The DOI matches its Crossref record.
Fluctuations of Intraocular Pressure during the Day in Open-Angle Glaucoma, Normal-Tension Glaucoma and Normal Subjects
Abstract
Purpose: The aim of the present paper is to describe the variations in intraocular pressure (IOP) during the day in normals, in patients with primary open-angle glaucoma (POAG) and in patients with normal-tension glaucoma (NTG). IOP represents one of the most important risk factors for glaucoma. However the IOP value is not constant during the day and IOP fluctuation could influence the diagnostic and prognostic evaluation of the glaucomatous disease. Methods: For this purpose IOP was evaluated every 2 h from 8 a.m. to 8 p.m. in one randomized eye of 33 normal subjects, 95 POAG and 50 NTG patients. Results: The results show that the highest IOP values were detectable in the morning in all three groups. The lowest values were found in the early afternoon hours. These variations were most evident in POAG patients. The daily IOP fluctuations were directly proportional to IOP level. Conclusion: The study evidents that a single tonometric evaluation, especially if done in the first hours of the afternoon, is not sufficient to correctly evaluate the IOP-related risk in glaucoma patients. If the pressure peaks are important in determining the extent of glaucomatous damage in NTG patients IOP should not have an important role in optic nerve head damage. The use of diurnal curves seems to be mandatory for the assessment of IOP-related risk and of efficiency of the therapeutic approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial
Bengtsson, B., Leske, M. C., Hyman, L., & Heijl, A. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.07.060 · Cited by 454
Oxidative deoxyribonucleic acid damage in the eyes of glaucoma patients
Izzotti, A., Saccà, S. C., Cartiglia, C., & De Flora, S. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00114-1 · Cited by 305
Self-citationChronobiology, drug delivery, and chronotherapeutics
Smolensky, M. H., & Peppas, N. A. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.07.001 · Cited by 288
Zode, G. S., Kuehn, M. H., Nishimura, D. Y., Searby, C. C., Mohan, K., Grozdanic, S. D., Bugge, K., Anderson, M. G., Clark, A. F., Stone, E. M., et al. (2011) · Journal of Clinical Investigation · doi:10.1172/jci58183 · Cited by 268
Zode, G. S., Kuehn, M. H., Nishimura, D. Y., Searby, C. C., Mohan, K., Grozdanic, S. D., Bugge, K., Anderson, M. G., Clark, A. F., Stone, E. M., et al. (2015) · Journal of Clinical Investigation · doi:10.1172/jci82799 · Cited by 260
Metadata
- Authors
- Saccà, S. C., Rolando, M., Marletta, A., Macrì, A., Cerqueti, P., & Ciurlo, G.
- Venue
- Ophthalmologica
- Publisher
- S. Karger AG
- Published
- 1998
- Volume
- 212
- Issue
- 2
- Pages
- 115-119
- ISSN
- 0030-3755 (ISSN-L)
- 1423-0267
- OpenAlex
- W2032704621
- Cited by
- 183
- References
- 0
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluctuations of Intraocular Pressure during the Day in Open-Angle Glaucoma, Normal-Tension Glaucoma and Normal Subjects. https://app.cochat.ai/papers/10.1159/000027290
- The paper
- Saccà, S. C., Rolando, M., Marletta, A., Macrì, A., Cerqueti, P., & Ciurlo, G. (1998). Fluctuations of Intraocular Pressure during the Day in Open-Angle Glaucoma, Normal-Tension Glaucoma and Normal Subjects. Ophthalmologica. https://doi.org/10.1159/000027290
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.