Relationship Between Primary/Mechanical and Secondary/Biological Implant Stability
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: This systematic review was prepared as part of the Academy of Osseointegration (AO) 2018 Summit, held August 8-10 in Oak Brook Hills, Illinois, to assess the relationship between the primary (mechanical) and secondary (biological) implant stability. MATERIALS AND METHODS: Electronic and manual searches were conducted by two independent examiners in order to address the following issues. Meta-regression analyses explored the relationship between primary stability, as measured by insertion torque (IT) and implant stability quotient (ISQ), and secondary stability, by means of survival and peri-implant marginal bone loss (MBL). RESULTS: Overall, 37 articles were included for quantitative assessment. Of these, 17 reported on implant stability using only resonance frequncy analysis (RFA), 11 used only IT data, 7 used a combination of RFA and IT, and 2 used only the Periotest. The following findings were reached: ·Relationship between primary and secondary implant stability: Strong positive statistically significant relationship (P < .001). ·Relationship between primary stability by means of ISQ and implant survival: No statistically significant relationship (P = .4). ·Relationship between IT and implant survival: No statistically significant relationship (P = .2). ·Relationship between primary stability by means of ISQ unit and MBL: No statistically significant relationship (P = .9). ·Relationship between IT and MBL: Positive statistically significant relationship (P = .02). ·Accuracy of methods and devices to assess implant stability: Insufficient data to address this issue. CONCLUSION: Data suggest that primary/mechanical stability leads to more efficient achievement of secondary/biological stability, but the achievement of high primary stability might be detrimental for bone level stability. While current methods/devices for tracking implant stability over time can be clinically useful, a robust connection between existing stability metrics with implant survival remains inconclusive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gøtzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2012) · International Journal of Surgery · doi:10.1016/j.ijsu.2011.10.001 · Cited by 2,345
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Metadata
- Authors
- Monje, A., Ravidà, A., Wang, H.-L., Helms, J., & Brunski, J.
- Venue
- The International Journal of Oral & Maxillofacial Implants
- Publisher
- Quintessence Publishing
- Published
- 2019
- Volume
- 34
- Pages
- s7-s23
- ISSN
- 0882-2786 (ISSN-L)
- OpenAlex
- W2946329583
- Cited by
- 182
- References
- 3
- FWCI
- 16.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.