The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Review of Wireless and Wearable Electroencephalogram Systems and Brain-Computer Interfaces – A Mini-Review
Abstract
Biomedical signal monitoring systems have rapidly advanced in recent years, propelled by significant advances in electronic and information technologies. Brain-computer interface (BCI) is one of the important research branches and has become a hot topic in the study of neural engineering, rehabilitation, and brain science. Traditionally, most BCI systems use bulky, wired laboratory-oriented sensing equipments to measure brain activity under well-controlled conditions within a confined space. Using bulky sensing equipments not only is uncomfortable and inconvenient for users, but also impedes their ability to perform routine tasks in daily operational environments. Furthermore, owing to large data volumes, signal processing of BCI systems is often performed off-line using high-end personal computers, hindering the applications of BCI in real-world environments. To be practical for routine use by unconstrained, freely-moving users, BCI systems must be noninvasive, nonintrusive, lightweight and capable of online signal processing. This work reviews recent online BCI systems, focusing especially on wearable, wireless and real-time systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A different approach to the direct measurement of trembling legs or arms is to use the EEG signal in the framework of a Brain Computer Interface (BCI) [62].”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [62]
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,129
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M. J., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 820
A P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 726
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M. J., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637
A practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 622
Pfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
Support Vector Channel Selection in BCI
Lal, T., Schroder, M., Hinterberger, T., Weston, J., Bogdan, M., Birbaumer, N., & Schölkopf, B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827827 · Cited by 516
Leeb, R., Friedman, D. A., Muller-Putz, G. R., Scherer, R., Slater, M., & Pfurtscheller, G. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/79642 · Cited by 480
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 340
The Berlin brain-computer interface: EEG-based communication without subject training
Blankertz, B., Dornhege, G., Krauledat, M., Müller, K. R., Kunzmann, V., Losch, F., & Curio, G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875557 · Cited by 333
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 304
Xu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258
Ica: a potential tool for bci systems
Kachenoura, A., Albera, L., Senhadji, L., & Comon, P. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408442 · Cited by 226
A brain-computer interface with vibrotactile biofeedback for haptic information
Chatterjee, A., Aggarwal, V., Ramos‐Murguialday, A., Acharya, S., & Thakor, N. V. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-40 · Cited by 201
Vidaurre, C., Schloogl, A., Cabeza, R., Scherer, R., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873542 · Cited by 195
Lin, C., Chen, Y.-C., Huang, T., Chiu, T.-T., Ko, L., Liang, S., Hsieh, H.-Y., Hsu, S.-H., & Duann, J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.918566 · Cited by 184
Self-citationOnline Control of a Brain-Computer Interface Using Phase Synchronization
Brunner, C., Scherer, R., Graimann, B., Supp, G. G., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881775 · Cited by 168
Vibrotactile Feedback for Brain-Computer Interface Operation
Febo Cincotti, A., Kauhanen, L., Fabio Aloise, A., Palomäki, T., Caporusso, N., Jylänki, P., Donatella Mattia, A., Babiloni, F., Vanacker, G., Nuttin, M., et al. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/48937 · Cited by 160
Noninvasive Neural Prostheses Using Mobile and Wireless EEG
Lin, C., Ko, L., Chiou, J., Duann, J., Huang, R., Liang, S., Chiu, T.-W., & Jung, T. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922561 · Cited by 160
Self-citationP300-Based BCI Mouse With Genetically-Optimized Analogue Control
Citi, L., Poli, R., Cinel, C., & Sepulveda, F. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.913184 · Cited by 151
Information conveyed through brain-control: cursor versus robot
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814451 · Cited by 149
A multichannel telemetry system for single unit neural recordings
Obeid, I., Nicolelis, M. A. L., & Wolf, P. D. (2003) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.09.023 · Cited by 117
The Self-Paced Graz Brain-Computer Interface: Methods and Applications
Scherer, R., Schlögl, A., Lee, F., Bischof, H., Janša, J., & Pfurtscheller, G. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/79826 · Cited by 113
Single-Trial EEG Source Reconstruction for Brain–Computer Interface
Noirhomme, Q., Kitney, R. I., & Macq, B. M. M. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.913986 · Cited by 75
Hung, C., Lee, P., Wu, Y., Chen, L., Yeh, T., & Hsieh, J. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5772-1 · Cited by 75
Matthews, R., McDonald, N. J., Anumula, H., Woodward, J., Turner, P. J., Steindorf, M. A., Chang, K. K., & Pendleton, J. M. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-73216-7_16 · Cited by 55
Implementation of a telemonitoring system for the control of an EEG-based brain-computer interface
Müller, G., Neuper, C., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.810423 · Cited by 40
Data communication between brain implants and computer
Sun, M., Mickle, M. H., Wei, L., Liu, Q., & Sclabassi, R. J. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814421 · Cited by 39
Fatourechi, M., Birch, G. E., & Ward, R. K. (2007) · Journal of Computational Neuroscience · doi:10.1007/s10827-006-0017-3 · Cited by 20
Wireless system for long-term EEG monitoring of absence epilepsy
Whitchurch, A. K., Ashok, B. H., Kumaar, R. V., Saurkesi, K., & Varadan, V. K. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.473344 · Cited by 14
Cited by
Sorted by citations
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 451
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 393
Remote health monitoring of elderly through wearable sensors
Al-Khafajiy, M., Baker, T., Chalmers, C., Asim, M., Kolivand, H., Fahim, M., & Waraich, A. (2019) · Multimedia Tools and Applications · doi:10.1007/s11042-018-7134-7 · Cited by 393
Tattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 321
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
Metadata
- Authors
- Lin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P.
- Affiliations
- National Yang Ming Chiao Tung University (TW)
- University of California San Diego (US)
- Taipei Veterans General Hospital (TW)
- Venue
- Gerontology
- Publisher
- S. Karger AG
- Published
- 2009-07-25
- Volume
- 56
- Issue
- 1
- Pages
- 112-119
- ISSN
- 0304-324X (ISSN-L)
- 1423-0003
- OpenAlex
- W2018730537
- Cited by
- 133
- References
- 34
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 5 · 2023: 5 · 2022: 8 · 2021: 5 · 2020: 6 · 2019: 12 · 2018: 8 · 2017: 8 · 2016: 11 · 2015: 7 · 2014: 14 · 2013: 9 · 2012: 9
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Gerontology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council (NSC 97-2627-E-009-001)
- Shanghai Educational Development Foundation
- National Chiao Tung University
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- brain-computer interface, wearable EEG, wireless EEG, real-time signal processing, real-time BCI, neural engineering, rehabilitation
- MeSH terms
- Aged, Aging, Brain Diseases, Communication Devices for People with Disabilities, Communication Aids for Disabled, Electroencephalography, Humans, Telemetry, User-Computer Interface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review