Safety of Plasmapheresis in Donors with Low IgG Levels: Results of a Prospective, Controlled Multicentre Study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background and Objectives: Although plasmapheresis is generally considered safe, there are still concerns about the long-term effects of plasma donation on immunoglobulin G (IgG) levels. The aim of the present study was to investigate if there is a need to permanently defer donors who donated three times with an IgG level below 6.0 g/L. Study Design and Methods: From September 2007 to December 2017, adverse events (AEs) including infections were analysed from data of a prospective, controlled multicentre study of healthy volunteer donors, participating in an individualized plasmapheresis programme stratified by initial IgG level and body weight (individualized arm) or in standard plasmapheresis according to national guidelines (control arm). IgG was monitored at every fifth donation, and donors with IgG levels below the threshold were identified and followed up for possible AEs. Results: In total, 97,540 donations in 1,462 donors in the control arm and 1,491,223 donations in 14,281 donors in the individualized arm were included. Donation-based incidences of at least severe AEs and any infections were 0.019% and 0.192% in the control arm, and 0.014% and 0.153% in the individualized arm. Three or more IgG-measurements below the threshold occurred in 38.2% of control arm donors and 20.9% of individualized arm donors. There were no increased incidence rates of at least severe AEs or any infections in donors with ≥3 IgG-measurements below the threshold in either donor’s arm. Conclusions: Our data show no signs of compromised donor safety in donors with ≥3 IgG-measurements below the threshold, indicating that plasmapheresis is feasible and safe in these donors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A prospective Austrian cohort study found that donors with IgG below 700 mg/dL had a significantly higher rate of upper respiratory tract infections over 12 months compared to those with normal IgG”
From Potential Health Consequences of Regular Blood Donation: Current Evidence and Remaining Uncertainties (2026) · cites this paper as [15]
In the citing paper
“A single plasmapheresis session removing 750 mL of plasma extracts approximately 7–11 g of IgG, representing 5–10% of the total IgG pool”
From Potential Health Consequences of Regular Blood Donation: Current Evidence and Remaining Uncertainties (2026) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Burnouf, T. (2007) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2006.11.001 · Cited by 286
Frequency of immediate adverse effects associated with apheresis donation
McLeod, B. C., Price, T. H., Owen, H., Ciavarella, D., Sniecinski, I., Randels, M. J., & Smith, J. W. (1998) · Transfusion · doi:10.1046/j.1537-2995.1998.381098440858.x · Cited by 136 · cited 2×
“Donation-based incidence of severe systemic AEs was 0.036% [16].”
BackgroundResultInfluentialSchulzki, T., Seidel, K., Storch, H., Karges, H., Kiessig, S., Schneider, S., Taborski, U., Wolter, K., Steppat, D., Behm, E., et al. (2006) · Vox Sanguinis · doi:10.1111/j.1423-0410.2006.00794.x · Cited by 76 · cited 2×
“The Study on Intensified PLAsmapheresis analysed the safety of intensified donor plasmapheresis [3].”
BackgroundSelf-citationAdverse reactions in blood and apheresis donors: experience from two Italian transfusion centres.
(2009) · PubMed Central · doi:10.2450/2008.0018-08 · Cited by 69
Research works printed but not linked: 11
- 10.1056/NEJMra993360 · DOI · Paper page
- 10.1016/j.molimm.2004.07.046 · DOI
- 10.1016/j.transci.2019.102668 · DOI
- 10.1016/j.transci.2020.102931 · doi:10.1016/j.transci.2020.102931
- 10.1016/s0022-510x(99)00072-6 · DOI · Paper page
- 10.1016/j.tracli.2020.12.005 · DOI
- 10.1111/j.1537-2995.2007.01129.x · DOI
- 10.1111/j.1423-0410.2010.01446.x · DOI
- 10.1159/000357991 · DOI
- 10.1016/j.transci.2015.03.014 · DOI
- 10.1016/j.transci.2017.04.001 · DOI
Cited by
Warner, J. V., Drinkwater, M. J., Chu, G. J., Kelly, S., & McComish, J. S. (2025) · Vox Sanguinis · doi:10.1111/vox.13800 · Cited by 1
“…events, attributable to immunoglobulin or other protein depletion caused by plasma donation, even in individuals who regularly donate more than once per week or have recurrent immunoglobulin G (IgG) concentrations less than 6 g/L, have not been identified in prior publications [5, 16, 17].”
Berli, S., Kaiser, M. S., Schindler, E., & Tsakiris, D. A. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15176847
“A prospective Austrian cohort study found that donors with IgG below 700 mg/dL had a significantly higher rate of upper respiratory tract infections over 12 months compared to those with normal IgG [15].”
Metadata
- Authors
- Moog, R., Laitinen, T., & Taborski, U.
- ORCID
- Moog, Rainer
- Venue
- Transfusion Medicine and Hemotherapy
- Publisher
- S. Karger AG
- Published
- 2022
- Volume
- 49
- Issue
- 5
- Pages
- 271-279
- ISSN
- 1660-3796
- 1660-3818
- Cited by
- 11
- References
- 4
- Language
- en
- Licence
- creativecommons.org/licenses/by-nc/4.0/ (vor)
- creativecommons.org/licenses/by-nc/4.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.