Factors Involved in Validity Measurements of Diagnostic Tests for Approximal Caries – A Meta-Analysis
The DOI matches its Crossref record.
Abstract
In this study, a meta-analysis was performed on published validity parameters of visual inspection, radiographic examination and visual inspection upon fibre-optic transillumination (FOTI) in approximal caries diagnosis. It was the objective to investigate the influence of the diagnostic test, the study design and the validation method on reported validity. Sensitivities and specificities reported in the literature were transformed into D z values, representing the performance of a diagnostic method above chance, or of the observer using it, in a single parameter. D z values were neither statistically significantly different between visual inspection, radiographic examination and FOTI nor between ‘weak’ and ‘strong’ validation methods (p > 0.05). D z values obtained from in vivo studies were significantly different from those obtained from in vitro studies (p < 0.05), indicating that study design had a significant impact on the measurement of the validity of the evaluated test for approximal caries diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Assessing the quality of research.
Glasziou, P., Vandenbroucke, J., & Chalmers, I. (2004) · BMJ · doi:10.1136/bmj.328.7430.39 · Cited by 391
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
A systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Metadata
- Authors
- van Rijkom, H. M., & Verdonschot, E. H.
- Venue
- Caries Research
- Publisher
- S. Karger AG
- Published
- 2009-11-24
- Volume
- 29
- Issue
- 5
- Pages
- 364-370
- ISSN
- 0008-6568 (ISSN-L)
- 1421-976X
- OpenAlex
- W1994832294
- Cited by
- 43
- References
- 0
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- karger.com/pages/terms-and-conditions (vor)
- karger.com/pages/terms-and-conditions (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors Involved in Validity Measurements of Diagnostic Tests for Approximal Caries – A Meta-Analysis. https://app.cochat.ai/papers/10.1159/000262094
- The paper
- van Rijkom, H. M., & Verdonschot, E. H. (2009). Factors Involved in Validity Measurements of Diagnostic Tests for Approximal Caries – A Meta-Analysis. Caries Research. https://doi.org/10.1159/000262094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.