Abstract
In this study, we injected nanospheres containing a fluorescein derivative into the vitreous cavity of pigmented rabbit eyes and evaluated their intraocular kinetics as drug carriers in vivo. Polystyrene nanospheres (2 µm, 200 nm and 50 nm in diameter) containing a fluorescein derivative were used in this study. A suspension of each particle was prepared by diluting with distilled water at a concentration of 10 µg/ml equivalent to sodium fluorescein. The suspension of nanospheres was injected once into the vitreous cavity of unilateral eyes of pigmented rabbits. A sodium fluorescein solution of the same concentration was injected once into the vitreous cavity of the other eye as the control. The intraocular kinetics of nanospheres was evaluated by measuring vitreous fluorescence using a scanning fluorophotometer. To investigate elimination pathways of nanospheres in detail, serial cross-sections of the eyes were examined with a fluorescence microscope. The fluorescence derived from nanospheres was observed in the vitreous cavity for over 1 month (2 µm: t 1/2 = 5.4 ± 0.8 days, 200 nm: t 1/2 = 8.6 ± 0.7 days, 50 nm: t 1/2 = 10.1 ± 1.8 days), whereas that in the control eyes completely disappeared within 3 days (t 1/2 = 7.8 ± 0.7 h). The elimination half-life from the vitreous cavity correlated well with the particle diameter (r = –0.997, p = 0.007). Histological studies using a fluorescence microscope revealed that nanospheres with a diameter of 2 µm were seen in the vitreous cavity and trabecular meshwork, while nanospheres with a diameter of smaller than 200 nm were also observed in the retina as well as these tissues. Our findings indicated that nanospheres may be beneficial as a drug carrier to the retina, vitreous and trabecular meshwork.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Perspectives in Ocular Drug Delivery
Gaudana, R., Jwala, J., Boddu, S. H. S., & Mitra, A. K. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9694-0 · Cited by 605
Nanotechnology in ocular drug delivery
Sahoo, S. K., Dilnawaz, F., & Krishnakumar, S. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.021 · Cited by 510
Nanotechnology in Ocular Drug Delivery
Patel, D., Pathak, D., & Giradkar, P. (2021) · Nanocarriers: Drug Delivery System · doi:10.1007/978-981-33-4497-6_18 · Cited by 362
Bourges, J.-L., Gautier, S. E., Delie, F., Bejjani, R. A., Jeanny, J.-C., Gurny, R., BenEzra, D., & Behar-Cohen, F. F. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1068 · Cited by 357
Nanomedicines for back of the eye drug delivery, gene delivery, and imaging
Kompella, U. B., Amrite, A. C., Pacha Ravi, R., & Durazo, S. A. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.04.001 · Cited by 258
Metadata
- Authors
- Sakurai, E., Ozeki, H., Kunou, N., & Ogura, Y.
- Venue
- Ophthalmic Research
- Publisher
- S. Karger AG
- Published
- 2000-12-13
- Volume
- 33
- Issue
- 1
- Pages
- 31-36
- ISSN
- 0030-3747 (ISSN-L)
- 1423-0259
- OpenAlex
- W2058308524
- Cited by
- 155
- References
- 0
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Particle Size of Polymeric Nanospheres on Intravitreal Kinetics. https://app.cochat.ai/papers/10.1159/000055638
- The paper
- Sakurai, E., Ozeki, H., Kunou, N., & Ogura, Y. (2001). Effect of Particle Size of Polymeric Nanospheres on Intravitreal Kinetics. Ophthalmic Research. https://doi.org/10.1159/000055638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.