CoChat

Effects of Ventricular Premature Stimulus Coupling Interval on Blood Pressure and Heart Rate Turbulence

Watanabe, Mari A., Marine, Joseph E., Sheldon, Robert, Josephson, Mark E. · 2002 · Circulation
Cited by 103

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background — Heart rate turbulence (HRT) is a promising noninvasive risk stratifier for mortality after myocardial infarction. On the basis of a study of ventricular premature complex coupling interval and sympathetic nerve burst amplitude, we hypothesized that measures of HRT would increase with increased prematurity of the coupling interval. Methods and Results — Twenty-eight patients undergoing programmed electrical stimulation were studied (12 with prior myocardial infarction, aged 60±18 years). An extrastimulus was delivered from the right ventricular apex after 20 sinus beats with a V-S 2 coupling interval decremented by 20 to 30 ms until refractoriness was reached. Turbulence slope (TS), turbulence timing (TT), and turbulence onset were calculated for each extrastimulus, and the linear regressions of these parameters on coupling interval and compensatory pause were calculated. Arterial blood pressure was measured with arterial catheter or a noninvasive continuous blood pressure transducer (Buffington cuff). TS and turbulence onset were abnormal in 4 and 13 patients, respectively. HRT parameters were significantly correlated with coupling interval or compensatory pause in only 2 or 3 patients for a given regression analysis. This absence of correlation was found likely to be due to lack of correlation between compensatory pause and systolic blood pressure after the compensatory pause. Heart rate and TS were correlated: Patients with high heart rate had low TS and late TT (TS=−2.7+0.01×sinus cycle length, P =0.018; TT=8.8 to 0.005×sinus cycle length, P =0.013). Conclusions — HRT can be induced by programmed stimulation. In this setting, heart rate affects HRT but not ventricular premature complex prematurity. Induced HRT seems to be a valid method for measuring HRT parameters in patients with few ventricular premature complexes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000022163.24831.b5

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 103

Metadata

Authors
Watanabe, M. A., Marine, J. E., Sheldon, R., & Josephson, M. E.
Venue
Circulation
Published
2002-07-16
Volume
106
Issue
3
Pages
325-330
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2148737912
Cited by
103
References
2
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Ventricular Premature Stimulus Coupling Interval on Blood Pressure and Heart Rate Turbulence. https://app.cochat.ai/papers/10.1161/01.cir.0000022163.24831.b5
The paper
Watanabe, M. A., Marine, J. E., Sheldon, R., & Josephson, M. E. (2002). Effects of Ventricular Premature Stimulus Coupling Interval on Blood Pressure and Heart Rate Turbulence. Circulation. https://doi.org/10.1161/01.cir.0000022163.24831.b5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.