Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 476

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

2020 European Thyroid Association Clinical Practice Guideline for the Use of Image-Guided Ablation in Benign Thyroid Nodules

Open access
Papini, Enrico, Monpeyssen, Hervé, Frasoldati, Andrea, Hegedüs, Laszlo·2020·European Thyroid Journal

Abstract

Standard therapeutic approaches for benign thyroid lesions that warrant intervention are surgery for cold and either surgery or radioiodine for autonomously functioning thyroid nodules (AFTN). Image-guided thermal ablation (TA) procedures are increasingly proposed as therapy options for selected clinical conditions. Due to mounting scientific evidence and widening availability, ETA considered it appropriate to develop guidelines for the use of TA in adult patients. TA procedures are well tolerated, but a dedicated training of the operators is required and information on possible complications needs to be shared with the patients. The following factors should be considered when weighing between observation, surgery, and TA for benign thyroid nodules. In solid non-hyperfunctioning nodules, TA induces a decrease in thyroid nodule volume, paralleled by improvement in symptoms. Nodule re-growth is possible over time and may necessitate repeat treatment, or surgery, in a dialogue with the patient. In AFTN, radioactive iodine is the first-line treatment, but TA may be considered in young patients with small AFTN due to higher probability of restoring normal thyroid function and avoidance of irradiation. In cystic nodules, ethanol ablation (EA) is the most effective and least expensive treatment. TA may be considered for cystic lesions that relapse after EA or have a significant residual solid component following drainage and EA. TA should be restricted to benign lesions that cause symptoms or cosmetic concern. Presently, laser and radiofrequency ablation are the most thoroughly assessed techniques, with similar satisfactory clinical results. Microwaves and high-intensity focused ultrasound therapy options remain to be fully evaluated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000508484

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 476

Metadata

Authors
Papini, E., Monpeyssen, H., Frasoldati, A., & Hegedüs, L.
Venue
European Thyroid Journal
Published
2020
Volume
9
Issue
4
Pages
172-185
ISSN
  • 2235-0640 (ISSN-L)
  • 2235-0802
OpenAlex
W3035459951
Cited by
476
References
4
FWCI
37.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 2020 European Thyroid Association Clinical Practice Guideline for the Use of Image-Guided Ablation in Benign Thyroid Nodules. https://app.cochat.ai/papers/10.1159/000508484
The paper
Papini, E., Monpeyssen, H., Frasoldati, A., & Hegedüs, L. (2020). 2020 European Thyroid Association Clinical Practice Guideline for the Use of Image-Guided Ablation in Benign Thyroid Nodules. European Thyroid Journal. https://doi.org/10.1159/000508484

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.