Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record.

Inhaled Nitric Oxide as a Preoperative Test (INOP Test I): The INOP Test Study Group

Open access
Balzer, David T., Kort, Henry W., Day, Ronald W., Corneli, Howard M., Kovalchin, John P., Cannon, Bryan C., Kaine, Stephen F., Ivy, D. Dunbar, Webber, Steven A., Rothman, Abraham, Ross, Robert D., Aggarwal, Sanjeev, Takahashi, Masato, Waldman, J. Deane · 2002 · Circulation

Abstract

Background This study was performed to determine whether a preoperative hemodynamic evaluation with oxygen and inhaled nitric oxide identifies patients with pulmonary hypertension who are appropriate candidates for corrective cardiac surgery or transplantation more accurately than an evaluation with oxygen alone. Methods and Results At 10 institutions, 124 patients with heart disease and severe pulmonary hypertension underwent cardiac catheterization to determine operability. The ratio of pulmonary and systemic vascular resistance (Rp:Rs) was determined at baseline while breathing ∼21% to 30% oxygen, and in ∼100% oxygen and ∼100% oxygen with 10 to 80 parts per million nitric oxide to evaluate pulmonary vascular reactivity. Surgery was performed in 74 patients. Twelve patients died or developed right heart failure secondary to pulmonary hypertension following surgery. Rp:Rs<0.33 and a 20% decrease in Rp:Rs from baseline were chosen as 2 criteria for operability to determine, in retrospect, the efficacy of preoperative testing in patient selection. In comparison to an evaluation with oxygen alone, sensitivity (64% versus 97%) and accuracy (68% versus 90%) were increased by an evaluation with oxygen and nitric oxide when Rp:Rs<0.33 was used as the criterion for operability. Specificity was only 8% when a 20% decrease in Rp:Rs from baseline was used as the criterion for operability. Conclusion By using a combination of oxygen and inhaled nitric oxide, a greater number of appropriate candidates for corrective cardiac surgery or transplantation can be identified during preoperative testing when a specific value of Rp:Rs is used as a criterion for operability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000032875.55215.cb

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Balzer, D. T., Kort, H. W., Day, R. W., Corneli, H. M., Kovalchin, J. P., Cannon, B. C., Kaine, S. F., Ivy, D. D., Webber, S. A., Rothman, A., Ross, R. D., Aggarwal, S., Takahashi, M., & Waldman, J. D.
Venue
Circulation
Published
2002-09-24
Volume
106
Issue
12_suppl_1
Pages
I76-81
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1854121949
Cited by
160
References
0
FWCI
3.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inhaled Nitric Oxide as a Preoperative Test (INOP Test I): The INOP Test Study Group. https://app.cochat.ai/papers/10.1161/01.cir.0000032875.55215.cb
The paper
Balzer, D. T., Kort, H. W., Day, R. W., Corneli, H. M., Kovalchin, J. P., Cannon, B. C., Kaine, S. F., Ivy, D. D., Webber, S. A., Rothman, A., Ross, R. D., Aggarwal, S., Takahashi, M., & Waldman, J. D. (2002). Inhaled Nitric Oxide as a Preoperative Test (INOP Test I): The INOP Test Study Group. Circulation. https://doi.org/10.1161/01.cir.0000032875.55215.cb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.