Radioimmunoassay of Melatonin: Human Serum and Cerebrospinal Fluid

Arendt, J., Wetterberg, L., Heyden, T., Sizonenko, P.C., Paunier, L.·1977·Hormone Research

Abstract

Using a newly characterized anti-melatonin serum it has been possible to establish human serum melatonin concentrations at short time intervals during 24h. A clear circadian rhythm with peak values during the dark phase was demonstrated in both men and women. Values (pg/ml;mean +/- SE) were as follows: females 02.00h: 130 +/- 7, 18.00h: 45 +/- 5 males 02.00h: 140 +/- 11, 18,00H: 70 +/- 5. The estimation (pg/ml; mean +/- SE) of melatonin in human serum (males: 63 +/- 22 and females: 100 +/- 45) and cerebrospinal fluid simultaneously taken has shown that melatonin is lower in cerebrospinal fluid (males: 59 +/- 33 and females: 57 +/- 28). Blanks are not subtracted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000178782

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Arendt, J., Wetterberg, L., Heyden, T., Sizonenko, P. C., & Paunier, L.
Venue
Hormone Research
Publisher
S. Karger AG
Published
1977
Volume
8
Issue
2
Pages
65-75
ISSN
  • 0301-0163 (ISSN-L)
  • 1423-0046
OpenAlex
W2062190231
Cited by
164
References
0
FWCI
0.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radioimmunoassay of Melatonin: Human Serum and Cerebrospinal Fluid. https://app.cochat.ai/papers/10.1159/000178782
The paper
Arendt, J., Wetterberg, L., Heyden, T., Sizonenko, P. C., & Paunier, L. (1977). Radioimmunoassay of Melatonin: Human Serum and Cerebrospinal Fluid. Hormone Research. https://doi.org/10.1159/000178782

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.