Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Mechanisms Regulating the Ductus Arteriosus

Clyman, Ronald I.·2006·Neonatology

Abstract

A patent ductus arteriosus (PDA) results in increased pulmonary blood flow and redistribution of flow to other organs. Several co-morbidities (i.e., necrotizing enterocolitis, intracranial hemorrhage, pulmonary edema/hemorrhage, bronchopulmonary dysplasia, and retinopathy) are associated with the presence of a PDA, but whether or not a PDA is responsible for their development is still unclear. In this review, comparative physiology between the full term and preterm newborn and the barriers preventing the necessary cascade of events leading to permanent constriction of the PDA are reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000092870

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 250

Metadata

Authors
Clyman, R. I.
Venue
Neonatology
Publisher
S. Karger AG
Published
2006
Volume
89
Issue
4
Pages
330-335
ISSN
  • 1661-7800 (ISSN-L)
  • 1661-7819
OpenAlex
W2161663034
Cited by
250
References
1
FWCI
10.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanisms Regulating the Ductus Arteriosus. https://app.cochat.ai/papers/10.1159/000092870
The paper
Clyman, R. I. (2006). Mechanisms Regulating the Ductus Arteriosus. Neonatology. https://doi.org/10.1159/000092870

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.