CoChat

First Human Use of a New Robotic-Assisted Fiber Optic Sensing Navigation System for Small Peripheral Pulmonary Nodules

Fielding, David I.K., Bashirzadeh, Farzad, Son, Jung Hwa, Todman, Maryann, Chin, Adrian, Tan, Lionel, Steinke, Karin, Windsor, Morgan N., Sung, Arthur Wai · 2019 · Respiration
Cited by 190

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position. Objectives: The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1–3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system. Methods: Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure. Results: The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%. Conclusion: This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000498951

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 190

Metadata

Authors
Fielding, D. I. K., Bashirzadeh, F., Son, J. H., Todman, M., Chin, A., Tan, L., Steinke, K., Windsor, M. N., & Sung, A. W.
Venue
Respiration
Publisher
S. Karger AG
Published
2019
Volume
98
Issue
2
Pages
142-150
ISSN
  • 0025-7931 (ISSN-L)
  • 1423-0356
OpenAlex
W2964668256
Cited by
190
References
1
FWCI
13.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.