Medical literature, vena cava filters and evidence of efficacy: A descriptive review
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Up to 15% of all patients with venous thromboembolism (VTE) receive an inferior vena cava filter, and prophylactic placements are increasing. To determine whether current use of filters is based on robust evidence, a global review of the recent (2001–2012) literature on filters was undertaken. The MEDLINE database was searched for articles related to filters appearing during the period 2001–2012, updating a prior search of literature from 1975–2001. All retrieved articles were analysed, classified into predetermined categories and compared to the prior analysis; randomised and large (>100 patients with a filter) comparative non-randomised clinical studies were read in full. The 651 articles, vs 568 in the period 1975–2000, consisted mainly of retrospective series (37.8%), case reports (31.7%), reviews (14.7%, vs 6.7%, p<0.001), animal and/or in vitro studies (7.5%, vs 12.9%, p=0.002), and prospective series or trials (4.9%, vs 7.4%, p=0.07). Of 4 new randomised trials (RCT), none were designed to test the efficacy of the device; to date, only one RCT has attempted to ascertain efficacy, occurring during the period 1975–2000. Eleven large non-randomised studies compared clinical outcomes of patients with and without filters, in VTE patients (n=5) or prophylactic indications (n=6); two studies found statistically significant relationships between filter use and lower mortality rates, though none could demonstrate a causal relationship. Hence, the plethoric literature on filters parallels growing experience with these devices, but still fails to provide reliable evidence that filter use improves relevant clinical outcomes. No indication for filter placement is based on appropriate scientific evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kahn (2012) · doi:10.1378/chest.11-2296 · Cited by 2,693
Decousus, H., Leizorovicz, A., Parent, F., Page, Y., Tardy, B., Girard, P., Laporte, S., Faivre, R., Charbonnier, B., Barral, F.-G., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802123380701 · Cited by 1,702
Self-citationVena caval filters for the prevention of pulmonary embolism
Young, T., Tang, H., & Hughes, R. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006212.pub4 · Cited by 182
Cited by
Antithrombotic Therapy for VTE Disease
Kearon, C., Akl, E. A., Ornelas, J., Blaivas, A., Jimenez, D., Bounameaux, H., Huisman, M., King, C. S., Morris, T. A., Sood, N., et al. (2016) · Chest · doi:10.1016/j.chest.2015.11.026 · Cited by 4,830
Antithrombotic Therapy for VTE Disease
Stevens, S. M., Woller, S. C., Kreuziger, L. B., Bounameaux, H., Doerschug, K., Geersing, G.-J., Huisman, M. V., Kearon, C., King, C. S., Knighton, A. J., et al. (2021) · Chest · doi:10.1016/j.chest.2021.07.055 · Cited by 1,043
Jiang, J., Jiao, Y., & Zhang, X. (2017) · Phlebology: The Journal of Venous Disease · doi:10.1177/0268355516669004 · Cited by 10
Metadata
- Authors
- Meyer, G., Parent, F., Mismetti, P., & Girard, P.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2014
- Volume
- 111
- Issue
- 04
- Pages
- 761-769
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2103205431
- Cited by
- 36
- References
- 3
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical literature, vena cava filters and evidence of efficacy: A descriptive review. https://app.cochat.ai/papers/10.1160/th13-07-0601
- The paper
- Meyer, G., Parent, F., Mismetti, P., & Girard, P. (2014). Medical literature, vena cava filters and evidence of efficacy: A descriptive review. Thrombosis and Haemostasis. https://doi.org/10.1160/th13-07-0601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.