The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Application of Fluorescent Dyes in Visceral Surgery: State of the Art and Future Perspectives
Open accessAbstract
Background: Through the improvement and implementation of advanced intraoperative imaging, the indications for intraoperative fluorescence have spread to various fields of visceral surgery. Indocyanine green (ICG)-based fluorescence angiography and the imaging systems using this certain dye are currently the cornerstone of intraoperative, fluorescence-based medical imaging. Summary: The article focuses on principles and approaches of intraoperative fluorescence in general surgery. The current clinical practice of intraoperative fluorescence and its evidence are described. Emerging new fields of application are put in a perspective. Furthermore, the technique and possible pit-falls in the performance of intraoperative ICG fluorescence angiography are described in this review article. Key Messages: Overall growing evidence suggests that intraoperative fluorescence imaging delivers valuable additional information to the surgeon, which might help to perform surgery more exactly and reduce perioperative complications. Perfusion assessment can be a helpful tool when performing critical anastomoses. There is evidence from prospective and randomized trials for the benefit of intraoperative ICG fluorescence angiography during esophageal reconstruction, colorectal surgery, and surgery for mesenteric ischemia. Most studies suggest the administration of 2.5–10 mg of ICG. Standardized settings and documentation are essential. The benefit of ICG fluorescence imaging for gastrointestinal sentinel node detection and detection of liver tumors and colorectal metastases of the liver cannot clearly be estimated duo to the small number of prospective studies. Critical points in the use of intraoperative fluorescence imaging remain the low standardization and reproducibility of the results and the associated difficulty in comparing the results of the existing trials. Furthermore, little is known about the influence of hemodynamic parameters on the quantitative assessment of ICG fluorescence during surgery.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Already injured tissue can be estimated as optimally perfused by visual evaluation alone.
“Already injured tissue can be estimated as optimally perfused by visual evaluation alone. 172,176”
Hyperintensity due to capillary leakage and the resulting pooling of ICG in the tissue may lead to misinterpretation.
“Hyperintensity due to capillary leakage and the resulting pooling of ICG in the tissue may lead to misinterpretation.”
Citations
Cites
Karampinis, I., Keese, M., Jakob, J., Stasiunaitis, V., Gerken, A., Attenberger, U., Post, S., Kienle, P., & Nowak, K. (2018) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-018-3855-1 · Cited by 104
Self-citation
Flagged first, then by citations
Research works printed but not linked: 54
- 10.1007/s00464-016-5181-6 · DOI
- 10.1111/micc.12392 · DOI
- 10.1016/j.pdpdt.2019.10.007 · DOI
- 10.1002/bjs.10783 · DOI
- 10.1177/1457496919877581 · DOI
- 10.1117/1.JBO.21.8.080901 · DOI
- 10.1364/OL.41.001173 · DOI
- 10.1002/anie.200901916 · DOI
- 10.1038/nbt.1764 · DOI
- 10.1158/0008-5472.CAN-08-3116 · DOI
- 10.1016/j.athoracsur.2014.07.050 · DOI
- 10.1155/2012/940585 · DOI
- 10.1111/j.1600-0773.1998.tb01945.x · DOI
- 10.1039/C8PP00064F · DOI
- 10.1093/clinchem/33.6.765 · DOI
- 10.1152/jappl.1970.29.2.181 · DOI
- 10.1088/0031-9155/23/1/017 · DOI
- 10.1007/s00423-016-1400-9 · DOI
- 10.1007/s10151-017-1731-8 · DOI
- 10.1016/j.jamcollsurg.2014.09.015 · DOI
- 10.1002/bjs.10844 · DOI
- 10.1111/codi.14257 · DOI
- 10.1007/s00595-009-4140-4 · DOI · Paper page
- 10.1007/s00464-014-3592-9 · DOI
- 10.1007/s00464-018-6226-9 · DOI · Paper page
- 10.1111/j.1399-6576.2005.00834.x · DOI
- 10.1007/s00534-009-0160-0 · DOI
- 10.1007/s10877-017-0073-4 · DOI
- 10.1161/CIRCULATIONAHA.106.655936 · DOI
- 10.1097/SLA.0000000000000811 · DOI
- 10.1007/s00464-018-6503-7 · DOI
- 10.21037/jtd.2019.01.30 · DOI
- 10.1002/cncr.24291 · DOI
- 10.1007/s00268-010-0764-1 · DOI
- 10.1111/hpb.12057 · DOI
- 10.1002/cncr.28203 · DOI
- 10.1245/s10434-013-3360-4 · DOI
- 10.1007/s00464-013-3305-9 · DOI
- 10.1097/SLA.0000000000000775 · DOI
- 10.1007/s00432-016-2267-4 · DOI
- 10.1245/s10434-015-4801-z · DOI
- 10.1002/jso.24701 · DOI
- 10.23736/S0393-2249.17.02932-0 · DOI
- 10.1007/s10147-016-1064-z · DOI
- 10.1016/S1470-2045(18)30448-0 · DOI
- 10.6004/jnccn.2019.0001 · DOI
- 10.1159/000108323 · DOI
- 10.1007/s00464-011-1854-3 · DOI
- 10.1002/jso.24318 · DOI
- 10.3748/wjg.v25.i31.4502 · DOI
- 10.1016/j.jtcvs.2016.04.025 · DOI
- 10.1002/jso.25285 · DOI
- 10.1007/s10151-019-02107-6 · DOI
- 10.1016/S2468-1253(17)30395-3 · DOI
Cited by
Sorted by citations
Koelemay, M. J., Geelkerken, R. H., Kärkkäinen, J., Leone, N., Antoniou, G. A., de Bruin, J. L., Gombert, A., Gottsätter, A., Iborra, E., Ronchey, S., et al. (2025) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2025.06.010 · Cited by 123
Metadata
- Authors
- Nowak, K., Karampinis, I., & Gerken, A. L. H.
- Affiliations
- RoMed Kliniken (DE)
- University Medical Centre Mannheim (DE)
- Venue
- Visceral Medicine
- Publisher
- S. Karger AG
- Published
- 2020
- Volume
- 36
- Issue
- 2
- Pages
- 80-87
- ISSN
- 2297-4725 (ISSN-L)
- 2297-475X
- PMC
- PMC7184840
- OpenAlex
- W3013266050
- Cited by
- 32
- References
- 1
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 3 · 2022: 8 · 2021: 5 · 2020: 2
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Visceral Medicine (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- intraoperative fluorescence imaging, indocyanine green, fluorescence angiography, visceral surgery, tissue perfusion assessment, anastomosis, esophageal reconstruction, colorectal surgery, mesenteric ischemia, sentinel lymph node mapping, liver tumor detection, colorectal liver metastases, hemodynamic parameters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review