Pharyngeal Cross-Sectional Area and Pharyngeal Compliance in Normal Males and Females
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Obstructive sleep apnea syndrome is ascribed to pharyngeal dysfunction, but there are only a few reports about the normal morphological values in this anatomical region. We measured the pharyngeal cross-sectional area and the compliance (collapsibility), using the acoustic reflection technique with air breathing, in 181 healthy subjects (age 21–69 years). We assessed their sex-related differences, and the effects of age, body size and body postures on these parameters. The pharyngeal cross-sectional area, defined as the region from the fauces to the glottis, posturally changed with successive decreases in the sitting, left lateral decubitus and supine positions. The area was significantly greater in male than in female subjects in the sitting position (p < 0.01), but no difference was present in the recumbent positions. The pharyngeal cross-sectional area did not correlate with either age or body size. The specific pharyngeal compliance was greater in the males than in the females (p < 0.01) and increased with age only in the male subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung Volume Dependence of Pharyngeal Cross-Sectional Area in Patients with Obstructive Sleep Apnea
Hoffstein, V., Zamel, N., & Phillipson, E. A. (1984) · American Review of Respiratory Disease · doi:10.1164/arrd.1984.130.2.175 · Cited by 332
Pharyngeal Size in Snorers, Nonsnorers, and Patients with Obstructive Sleep Apnea
Bradley, T. D., Brown, I. G., Grossman, R. F., Zamel, N., Martinez, D., Phillipson, E. A., & Hoffstein, V. (1986) · New England Journal of Medicine · doi:10.1056/nejm198611203152105 · Cited by 330
Horner, R. L., Innes, J. A., Murphy, K., & Guz, A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018536 · Cited by 291
Size and Mechanical Properties of the Pharynx in Healthy Men and Women
Brooks, L. J., & Strohl, K. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.6.1394 · Cited by 180
Cited by
Gender Differences in the Expression of Sleep-Disordered Breathing
Mohsenin, V. (2001) · Chest · doi:10.1378/chest.120.5.1442 · Cited by 265
Contributions of Upper Airway Mechanics and Control Mechanisms to Severity of Obstructive Apnea
Younes, M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200302-201oc · Cited by 259
Effects of gender on upper airway collapsibility and severity of obstructive sleep apnea
Mohsenin, V. (2003) · Sleep Medicine · doi:10.1016/s1389-9457(03)00168-0 · Cited by 142
Verin, E., Tardif, C., Buffet, X., Marie, J. P., Lacoume, Y., Andrieu-Guitrancourt, J., & Pasquis, P. (2002) · Respiration Physiology · doi:10.1016/s0034-5687(01)00324-3 · Cited by 48
Metadata
- Authors
- Huang, J., Shen, H., Takahashi, M., Fukunaga, T., Toga, H., Takahashi, K., & Ohya, N.
- Venue
- Respiration
- Publisher
- S. Karger AG
- Published
- 1998
- Volume
- 65
- Issue
- 6
- Pages
- 458-468
- ISSN
- 0025-7931 (ISSN-L)
- 1423-0356
- OpenAlex
- W2055331147
- Cited by
- 41
- References
- 4
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.