The DOI matches its Crossref record.
Reproducibility and Accuracy of Three Methods for Assessment of Demineralization Depth on the Occlusal Surface: An in vitro Examination
Abstract
This laboratory study of 100 occlusal surfaces investigated the reproducibility and accuracy of a visual ranked caries scoring system, an electronic caries scoring system (ECM) using a continuous conductance scale, and a radiographic ranked caries scoring system. Histological examination of the teeth served as a gold standard to validate the ability of each system to assess lesion depth and predict softened, demineralized dentine. After training, 3 examiners carried out each scoring system on two separate occasions. Kappa values for visual, ECM and radiographic ranked scoring systems showed good inter- and intra-examiner reproducibility levels and acceptable limits of agreement for ECM readings. When scoring systems were tabulated against histological scores there was a high correlation between the visual and ECM methods and lesion depth in both enamel and dentine, but radiographic examination could not detect enamel caries. When compared to the histological scoring, the Spearman correlation coefficients for the visual scoring ranged between 0.87 and 0.93, for the ECM between 0.80 and 0.85 and for the radiographic scoring system between 0.76 and 0.78. No tooth scored as visually sound had histological evidence of dentine caries. Soft dentine corresponded to demineralization involving the middle third of the dentine or more which was related to visual cavity formation or an ECM reading above 9 (score 3 or 4). The radiograph was an excellent predictor of soft dentine. In conclusion, the new visual system appears promising, but takes time to learn. The reproducibility and accuracy for the ECM is acceptable while radiographs miss early occlusal lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ismail, A. I., Sohn, W., Tellez, M., Amaya, A., Sen, A., Hasson, H., & Pitts, N. B. (2007) · Community Dentistry and Oral Epidemiology · doi:10.1111/j.1600-0528.2007.00347.x · Cited by 1,535
Pitts, N., Ekstrand, K., & The ICDAS Foundation (2013) · Community Dentistry and Oral Epidemiology · doi:10.1111/cdoe.12025 · Cited by 526
Self-citationSystematic Reviews of Selected Dental Caries Diagnostic and Management Methods
Bader, J. D., Shugars, D. A., & Bonito, A. J. (2001) · Journal of Dental Education · doi:10.1002/j.0022-0337.2001.65.10.tb03470.x · Cited by 327
Reproducibility and Accuracy of the ICDAS-II for Detection of Occlusal Caries in vitro
Jablonski-Momeni, A., Stachniss, V., Ricketts, D. N., Heinzel-Gutenbrunner, M., & Pieper, K. (2008) · Caries Research · doi:10.1159/000113160 · Cited by 289
Self-citationDetection and diagnosis of the early caries lesion
Gomez, J. (2015) · BMC Oral Health · doi:10.1186/1472-6831-15-s1-s3 · Cited by 284
Metadata
- Authors
- Ekstrand, K. R., Ricketts, D. N. J., & Kidd, E. A. M.
- Venue
- Caries Research
- Publisher
- S. Karger AG
- Published
- 1997
- Volume
- 31
- Issue
- 3
- Pages
- 224-231
- ISSN
- 0008-6568 (ISSN-L)
- 1421-976X
- OpenAlex
- W2005959725
- Cited by
- 424
- References
- 0
- FWCI
- 33.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility and Accuracy of Three Methods for Assessment of Demineralization Depth on the Occlusal Surface: An in vitro Examination. https://app.cochat.ai/papers/10.1159/000262404
- The paper
- Ekstrand, K. R., Ricketts, D. N. J., & Kidd, E. A. M. (1997). Reproducibility and Accuracy of Three Methods for Assessment of Demineralization Depth on the Occlusal Surface: An in vitro Examination. Caries Research. https://doi.org/10.1159/000262404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.