Variation in Deep Brain Stimulation Electrode Impedance over Years Following Electrode Implantation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Deep brain stimulation (DBS) electrode impedance is a major determinant of current delivery to target tissues, but long-term variation in impedance has received little attention. Objectives: To assess the relationship between electrode impedance and time in a large DBS patient population and characterize the relationship between contact activity and impedance. Methods: We collected retrospective impedance and programming data from 128 electrodes in 84 patients with Parkinson's disease, essential tremor or dystonia. Effects of time, contact activity, stimulation voltage and other parameters on impedance were assessed. We also examined impedance changes following contact activation and deactivation. Results: Impedance decreased by 73 Ω/year (p < 0.001), with 72% of contacts following a downward trend. Impedance was on average 163 Ω lower in active contacts (p < 0.001). Contact activation and inactivation were associated with a more (p < 0.001) and less (p = 0.016) rapid decline in impedance, respectively. Higher stimulation voltages were associated with lower impedance values (p < 0.001). Contact number and electrode model were also significant predictors of impedance. Conclusions: Impedance decreases gradually in a stimulation-dependent manner. These trends have implications for long-term programming, the development of a closed-loop DBS device and current understanding of the electrode-tissue interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853
Cited by
Salanova, V., Sperling, M. R., Gross, R. E., Irwin, C. P., Vollhaber, J. A., Giftakis, J. E., Fisher, R. S., & SANTÉ Study Group (2021) · Epilepsia · doi:10.1111/epi.16895 · Cited by 333
Tan, H., Debarros, J., He, S., Pogosyan, A., Aziz, T. Z., Huang, Y., Wang, S., Timmermann, L., Visser-Vandewalle, V., Pedrosa, D. J., et al. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.02.011 · Cited by 83
Endovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
“Furthermore, surgically implanted electrodes induce chronic inflammation at the electrode-tissue interface, leading to changes in electrical impedance and signal degradation over time (12, 13).”
Background
Metadata
- Authors
- Satzer, D., Lanctin, D., Eberly, L. E., & Abosch, A.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 2014
- Volume
- 92
- Issue
- 2
- Pages
- 94-102
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W2004070622
- Cited by
- 91
- References
- 1
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.