Cited by 32Optical Imaging and Spectroscopy TechniquesMedical Imaging Techniques and ApplicationsHemodynamic Monitoring and Therapy

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Application of Fluorescent Dyes in Visceral Surgery: State of the Art and Future Perspectives

Open access

Abstract

Background: Through the improvement and implementation of advanced intraoperative imaging, the indications for intraoperative fluorescence have spread to various fields of visceral surgery. Indocyanine green (ICG)-based fluorescence angiography and the imaging systems using this certain dye are currently the cornerstone of intraoperative, fluorescence-based medical imaging. Summary: The article focuses on principles and approaches of intraoperative fluorescence in general surgery. The current clinical practice of intraoperative fluorescence and its evidence are described. Emerging new fields of application are put in a perspective. Furthermore, the technique and possible pit-falls in the performance of intraoperative ICG fluorescence angiography are described in this review article. Key Messages: Overall growing evidence suggests that intraoperative fluorescence imaging delivers valuable additional information to the surgeon, which might help to perform surgery more exactly and reduce perioperative complications. Perfusion assessment can be a helpful tool when performing critical anastomoses. There is evidence from prospective and randomized trials for the benefit of intraoperative ICG fluorescence angiography during esophageal reconstruction, colorectal surgery, and surgery for mesenteric ischemia. Most studies suggest the administration of 2.5–10 mg of ICG. Standardized settings and documentation are essential. The benefit of ICG fluorescence imaging for gastrointestinal sentinel node detection and detection of liver tumors and colorectal metastases of the liver cannot clearly be estimated duo to the small number of prospective studies. Critical points in the use of intraoperative fluorescence imaging remain the low standardization and reproducibility of the results and the associated difficulty in comparing the results of the existing trials. Furthermore, little is known about the influence of hemodynamic parameters on the quantitative assessment of ICG fluorescence during surgery.

Overview

Integrity signals

Registry

Crossref · 10.1159/000506910

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 54

  1. 10.1007/s00464-016-5181-6 · DOI
  2. 10.1111/micc.12392 · DOI
  3. 10.1016/j.pdpdt.2019.10.007 · DOI
  4. 10.1002/bjs.10783 · DOI
  5. 10.1177/1457496919877581 · DOI
  6. 10.1117/1.JBO.21.8.080901 · DOI
  7. 10.1364/OL.41.001173 · DOI
  8. 10.1002/anie.200901916 · DOI
  9. 10.1038/nbt.1764 · DOI
  10. 10.1158/0008-5472.CAN-08-3116 · DOI
  11. 10.1016/j.athoracsur.2014.07.050 · DOI
  12. 10.1155/2012/940585 · DOI
  13. 10.1111/j.1600-0773.1998.tb01945.x · DOI
  14. 10.1039/C8PP00064F · DOI
  15. 10.1093/clinchem/33.6.765 · DOI
  16. 10.1152/jappl.1970.29.2.181 · DOI
  17. 10.1088/0031-9155/23/1/017 · DOI
  18. 10.1007/s00423-016-1400-9 · DOI
  19. 10.1007/s10151-017-1731-8 · DOI
  20. 10.1016/j.jamcollsurg.2014.09.015 · DOI
  21. 10.1002/bjs.10844 · DOI
  22. 10.1111/codi.14257 · DOI
  23. 10.1007/s00595-009-4140-4 · DOI · Paper page
  24. 10.1007/s00464-014-3592-9 · DOI
  25. 10.1007/s00464-018-6226-9 · DOI · Paper page
  26. 10.1111/j.1399-6576.2005.00834.x · DOI
  27. 10.1007/s00534-009-0160-0 · DOI
  28. 10.1007/s10877-017-0073-4 · DOI
  29. 10.1161/CIRCULATIONAHA.106.655936 · DOI
  30. 10.1097/SLA.0000000000000811 · DOI
  31. 10.1007/s00464-018-6503-7 · DOI
  32. 10.21037/jtd.2019.01.30 · DOI
  33. 10.1002/cncr.24291 · DOI
  34. 10.1007/s00268-010-0764-1 · DOI
  35. 10.1111/hpb.12057 · DOI
  36. 10.1002/cncr.28203 · DOI
  37. 10.1245/s10434-013-3360-4 · DOI
  38. 10.1007/s00464-013-3305-9 · DOI
  39. 10.1097/SLA.0000000000000775 · DOI
  40. 10.1007/s00432-016-2267-4 · DOI
  41. 10.1245/s10434-015-4801-z · DOI
  42. 10.1002/jso.24701 · DOI
  43. 10.23736/S0393-2249.17.02932-0 · DOI
  44. 10.1007/s10147-016-1064-z · DOI
  45. 10.1016/S1470-2045(18)30448-0 · DOI
  46. 10.6004/jnccn.2019.0001 · DOI
  47. 10.1159/000108323 · DOI
  48. 10.1007/s00464-011-1854-3 · DOI
  49. 10.1002/jso.24318 · DOI
  50. 10.3748/wjg.v25.i31.4502 · DOI
  51. 10.1016/j.jtcvs.2016.04.025 · DOI
  52. 10.1002/jso.25285 · DOI
  53. 10.1007/s10151-019-02107-6 · DOI
  54. 10.1016/S2468-1253(17)30395-3 · DOI

Cited by

Sorted by citations

Metadata

Authors
Nowak, K., Karampinis, I., & Gerken, A. L. H.
Affiliations
  • RoMed Kliniken (DE)
  • University Medical Centre Mannheim (DE)
Venue
Visceral Medicine
Publisher
S. Karger AG
Published
2020
Volume
36
Issue
2
Pages
80-87
ISSN
  • 2297-4725 (ISSN-L)
  • 2297-475X
OpenAlex
W3013266050
Cited by
32
References
1
Citations by year
2026: 3 · 2025: 6 · 2024: 5 · 2023: 3 · 2022: 8 · 2021: 5 · 2020: 2
FWCI
0.66
Type
journal article
Language
en
Open access
Locations
  • Visceral Medicine (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
intraoperative fluorescence imaging, indocyanine green, fluorescence angiography, visceral surgery, tissue perfusion assessment, anastomosis, esophageal reconstruction, colorectal surgery, mesenteric ischemia, sentinel lymph node mapping, liver tumor detection, colorectal liver metastases, hemodynamic parameters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review