Longevity of Batteries in Internal Pulse Generators Used for Deep Brain Stimulation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The longevity of batteries in internal pulse generators (IPGs) used clinically for deep brain stimulation is not known. We conducted a study to assess the life span of these batteries. From 1993 to 2000, 163 single-channel batteries were surgically implanted in our institution. The electrical settings utilized in patients who had battery failures were assessed and the total electrical energy delivered (TEED) was calculated and correlated with battery longevity. Fourteen IPGs had battery failure requiring replacement. The median life span of the batteries was 45 months. Batteries with high energy consumption as assessed by TEED had a reduced life span (r = –0.82, p ≤ 0.001). Patients with essential tremor who required battery replacement needed higher settings to control their symptoms and therefore presented a shorter battery life when compared to patients with Parkinson’s disease. In our series of patients who needed battery replacement, battery longevity varied with stimulation parameters but was longer than expected from the manufacturer’s specifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279
Cited by
Adaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374
“Conventional cDBS is associated with an average battery life of <4 years, with replacement usually necessitating general anesthesia and incurring substantial hardware costs.(25) Therefore, a halving of power consumption would reduce the number of replacement battery operations required, limiting surgical risk and sign…”
BackgroundDeep brain stimulation for essential tremor: a systematic review
Flora, E. D., Perera, C. L., Cameron, A. L., & Maddern, G. J. (2010) · Movement Disorders · doi:10.1002/mds.23195 · Cited by 323
Principles of electrical stimulation of neural tissue
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53497-2.00001-2 · Cited by 151
Giacobbe, P., Mayberg, H. S., & Lozano, A. M. (2009) · Experimental Neurology · doi:10.1016/j.expneurol.2009.04.028 · Cited by 112
Self-citationDeep brain stimulation: current and future perspectives
Awan, N. R., Lozano, A., & Hamani, C. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0982 · Cited by 83
Self-citation
Metadata
- Authors
- Bin-Mahfoodh, M., Hamani, C., Sime, E., & Lozano, A. M.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 2003
- Volume
- 80
- Issue
- 1-4
- Pages
- 56-60
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W1968772654
- Cited by
- 85
- References
- 1
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Longevity of Batteries in Internal Pulse Generators Used for Deep Brain Stimulation. https://app.cochat.ai/papers/10.1159/000075161
- The paper
- Bin-Mahfoodh, M., Hamani, C., Sime, E., & Lozano, A. M. (2003). Longevity of Batteries in Internal Pulse Generators Used for Deep Brain Stimulation. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000075161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.