Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 466

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Performance and Reproducibility of a Laser Fluorescence System for Detection of Occlusal Caries in vitro

Lussi, A., Imwinkelried, S., Pitts, N.B., Longbottom, C., Reich, E.·1999·Caries Research

Abstract

The diagnosis of occlusal caries at non–cavitated sites remains problematic, especially since clinical visual detection has limited sensitivity. Electrical methods of detection show considerable promise, but specificity is reduced. The aims of this in vitro study were: (1) to assess the validity of a new laser fluorescence device – the DIAGNOdent – (and compare the values with those of a fixed–frequency electrical device); (2) to determine the optimum cut–off points of the new device for different stages of the caries process, and (3) to assess the reproducibility of the new laser device. For validity and determination of optimum cut–off points, 105 extracted teeth with macroscopically intact occlusal surfaces were measured by a single examiner, using both the laser fluorescence device (on both moist and dried teeth) and an Electronic Caries Monitor. The teeth were subsequently examined histologically to determine the specificity, sensitivity and likelihood ratio at the D 2 (caries extending through more than half of the enamel thickness) and D 3 (caries involving dentin) levels. The values obtained for the laser device ranged from 0.72 to 0.87 (specificity), 0.76 to 0.87 (sensitivity) and 3.0 to 5.6 (likelihood ratio). Those for the ECM ranged from 0.64 to 0.78 (specificity), 0.87 to 0.92 (sensitivity) and 2.4 to 4.1 (likelihood ratio). To determine intra– and interexaminer reproducibility of the DIAGNOdent, 11 dentists recorded two different measurements at the same site on a separate set of 83 extracted molar teeth, and these were compared using Cohen’s kappa (at D 2 and D 3 levels) and Spearman’s correlation coefficient. The average intra–examiner kappa scores were 0.88 (D 2) and 0.90 (D 3), with a Spearman correlation of 0.97. For interexaminer reproducibility, the average kappa values were 0.65 (D 2) and 0.73 (D 3), with a Spearman correlation of 0.84. It is concluded that for occlusal caries (1) the new laser device has a higher diagnostic validity than the ECM, and (2) in vitro, measurements using the device are highly reproducible. Thus, the laser device could be a valuable tool for the longitudinal monitoring of caries and for assessing the outcome of preventive interventions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000016527

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 466

Metadata

Authors
Lussi, A., Imwinkelried, S., Pitts, N. B., Longbottom, C., & Reich, E.
Venue
Caries Research
Publisher
S. Karger AG
Published
1999
Volume
33
Issue
4
Pages
261-266
ISSN
  • 0008-6568 (ISSN-L)
  • 1421-976X
OpenAlex
W2051392017
Cited by
466
References
11
FWCI
21.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance and Reproducibility of a Laser Fluorescence System for Detection of Occlusal Caries in vitro. https://app.cochat.ai/papers/10.1159/000016527
The paper
Lussi, A., Imwinkelried, S., Pitts, N. B., Longbottom, C., & Reich, E. (1999). Performance and Reproducibility of a Laser Fluorescence System for Detection of Occlusal Caries in vitro. Caries Research. https://doi.org/10.1159/000016527

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.