Pooling in Chronic Orthostatic Intolerance: Arterial Vasoconstrictive but not Venous Compliance Defects
Abstract
Background — Orthostatic intolerance is characterized by postural tachycardia syndrome (POTS) with exaggerated tachycardia, orthostatic symptoms, and “pooling” (which comprises acrocyanosis and dependent edema when upright). My colleagues and I tested the hypothesis that pooling results from increased venous compliance in POTS patients. Methods and Results — Fifteen patients aged 13 to 19 years were compared with 11 healthy, age-matched controls. The POTS group was divided into patients with high venous pressure (P v >20 mm Hg) and normal P v on the basis of resting supine P v obtained in previous work. Subjects were studied using strain gauge plethysmography to measure blood flow, P v , and the venous compliance volume-pressure relation while supine and during incremental head-up tilt testing at −10°, 0°, 20°, and 35°. Volume-pressure relations of controls and POTS patients with normal P v and high P v were not different and were unchanged by orthostasis. Supine leg peripheral resistance was greater than control resistance in patients with high P v (54±9 versus 30±6 mm Hg · mL −1 · 100 mL −1 · min −1 ) and less than control resistance in patients with normal P v (17±2 mm Hg · mL −1 · 100 mL −1 · min −1 ). On upright tilt, resistance decreased in high P v to approximate resistance in normal P v . Resistance in controls increased throughout tilt. Leg P v increased in patients with normal P v and in controls but remained unchanged in the high P v group. Conclusions — The findings suggest that pooling in POTS is due to blunted arterial vasoconstriction, which produces passive redistribution of blood within peripheral venous capacitance beds. Venous compliance in POTS is similar to that in control subjects.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Acrocyanosis in POTS is not due to increased venous compliance but may be caused by decreased skin blood flow, possibly related to abnormal cutaneous nitric oxide activity.
“This acrocyanosis in POTS is not due to increased venous compliance [22;23] but may be caused by a decrease in blood flow to the skin, possibly related to abnormal cutaneous nitric oxide activity [24].”
From Postural tachycardia syndrome: beyond orthostatic intolerance (2015) · cites this paper as [23]
A dark red-blue discoloration of the legs (acrocyanosis) occurs with standing in about 50% of POTS patients.
“A dark red-blue discoloration of the legs might occur with standing, extending from the feet to above the knees in ∼50% of patients with POTS.”
From Postural tachycardia syndrome: beyond orthostatic intolerance (2015) · cites this paper as [23]
Pediatric patients with POTS had excessive pooling of blood in the lower extremities, primarily due to arteriolar dysregulation rather than inappropriately increased venous capacitance.
“Stewart et al. (14-17) noted that pediatric patients with POTS had excessive pooling of blood in the lower extremities, primarily due to arteriolar dysregulation rather than inappropriately increased venous capacitance.”
From Postural orthostatic tachycardia syndrome: mechanisms and new therapies (2020) · cites this paper as [14]
The citation lists haven’t been fetched yet
References 36 · Cited by 138
- Authors
- Stewart, J. M.
- Affiliations
- New York Medical College (US)
- Corresponding author
- Stewart, Julian M.
- ORCID
- Stewart, Julian M.
- Venue
- Circulation
- Published
- 2002-05-14
- Volume
- 105
- Issue
- 19
- Pages
- 2274-2281
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2168827569
- Cited by
- 138
- References
- 36
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 4 · 2019: 5 · 2018: 7 · 2017: 3 · 2016: 5 · 2015: 4 · 2014: 8 · 2013: 6 · 2012: 6
- FWCI
- 9.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r03ai045954-02)
- National Institute for Materials Science
- National Heart, Lung, and Blood Institute (R01HL066007, 1R01 HL66007)
- National Institute of Allergy and Infectious Diseases (1R03AI45954)
- Topics
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Keywords
- postural orthostatic tachycardia syndrome, orthostatic intolerance, pooling, venous compliance, venous pressure, arterial vasoconstriction, venous capacitance, head-up tilt, acrocyanosis, adolescents
- MeSH terms
- Adolescent, Adult, Arteries, Blood Pressure, Chronic Disease, Cyanosis, Edema, Electrocardiography, Female, Forearm, Heart Rate, Humans, Hypotension, Orthostatic, Leg, Male, Plethysmography, Posture, Reference Values, Regional Blood Flow, Syndrome, Tachycardia, Vasoconstriction, Veins, Tilt-Table Test
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review