- Published
- 2016-03-14
- Volume
- 22
- Issue
- 6
- Pages
- 1318-1324
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2173235643
- Semantic Scholar
- 3bf9f8fe909362ec0145174fab29fb8a9032489e
- Cited by
- 159
- References
- 33
- Citations by year
- 2026: 12 · 2025: 19 · 2024: 24 · 2023: 12 · 2022: 15 · 2021: 7 · 2020: 15 · 2019: 16 · 2018: 15 · 2017: 14 · 2016: 10
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Cancer Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Texas MD Anderson Cancer Center
- National Cancer Institute
- Topics
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Pharmaceutical studies and practices
- Health Sciences › Medicine › Oncology › Cancer Immunotherapy and Biomarkers
- Keywords
- targeted therapy, dose selection, dose-limiting toxicity, maximum tolerated dose, dose-ranging, pharmacodynamic biomarkers, target engagement, monoclonal antibodies, immunotherapy, anticancer drug development, hematologic malignancies, solid tumors
- MeSH terms
- Animals, Antineoplastic Agents, Dose-Response Relationship, Drug, Humans, Neoplasms, Prognosis, Biomarkers, Treatment Outcome, Maximum Tolerated Dose, Molecular Targeted Therapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.