CoChat

Gastric Electrical Stimulation Is Safe and Effective: A Long-Term Study in Patients with Drug-Refractory Gastroparesis in Three Regional Centers

Anand, Curuchi, Al-Juburi, Amar, Familoni, Babajide, Rashed, Hani, Cutts, Teresa, Abidi, Nighat, Johnson, William D., Minocha, Anil, Abell, Thomas L. · 2007 · Digestion
Cited by 99

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Drug-refractory gastroparesis has previously been without acceptable alternative therapies. Although gastric electrical stimulation has been used for over a decade, no long-term multicenter data exist. Methods: We studied 214 consecutive drug-refractory patients with the symptoms of gastroparesis (146 idiopathic, 45 diabetic, 23 after surgery) who consented to participate in a variety of clinical research and clinical protocols at three centers from January 1992 through January 2005, resulting in 156 patients implanted with a gastric electrical stimulation device and the other 58 patients serving as controls. The patients were stratified into three groups: (1) consented but never permanently implanted; (2) implanted with permanent device, and (3) consented while awaiting a permanent device. The patients were followed over time for gastrointestinal symptoms, solid gastric emptying, health-related quality of life, survival, device retention, and complications. Demographics, descriptive statistics, and t tests were used for comparison between baseline and latest follow-up. Results: At latest follow-up, median 4 years for 5,568 patient months, most patients implanted (135 of 156) were alive with intact devices, significantly reduced gastrointestinal symptoms, and improved health-related quality of life, with evidence of improved gastric emptying, and 90% of the patients had a response in at least 1 of 3 main symptoms. Most patients explanted, usually for pocket infections, were later reimplanted successfully. There were no deaths directly related to the device. Conclusion: Based on this sample of patients, implanted with gastric electrical stimulation devices at three centers and followed for up toward a decade, gastric electrical stimulation for drug-refractory gastroparesis is both safe and effective.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000102961

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 99

Metadata

Authors
Anand, C., Al-Juburi, A., Familoni, B., Rashed, H., Cutts, T., Abidi, N., Johnson, W. D., Minocha, A., & Abell, T. L.
Venue
Digestion
Publisher
S. Karger AG
Published
2007
Volume
75
Issue
2-3
Pages
83-89
ISSN
  • 0012-2823 (ISSN-L)
  • 1421-9867
OpenAlex
W2046660901
Cited by
99
References
1
FWCI
6.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gastric Electrical Stimulation Is Safe and Effective: A Long-Term Study in Patients with Drug-Refractory Gastroparesis in Three Regional Centers. https://app.cochat.ai/papers/10.1159/000102961
The paper
Anand, C., Al-Juburi, A., Familoni, B., Rashed, H., Cutts, T., Abidi, N., Johnson, W. D., Minocha, A., & Abell, T. L. (2007). Gastric Electrical Stimulation Is Safe and Effective: A Long-Term Study in Patients with Drug-Refractory Gastroparesis in Three Regional Centers. Digestion. https://doi.org/10.1159/000102961

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.