The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
New developments in automated cytogenetic imaging: unattended scoring of dicentric chromosomes, micronuclei, single cell gel electrophoresis, and fluorescence signals
Abstract
The quantification of DNA damage, both in vivo and in vitro, can be very time consuming, since large amounts of samples need to be scored. Additional uncertainties may arise due to the lack of documentation or by scoring biases. Image analysis automation is a possible strategy to cope with these difficulties and to generate a new quality of reproducibility. In this communication we collected some recent results obtained with the automated scanning platform Metafer, covering applications that are being used in radiation research, biological dosimetry, DNA repair research and environmental mutagenesis studies. We can show that the automated scoring for dicentric chromosomes, for micronuclei, and for Comet assay cells produce reliable and reproducible results, which prove the usability of automated scanning in the above mentioned research fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
Rothkamm, K., & Löbrich, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0830918100 · Cited by 1,645
Cited by
Exit from dormancy provokes DNA-damage-induced attrition in haematopoietic stem cells
Walter, D., Lier, A., Geiselhart, A., Thalheimer, F. B., Huntscha, S., Sobotta, M. C., Moehrle, B., Brocks, D., Bayindir, I., Kaschutnig, P., et al. (2015) · Nature · doi:10.1038/nature14131 · Cited by 619
Chromosomal changes: induction, detection methods and applicability in human biomonitoring
Mateuca, R., Lombaert, N., Aka, P. V., Decordier, I., & Kirsch-Volders, M. (2006) · Biochimie · doi:10.1016/j.biochi.2006.07.004 · Cited by 367
Micronucleus Assay: The State of Art, and Future Directions
Sommer, S., Buraczewska, I., & Kruszewski, M. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21041534 · Cited by 324
Kirsch-Volders, M., Plas, G., Elhajouji, A., Lukamowicz, M., Gonzalez, L., Vande Loock, K., & Decordier, I. (2011) · Archives of Toxicology · doi:10.1007/s00204-011-0691-4 · Cited by 268
The micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure
Vral, A., Fenech, M., & Thierens, H. (2011) · Mutagenesis · doi:10.1093/mutage/geq078 · Cited by 262
Metadata
- Authors
- Schunck, C., Johannes, T., Varga, D., Lörch, T., & Plesch, A.
- Venue
- Cytogenetic and Genome Research
- Publisher
- S. Karger AG
- Published
- 2004
- Volume
- 104
- Issue
- 1-4
- Pages
- 383-389
- ISSN
- 1424-859X (ISSN-L)
- 1424-8581
- OpenAlex
- W2077343886
- Cited by
- 160
- References
- 1
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New developments in automated cytogenetic imaging: unattended scoring of dicentric chromosomes, micronuclei, single cell gel electrophoresis, and fluorescence signals. https://app.cochat.ai/papers/10.1159/000077520
- The paper
- Schunck, C., Johannes, T., Varga, D., Lörch, T., & Plesch, A. (2004). New developments in automated cytogenetic imaging: unattended scoring of dicentric chromosomes, micronuclei, single cell gel electrophoresis, and fluorescence signals. Cytogenetic and Genome Research. https://doi.org/10.1159/000077520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.