CoChat

Computer-Assisted Sleep Classification according to the Standard of the American Academy of Sleep Medicine: Validation Study of the AASM Version of the Somnolyzer 24 × 7

Anderer, Peter, Moreau, Arnaud, Woertz, Michael, Ross, Marco, Gruber, Georg, Parapatics, Silvia, Loretz, Erna, Heller, Esther, Schmidt, Andrea, Boeck, Marion, Moser, Doris, Kloesch, Gerhard, Saletu, Bernd, Saletu-Zyhlarz, Gerda M., Danker-Hopfe, Heidi, Zeitlhofer, Josef, Dorffner, Georg · 2010 · Neuropsychobiology
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: In 2007, the AASM Manual for the Scoring of Sleep and Associated Events was published by the American Academy of Sleep Medicine (AASM). Concerning the visual classification of sleep stages, these new rules are intended to replace the rules by Rechtschaffen and Kales (R&K). Methods: We adapted the automatic R&K sleep scoring system Somnolyzer 24 × 7 to comply with the AASM rules and subsequently performed a validation study based on 72 polysomnographies from the Siesta database (56 healthy subjects, 16 patients, 38 females, 34 males, aged 21–86 years). Scorings according to the AASM rules were performed manually by experienced sleep scorers and semi-automatically by the AASM version of the Somnolyzer. Manual scorings and Somnolyzer reviews were performed independently by at least 2 out of 8 experts from 4 sleep centers. Results: In the quality control process, sleep experts corrected 4.8 and 3.7% of the automatically assigned epochs, resulting in a reliability between 2 Somnolyzer-assisted scorings of 99% (Cohen’s kappa: 0.99). In contrast, the reliability between the 2 manual scorings was 82% (kappa: 0.76). The agreement between the 2 Somnolyzer-assisted and the 2 visual scorings was between 81% (kappa: 0.75) and 82% (kappa: 0.76). Conclusion: The AASM version of the Somnolyzer revealed an agreement between semi-automated and human expert scoring comparable to that published for the R&K version with a validity comparable to that of human experts, but with a reliability close to 1, thereby reducing interrater variability as well as scoring time to a minimum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000320864

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Anderer, P., Moreau, A., Woertz, M., Ross, M., Gruber, G., Parapatics, S., Loretz, E., Heller, E., Schmidt, A., Boeck, M., Moser, D., Kloesch, G., Saletu, B., Saletu-Zyhlarz, G. M., Danker-Hopfe, H., Zeitlhofer, J., & Dorffner, G.
Venue
Neuropsychobiology
Publisher
S. Karger AG
Published
2010
Volume
62
Issue
4
Pages
250-264
ISSN
  • 0302-282X (ISSN-L)
  • 1423-0224
OpenAlex
W2075412305
Cited by
115
References
1
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.