The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Artifact Processing in Computerized Analysis of Sleep EEG – A Review
Abstract
Quantitative analysis of sleep EEG data can provide valuable additional information in sleep research. However, analysis of data contaminated by artifacts can lead to spurious results. Thus, the first step in realizing an automatic sleep analysis system is the implementation of a reliable and valid artifact processing strategy. This strategy should include: (1) high-quality recording techniques in order to minimize the occurrence of avoidable artifacts (e.g. technical artifacts); (2) artifact minimization procedures in order to minimize the loss of data by estimating the contribution of different artifacts in the EEG recordings, thus allowing the calculation of the ‘corrected’ EEG (e.g. ocular and ECG interference), and finally (3) artifact identification procedures in order to define epochs contaminated by remaining artifacts (e.g. movement and muscle artifacts). Therefore, after a short description of the types of artifacts in the sleep EEG and some typical examples obtained in different sleep stages, artifact minimization and identification procedures will be reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
A multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Metadata
- Authors
- Anderer, P., Roberts, S., Schlögl, A., Gruber, G., Klösch, G., Herrmann, W., Rappelsberger, P., Filz, O., Barbanoj, M. J., Dorffner, G., & Saletu, B.
- Venue
- Neuropsychobiology
- Publisher
- S. Karger AG
- Published
- 1999
- Volume
- 40
- Issue
- 3
- Pages
- 150-157
- ISSN
- 0302-282X (ISSN-L)
- 1423-0224
- OpenAlex
- W2024461528
- Cited by
- 161
- References
- 2
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artifact Processing in Computerized Analysis of Sleep EEG – A Review. https://app.cochat.ai/papers/10.1159/000026613
- The paper
- Anderer, P., Roberts, S., Schlögl, A., Gruber, G., Klösch, G., Herrmann, W., Rappelsberger, P., Filz, O., Barbanoj, M. J., Dorffner, G., & Saletu, B. (1999). Artifact Processing in Computerized Analysis of Sleep EEG – A Review. Neuropsychobiology. https://doi.org/10.1159/000026613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.