Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record.

Electrical and Contractile Remodeling During the First Days of Atrial Fibrillation Go Hand in Hand

Open access
Schotten, Ulrich, Duytschaever, Mattias, Ausma, Jannie, Eijsbouts, Sabine, Neuberger, Hans-Ruprecht, Allessie, Maurits · 2003 · Circulation

Abstract

Background— The mechanisms of the atrial contractile dysfunction induced by atrial fibrillation (AF) are not completely understood. In particular, the relation between the atrial dysfunction and electrical remodeling has not yet been studied. Methods and Results— Seven goats were chronically instrumented with electrodes sutured to the atria and with ultrasonic piezoelectric crystals to record the atrial diameters. A pressure transducer was implanted in the right atrium. After 5 minutes, 3 hours, and throughout the first 5 days of artificially maintained AF, atrial contractile function was measured and the atrial effective refractory period (AERP) was monitored for comparison. Also, the positive inotropic effects of the L-type Ca 2+ -channel agonist BayY5959 and short trains of rapid atrial pacing were studied. After resumption of sinus rhythm, the recovery of atrial contractile function was followed. After 5 minutes of AF, atrial contractility was decreased by ≈55% but recovered completely within 10 minutes. Five days of AF nearly completely abolished the atrial contractile function, and recovery took 2 days. During the first days of AF, the development of the contractile dysfunction followed the same time course as the shortening of AERP (electrical remodeling). In remodeled atria, BayY5959 increased atrial contractility to the same extent as it prolonged AERP. The inotropic effect of short trains of rapid atrial pacing was similar in normal and remodeled atria. Conclusions— Depending on the duration of AF, different mechanisms contribute to the AF-induced atrial hypocontractility. Atrial contractile remodeling during several days of AF goes hand in hand with electrical remodeling and might be caused by a reduction of the L-type Ca 2+ -current.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000055314.10801.4f

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Schotten, U., Duytschaever, M., Ausma, J., Eijsbouts, S., Neuberger, H.-R., & Allessie, M.
Venue
Circulation
Published
2003-03-18
Volume
107
Issue
10
Pages
1433-1439
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2011419744
Cited by
179
References
0
FWCI
7.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical and Contractile Remodeling During the First Days of Atrial Fibrillation Go Hand in Hand. https://app.cochat.ai/papers/10.1161/01.cir.0000055314.10801.4f
The paper
Schotten, U., Duytschaever, M., Ausma, J., Eijsbouts, S., Neuberger, H.-R., & Allessie, M. (2003). Electrical and Contractile Remodeling During the First Days of Atrial Fibrillation Go Hand in Hand. Circulation. https://doi.org/10.1161/01.cir.0000055314.10801.4f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.