CoChat

Hardware-Related Complications after Placement of Thalamic Deep Brain Stimulator Systems

Kondziolka, Douglas, Whiting, Donald, Germanwala, Anand, Oh, Michael · 2002 · Stereotactic and Functional Neurosurgery
Cited by 137

The DOI matches its Crossref record.

Abstract

Deep brain stimulation (DBS) has become a common therapeutic approach to patients with movement disorders. We evaluated results from two centers in a large metropolitan area where DBS systems are implanted into the thalamus for patients with tremor. Although all implanted systems led to an improvement in tremor, morbidity related to the hardware system occurred. A total of 23 hardware problems were noted in 66 patients undergoing implantation of 66 DBS systems (27% of patients). The most common problem included breakage of the electrode lead in its extracranial location, system infection, battery or connector problems, lead migration, and hemorrhage. Management was tailored to the specific hardware-related problem. Modifications in both surgical technique and hardware design should reduce the incidence of complications. Surgeons who place DBS systems should be aware of the spectrum of problems that can be associated with the device and its placement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000070836

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kondziolka, D., Whiting, D., Germanwala, A., & Oh, M.
Venue
Stereotactic and Functional Neurosurgery
Publisher
S. Karger AG
Published
2002
Volume
79
Issue
3-4
Pages
228-233
ISSN
  • 1011-6125 (ISSN-L)
  • 1423-0372
OpenAlex
W2060925615
Cited by
137
References
0
FWCI
1.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.