The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Heart Rate Assessment Immediately after Birth
Abstract
Background: Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. Objective: The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. Methods: PubMed, EMBASE and Google Scholar were systematically searched using the following terms: ‘infant', ‘heart rate', ‘monitoring', ‘delivery room', ‘resuscitation', ‘stethoscope', ‘auscultation', ‘palpation', ‘pulse oximetry', ‘electrocardiogram', ‘Doppler ultrasound', ‘photoplethysmography' and ‘wearable sensors'. Results: Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Conclusion: Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peberdy, M. A., Callaway, C. W., Neumar, R. W., Geocadin, R. G., Zimmerman, J. L., Donnino, M., Gabrielli, A., Silvers, S. M., Zaritsky, A. L., Merchant, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971002 · Cited by 2,522
Callaway, C. W., Soar, J., Aibiki, M., Böttiger, B. W., Brooks, S. C., Deakin, C. D., Donnino, M. W., Drajer, S., Kloeck, W., Morley, P. T., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000273 · Cited by 1,390
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
A proposal for a new method of evaluation of the newborn infant.
APGAR, V. (1953) · PubMed · Cited by 787
Part 11: Neonatal resuscitation
Wyllie, J., Perlman, J. M., Kattwinkel, J., Atkins, D. L., Chameides, L., Goldsmith, J. P., Guinsburg, R., Hazinski, M. F., Morley, C., Richmond, S., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.029 · Cited by 601
Defining the Reference Range for Oxygen Saturation for Infants After Birth
Dawson, J. A., Kamlin, C. O. F., Vento, M., Wong, C., Cole, T. J., Donath, S. M., Davis, P. G., & Morley, C. J. (2010) · Pediatrics · doi:10.1542/peds.2009-1510 · Cited by 553
Kattwinkel, J., Perlman, J. M., Aziz, K., Colby, C., Fairchild, K., Gallagher, J., Hazinski, M. F., Halamek, L. P., Kumar, P., Little, G., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971119 · Cited by 498
Self-citationA Proposal for a New Method of Evaluation of the Newborn Infant
Apgar, V. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31829bdc5c · Cited by 236
Accuracy of clinical assessment of infant heart rate in the delivery room
Kamlin, C. O. F., O’Donnell, C. P. F., Everest, N. J., Davis, P. G., & Morley, C. J. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2006.04.015 · Cited by 216
Changes in heart rate in the first minutes after birth
Dawson, J. A., Kamlin, C., Wong, C., Pas, A. B. T., Vento, M., Cole, T. J., Donath, S. M., Hooper, S. B., Davis, P. G., & Morley, C. J. (2010) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/adc.2009.169102 · Cited by 190
Accuracy of Pulse Oximetry Measurement of Heart Rate of Newborn Infants in the Delivery Room
Kamlin, C. O. F., Dawson, J. A., O'Donnell, C. P. F., Morley, C. J., Donath, S. M., Sekhon, J., & Davis, P. G. (2008) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2008.01.002 · Cited by 180
Myerburg, R. J., Halperin, H., Egan, D. A., Boineau, R., Chugh, S. S., Gillis, A. M., Goldhaber, J. I., Lathrop, D. A., Liu, P., Niemann, J. T., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.004490 · Cited by 166
Pulse Oximetry Measures a Lower Heart Rate at Birth Compared with Electrocardiography
van Vonderen, J. J., Hooper, S. B., Kroese, J. K., Roest, A. A. W., Narayen, I. C., van Zwet, E. W., & Pas, A. B. T. (2014) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2014.09.015 · Cited by 153
Miao, F., Cheng, Y., He, Y., He, Q., & Li, Y. (2015) · Sensors · doi:10.3390/s150511465 · Cited by 143
ILCOR Advisory Statement: Resuscitation of the Newly Born Infant
Kattwinkel, J., Niermeyer, S., Nadkarni, V., Tibballs, J., Phillips, B., Zideman, D. A., Reempts, P. V., & Osmond, M. H. (1999) · Circulation · doi:10.1161/01.cir.99.14.1927 · Cited by 135
Determination of heart rate in the baby at birth
Owen, C. J., & Wyllie, J. P. (2004) · Resuscitation · doi:10.1016/j.resuscitation.2003.10.002 · Cited by 133
An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry
Haahr, R. G., Duun, S., Toft, M. H., Belhage, B., Larsen, J. O., Birkelund, K., & Thomsen, E. V. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2164247 · Cited by 102
Grubb, M., Carpenter, J., Crowe, J. A., Teoh, J. Y., Marlow, N., Ward, C., Mann, C., Sharkey, D., & Hayes‐Gill, B. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/881 · Cited by 56
Principles of pulse oximetry and its clinical application in neonatal medicine
Tin, W., & Lal, M. K. (2015) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2015.01.006 · Cited by 52
Detection of structural abnormalities in the first trimester using ultrasound
Blaas, H.-G. K. (2013) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2013.11.004 · Cited by 49
Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit
Singh, J. K., Kamlin, C. O. F., Morley, C. J., O’Donnell, C. P., Donath, S. M., & Davis, P. G. (2007) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2007.01250.x · Cited by 27
OLAM: A wearable, non-contact sensor for continuous heart-rate and activity monitoring
Albright, R. K., Goska, B. J., Hagen, T. M., Chi, M. Y., Cauwenberghs, G., & Chiang, P. Y. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091361 · Cited by 21
Application of phonocardiography on preterm infants with patent ductus arteriosus
Balogh, A. T., & Kovács, F. (2011) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.05.009 · Cited by 17
Implementation of a Wireless Sensor Network for Heart Rate Monitoring in a Senior Center
Huang, J.-H., Su, T.-Y., Raknim, P., & Lan, K.-C. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2014.0081 · Cited by 7
Cited by
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
European Consensus Guidelines on the Management of Respiratory Distress Syndrome – 2019 Update
Sweet, D. G., Carnielli, V., Greisen, G., Hallman, M., Ozek, E., te Pas, A., Plavka, R., Roehr, C. C., Saugstad, O. D., Simeoni, U., et al. (2019) · Neonatology · doi:10.1159/000499361 · Cited by 1,613
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
The Spectrum of Epidemiology Underlying Sudden Cardiac Death
Hayashi, M., Shimizu, W., & Albert, C. M. (2015) · Circulation Research · doi:10.1161/circresaha.116.304521 · Cited by 719
European Consensus Guidelines on the Management of Respiratory Distress Syndrome: 2022 Update
Sweet, D. G., Carnielli, V. P., Greisen, G., Hallman, M., Klebermass-Schrehof, K., Ozek, E., te Pas, A., Plavka, R., Roehr, C. C., Saugstad, O. D., et al. (2023) · Neonatology · doi:10.1159/000528914 · Cited by 704
Metadata
- Authors
- Phillipos, E., Solevåg, A. L., Pichler, G., Aziz, K., van Os, S., O''Reilly, M., Cheung, P.-Y., & Schmölzer, G. M.
- Venue
- Neonatology
- Publisher
- S. Karger AG
- Published
- 2015-12-19
- Volume
- 109
- Issue
- 2
- Pages
- 130-138
- ISSN
- 1661-7800 (ISSN-L)
- 1661-7819
- OpenAlex
- W2199185488
- Cited by
- 531
- References
- 24
- FWCI
- 28.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.