Three-Dimensional Computed Tomography Imaging of the Eustachian Tube Lumen in Patients with Patulous Eustachian Tube
The DOI matches its Crossref record.
Abstract
Background: The eustachian tube (ET) has a complicated anatomy, which is related to middle ear pathology. The anatomy of the ET has been well investigated in cadavers, but may not accurately reflect that in living subjects. Three-dimensional (3D) computed tomography (CT) was used to examine the ET in patients with patulous ET. Method: The subjects were 35 patients (17 males, aged 59 ± 16 years, and 18 females, aged 44 ± 15 years) with patulous ET which could be continuously traced from the pharyngeal orifice to the tympanic orifice (53 ears). CT was performed in the sitting position at rest, followed by 3D reconstruction. The course of the ET from the middle ear to the pharynx was visualized in 3D surface images. Morphological measurements of the curvature angle (angle C) and the inclination angle (angle I) were determined from 3D coordinates on the CT images. Results: The full length of the ET could be visualized in most patients suffering from patulous ET in the sitting position. Angle C was 21.7 ± 5.8° in the patients aged <40 years (n = 20), which is significantly larger than 16.7 ± 6.8° in the patients aged >59 years (n = 18; Student’s t test, p < 0.05). Angle I was 26.5 ± 4.2° in the patients aged <40 years (n = 20), also significantly larger than 21.6 ± 5.8° in the patients aged >59 years (n = 18; Student’s t test, p < 0.05). Conclusion: CT in the sitting position is a potential diagnostic tool of the ET and middle ear pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sitting 3-D CT is useful in the diagnosis of PET as shown in earlier studies [14–16, 22, 23].”
From The characteristic of patulous eustachian tube patients diagnosed by the JOS diagnostic criteria (2019) · cites this paper as [16]
In the citing paper
“Sitting 3-D CT is useful in the diagnosis of PET as shown in earlier studies [14–16, 22, 23].”
From The characteristic of patulous eustachian tube patients diagnosed by the JOS diagnostic criteria (2019) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- 10.1016%2FS0196-0709%2887%2980005-4 · DOI
- 10.1080%2F00016489850182549 · doi:10.1080/00016489850182549
- 10.1080%2F00016480410017422 · DOI · Paper page
- 10.1097%2F01.mao.0000253280.10501.72 · DOI · Paper page
- 10.1016%2FS0385-8146%2803%2900006-3 · doi:10.1016/s0385-8146(03)00006-3
- 10.1080%2F00016480701596054 · DOI
- 10.1097%2F00005537-199910000-00024 · doi:10.1097/00005537-199910000-00024
- 10.1001%2Farchotol.1967.00760050505008 · DOI
- 10.1097%2F00129492-200401000-00001 · DOI · Paper page
- 10.1097%2F01.mlg.0000246227.65877.1f · DOI · Paper page
- 10.1080%2F00016480510038167 · doi:10.1080/00016480510038167
Cited by
The characteristic of patulous eustachian tube patients diagnosed by the JOS diagnostic criteria
Kawamura, Y., Ikeda, R., Kikuchi, T., Miyazaki, H., Kawase, T., Katori, Y., & Kobayashi, T. (2019) · PLOS ONE · doi:10.1371/journal.pone.0226908 · Cited by 35
Self-citation
Metadata
- Authors
- Kikuchi, T., Oshima, T., Hori, Y., Kawase, T., & Kobayashi, T.
- Venue
- ORL
- Publisher
- S. Karger AG
- Published
- 2009
- Volume
- 71
- Issue
- 6
- Pages
- 312-316
- ISSN
- 0301-1569
- 1423-0275
- Cited by
- 24
- References
- 0
- Language
- en
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.