The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Steroid-Induced Iatrogenic Glaucoma
Open accessAbstract
Steroids in susceptible individuals can cause a clinical condition similar to primary open-angle glaucoma. Five percent of the population are high steroid responders and develop an intraocular pressure (IOP) elevation of more than 15 mm Hg above baseline. IOP elevation may occur as early as 1 day to as late as 12 weeks after intravitreal triamcinolone in 20–65% of patients. On average, 75% of eyes with steroid implants require IOP-lowering therapy at some point within 3 years of follow-up. The exact mechanism of steroid-induced glaucoma is not totally understood, but decreased trabecular meshwork outflow is regarded as the main cause of IOP elevation. High-risk patients who receive steroids should be monitored closely and if they develop elevated IOP, steroids with lower potency or steroid-sparing agents should be used. The IOP usually returns to normal within 2–4 weeks after stopping the steroid. About 1–5% of patients do not respond to medical therapy and need surgery. Trabeculectomy, trabeculotomy, shunt surgery, and cyclodestructive procedures are among the methods employed. Removal of residual sub-Tenon or intravitreal steroids may help hasten the resolution of the steroid response. Early results with anecortave acetate, an analog of cortisol acetate with antiangiogenic activity, in controlling IOP have been promising.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fanning, A. S., Jameson, B. J., Jesaitis, L. A., & Anderson, J. M. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.45.29745 · Cited by 1,432
Cited by
Diagnosis and Management of Infantile Hemangioma
Darrow, D. H., Greene, A. K., Mancini, A. J., Nopper, A. J., the SECTION ON DERMATOLOGY, S. O. O. A. N. S., Antaya, R. J., Cohen, B., Drolet, B. A., Fay, A., Fishman, S. J., et al. (2015) · Pediatrics · doi:10.1542/peds.2015-2485 · Cited by 293
Gaballa, S. A., Kompella, U. B., Elgarhy, O., Alqahtani, A. M., Pierscionek, B., Alany, R. G., & Abdelkader, H. (2021) · Drug Delivery and Translational Research · doi:10.1007/s13346-020-00843-z · Cited by 255
Lambert, W. S., Carlson, B. J., Formichella, C. R., Sappington, R. M., Ahlem, C., & Calkins, D. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00045 · Cited by 31
“Also, HE3286 treatment did not elevate IOP (Figure 1), which other steroids can do (Razeghinejad and Katz, 2012).”
Background
Metadata
- Authors
- Razeghinejad, M. R., & Katz, L. J.
- Venue
- Ophthalmic Research
- Publisher
- S. Karger AG
- Published
- 2011-07-13
- Volume
- 47
- Issue
- 2
- Pages
- 66-80
- ISSN
- 0030-3747 (ISSN-L)
- 1423-0259
- OpenAlex
- W1528523709
- Cited by
- 251
- References
- 1
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.