Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Low molecular weight heparin for the prophylaxis of thromboembolism in women with prosthetic mechanical heart valves during pregnancy

Lee-Parritz, Aviva, Ansell, ack, Oran, Betul · 2004 · Thrombosis and Haemostasis

Abstract

Summary: Increased thromboembolic events occur in women with mechanical prosthetic valves during pregnancy, and selecting an effective and safe anticoagulant is still a challenge. Low molecular weight heparin (LMWH) is a promising alternative, but a recent warning and label change about its use in patients with mechanical prosthetic valves has caused confusion among physicians. The aim of the present study was to review the risks of maternal and fetal complications with mechanical heart valves treated with LMWH during pregnancy. We performed a review of the current medical literature through MEDLINE and EMBASE (1989 to 2004). Additional data sources included abstract proceedings, and reference lists of selected articles. Among 81 pregnancies in 75 women, the proportion of valve thrombosis was 8.64% (7/81; 95% CI, 2.52%–14.76%). The frequency of overall thromboembolic complication (TEC) was 12.35% (10/81; 95% CI, 5.19%–19.51%). Nine of ten patients with TEC received a fixed dose of LMWH and two of these received a fixed low dose of LMWH. Among 51 pregnancies whose anti-factor Xa levels were monitored, only one patient was reported to have a thromboembolic complication. The frequency of live births with LMWH was 87.65% (95%CI, 80.49%94.81%). In pregnant women with mechanical heart valves, LMWH appears to be a suitable option to a vitamin K antagonist. The use of LMWH warrants monitoring and appropriate dose adjustments to maintain a 4–6 hr post-injection anti-factor Xa level at a minimum of 1.0 U/ml to decrease the incidence of TEC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1160/th04-06-0337

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 178

Metadata

Authors
Lee-Parritz, A., Ansell, A., & Oran, B.
Venue
Thrombosis and Haemostasis
Published
2004
Volume
92
Issue
10
Pages
747-751
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W1977429432
Cited by
178
References
2
FWCI
4.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low molecular weight heparin for the prophylaxis of thromboembolism in women with prosthetic mechanical heart valves during pregnancy. https://app.cochat.ai/papers/10.1160/th04-06-0337
The paper
Lee-Parritz, A., Ansell, A., & Oran, B. (2004). Low molecular weight heparin for the prophylaxis of thromboembolism in women with prosthetic mechanical heart valves during pregnancy. Thrombosis and Haemostasis. https://doi.org/10.1160/th04-06-0337

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.