Superiority of the Internal Jugular over the Subclavian Access for Temporary Dialysis
Abstract
We studied angiographically the access route 1-27 months after the insertion temporary dialysis catheters in 52 patients: 32 subclavian and 20 internal jugular. The two groups were statistically similar with respect to age, sex and race. The subclavian catheters were left in for a mean of 11.5 days (2-22) while the internal jugular ones were inserted for 15.8 days (5-25; p = 0.0015). One hundred percent of the internal jugular patients were free of any venogram abnormalities in their venous access return. In marked contrast, 50% of the subclavian sites had mild to severe stricutures with 90% having 70-100% occlusion of the subclavian vein. Six patients had bilateral severe strictures. The long-term stricture rate of subclavian catheters in the subclavian vein was unacceptably high compared to the internal jugular route.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Vascular access use in Europe and the United States: Results from the DOPPS
Pisoni, R. L., Young, E. W., Dykstra, D. M., Greenwood, R. N., Hecking, E., Gillespie, B., Wolfe, R. A., Goodkin, D. A., & Held, P. J. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00117.x · Cited by 851
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Metadata
- Authors
- Cimochowski, G. E., Worley, E., Rutherford, W. E., Sartain, J., Blondin, J., & Harter, H.
- Venue
- Nephron
- Publisher
- S. Karger AG
- Published
- 1990
- Volume
- 54
- Issue
- 2
- Pages
- 154-161
- ISSN
- 1660-8151 (ISSN-L)
- 2235-3186
- OpenAlex
- W1982603634
- Cited by
- 404
- References
- 0
- FWCI
- 28.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superiority of the Internal Jugular over the Subclavian Access for Temporary Dialysis. https://app.cochat.ai/papers/10.1159/000185837
- The paper
- Cimochowski, G. E., Worley, E., Rutherford, W. E., Sartain, J., Blondin, J., & Harter, H. (1990). Superiority of the Internal Jugular over the Subclavian Access for Temporary Dialysis. Nephron. https://doi.org/10.1159/000185837
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.