Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record.

Low-Output, Low-Gradient Aortic Stenosis in Patients With Depressed Left Ventricular Systolic Function: The Clinical Utility of the Dobutamine Challenge in the Catheterization Laboratory

Nishimura, Rick A., Grantham, J. Aaron, Connolly, Heidi M., Schaff, Hartzell V., Higano, Stuart T., Holmes, David R.·2002·Circulation

Abstract

Background— Although aortic valve replacement can be performed at an acceptable risk level in selected patients with left ventricular systolic dysfunction and low-output, low-gradient aortic stenosis, not all patients presenting with these hemodynamics will benefit from the operation. Some patients may have only mild aortic stenosis, despite a small calculated valve area. We report on the clinical utility of diagnostic dobutamine stimulation during cardiac catheterization in these diagnostically challenging patients. Methods and Results— Thirty-two patients with low-output, low-gradient aortic stenosis and an ejection fraction <40% had dobutamine infusion in the catheterization laboratory. On the basis of the results of the dobutamine test, 21 patients underwent aortic valve replacement. All patients with a final aortic valve area ≤1.2 cm 2 at peak dobutamine infusion and a mean gradient of >30 mm Hg were found to have severe calcific aortic stenosis at operation. In the 15 patients in whom contractile reserve was identified during dobutamine challenge (increase in stroke volume >20%), 1 patient died perioperatively (7% mortality) and 12 patients were alive in New York Heart Association class I or II status at follow-up. Conclusions— In patients with left ventricular systolic dysfunction and aortic stenosis with a low output and a low mean gradient, dobutamine challenge may aid in selecting those who would benefit from an aortic valve operation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000025611.21140.34

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 324

Metadata

Authors
Nishimura, R. A., Grantham, J. A., Connolly, H. M., Schaff, H. V., Higano, S. T., & Holmes, D. R.
Venue
Circulation
Published
2002-08-13
Volume
106
Issue
7
Pages
809-813
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1986420755
Cited by
324
References
0
FWCI
5.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Output, Low-Gradient Aortic Stenosis in Patients With Depressed Left Ventricular Systolic Function: The Clinical Utility of the Dobutamine Challenge in the Catheterization Laboratory. https://app.cochat.ai/papers/10.1161/01.cir.0000025611.21140.34
The paper
Nishimura, R. A., Grantham, J. A., Connolly, H. M., Schaff, H. V., Higano, S. T., & Holmes, D. R. (2002). Low-Output, Low-Gradient Aortic Stenosis in Patients With Depressed Left Ventricular Systolic Function: The Clinical Utility of the Dobutamine Challenge in the Catheterization Laboratory. Circulation. https://doi.org/10.1161/01.cir.0000025611.21140.34

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.