CoChat

Edoxaban: Impact on routine and specific coagulation assays: A practical laboratory guide

Chatelain, Bernard, Chatelain, Christian, Douxfils, Jonathan, Dogné, Jean-Michel, Mullier, François · 2016 · Thrombosis and Haemostasis
Cited by 75

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Summary: Assessment of plasma concentration/effect of edoxaban may be useful in some situations. Also, clinicians need to know how routine coagulation assays are influenced. It was our aim to determine coagulation tests useful for the assessment of edoxaban’s pharmacodynamics and provide recommendations for the interpretation of haemostasis diagnostic tests. Edoxaban was spiked at concentrations ranging from 0 to 1,000 ng/ml in platelet-poor plasma which covers the on-therapy range (from ± 25 ng/ml at Ctrough to ± 170 ng/ml at Cmax). aPTT, PT, dRVVT, chromogenic anti-Xa assays, TGA and a large panel of haemostasis diagnostic tests were performed using several reagents. A concentration-dependent prolongation of aPTT, PT and dRVVT was observed. The effect was dependent on the reagents. FXa chromogenic assays showed high sensitivity and a linear correlation depending on the methodology. TGA may be useful to assess the pharmacodynamics of edoxaban but its turnaround time and the lack of standardisation are limitations. Edoxaban impairs the assessment of lupus anticoagulant, protein S (clotting method), APC-R, antithrombin (FXa-based assay) and measurement of clotting factor activity. Immunological assays and assays acting below the FXa are not influenced by edoxaban. In conclusion, some PT reagents could be used to estimate edoxaban activity. Chromogenic anti-Xa assays are required to assess the plasma concentration. TGA may be useful but requires standardisation. In case of thrombophilia or in the exploration of a haemorrhagic event, immunological assays should be recommended, when applicable. Standardisation of the time between the last intake and the sampling is mandatory to provide a proper assessment of the result. Supplementary Material to this article is available online at www.thrombosis-online.com.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1160/th15-05-0415

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 75

Metadata

Authors
Chatelain, B., Chatelain, C., Douxfils, J., Dogné, J.-M., & Mullier, F.
Venue
Thrombosis and Haemostasis
Published
2016-03
Volume
115
Issue
02
Pages
368-381
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W2160030871
Cited by
75
References
6
FWCI
7.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Edoxaban: Impact on routine and specific coagulation assays: A practical laboratory guide. https://app.cochat.ai/papers/10.1160/th15-05-0415
The paper
Chatelain, B., Chatelain, C., Douxfils, J., Dogné, J.-M., & Mullier, F. (2016). Edoxaban: Impact on routine and specific coagulation assays: A practical laboratory guide. Thrombosis and Haemostasis. https://doi.org/10.1160/th15-05-0415

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.