Improved Automated Screening of Diabetic Retinopathy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aim: To assess a two-step automated system (RetmarkerSR) that analyzes retinal photographs to detect diabetic retinopathy for the purpose of reducing the burden of manual grading. Methods: Anonymous images from 5,386 patients screened in 2007 were obtained from a nonmydriatic diabetic retinopathy screening program in Portugal and graded by an experienced ophthalmologist. RetmarkerSR earmarked microaneurysms, generating two outputs: ‘disease’ or ‘no disease’. A second-step analysis, based on coregistration, combining two visits, was subsequently performed in 289 patients who underwent repeated examinations in 2008. The study was extended by analyzing all referrals considered urgent by the ophthalmologist from 2001 to 2007. Results were compared with those obtained by manual grading. Results: The RetmarkerSR classified in a first-step analysis 2,560 patients (47.5%) as having ‘no disease’ and 2,826 patients (52.5%) as having ‘disease’, thus requiring manual grading. RetmarkerSR detected all eyes considered urgent referrals. The two-step analysis further reduced the number of false-positive results by 26.3%, indicating an overall sensitivity of 95.8% and a specificity of 63.2%. Conclusion: Automated grading of diabetic retinopathy may safely reduce the burden of grading patients in diabetic retinopathy screening programs. The novel two-step automated analysis system offers improved sensitivity and specificity over published automated analysis systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How Effective Are Treatments for Diabetic Retinopathy?
Ferris, F. L. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500100088034 · Cited by 392
Cited by
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
van der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13613 · Cited by 296
“The sensitivity of the IDx-DR device based on EURODIAB was comparable to the other algorithms while specificity of the IDx-DR device was similar or higher compared to these algorithms (Hansen et al. 2004; Philip et al. 2007; Oliveira et al. 2011).”
Real-Time Ultrawide Field Image Evaluation of Retinopathy in a Diabetes Telemedicine Program
Silva, P. S., Cavallerano, J. D., Tolson, A. M., Rodriguez, J., Rodriguez, S., Ajlan, R., Tolls, D., Patel, B., Sehizadeh, M., Thakore, K., et al. (2015) · Diabetes Care · doi:10.2337/dc15-0161 · Cited by 45
Metadata
- Authors
- Oliveira, C. M., Cristóvão, L. M., Ribeiro, M. L., & Abreu, J. R. F.
- Venue
- Ophthalmologica
- Publisher
- S. Karger AG
- Published
- 2011
- Volume
- 226
- Issue
- 4
- Pages
- 191-197
- ISSN
- 0030-3755 (ISSN-L)
- 1423-0267
- OpenAlex
- W1982390886
- Cited by
- 59
- References
- 1
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Automated Screening of Diabetic Retinopathy. https://app.cochat.ai/papers/10.1159/000330285
- The paper
- Oliveira, C. M., Cristóvão, L. M., Ribeiro, M. L., & Abreu, J. R. F. (2011). Improved Automated Screening of Diabetic Retinopathy. Ophthalmologica. https://doi.org/10.1159/000330285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.