The DOI matches its Crossref record.
Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness.
Abstract
Recent intravascular ultrasound experience challenges the accuracy of ultrasonic measurement of arterial wall thickness. We reevaluated the correlation between histological and sonographic measurements of intima-media thickness using standard transcutaneous vascular technology. Carotid and femoral arterial segments were imaged before and after fixation using a 7-MHz linear-array vascular transducer. Log compression and beam orientation were varied. Mean intima, media, and adventitia thicknesses were measured and compared with corresponding histological tunica. Tissue processing caused 2.5% shrinkage. Intraobserver reading error was 0.7% for histology and 5.4% for sonography. Ultrasound overestimated the thickness of the intima and adventitia and underestimated the thickness of the media. For combined intima-media thickness, the differences between histology and imaging were insignificant, averaging 4% for the carotid artery and 9% for the femoral artery in the far-wall projection. In the near-wall projection, sonographic intima-media thickness was 20% less than that determined histologically. We conclude that ultrasonography is limited mainly by axial resolution in quantifying the dimensions of individual arterial tunica but is capable of accurately measuring far-wall intima-media thickness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stein, J. H., Korcarz, C. E., Hurst, R. T., Lonn, E., Kendall, C. B., Mohler, E. R., Najjar, S. S., Rembold, C. M., & Post, W. S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.11.011 · Cited by 2,429
Bots, M. L., Hoes, A. W., Koudstaal, P. J., Hofman, A., & Grobbee, D. E. (1997) · Circulation · doi:10.1161/01.cir.96.5.1432 · Cited by 2,345
Mintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Chambless, L. E., Heiss, G., Folsom, A. R., Rosamond, W., Szklo, M., Sharrett, A. R., & Clegg, L. X. (1997) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009302 · Cited by 1,990
Chambless, L. E., Folsom, A. R., Clegg, L. X., Sharrett, A. R., Shahar, E., Nieto, F. J., Rosamond, W. D., & Evans, G. (2000) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a010233 · Cited by 753
Metadata
- Authors
- Wong, M., Edelstein, J., Wollman, J., & Bond, M. G.
- Venue
- Arteriosclerosis and Thrombosis: A Journal of Vascular Biology
- Published
- 1993-04
- Volume
- 13
- Issue
- 4
- Pages
- 482-486
- ISSN
- 1049-8834 (ISSN-L)
- OpenAlex
- W2108685426
- Cited by
- 325
- References
- 0
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness. https://app.cochat.ai/papers/10.1161/01.atv.13.4.482
- The paper
- Wong, M., Edelstein, J., Wollman, J., & Bond, M. G. (1993). Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness. Arteriosclerosis and Thrombosis: A Journal of Vascular Biology. https://doi.org/10.1161/01.atv.13.4.482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.